Specifications
Commom specifications
Model number
VZA@
Control methods
Output frequency range
Frequency tolerance
Resolution of frequency set value
Resolution of output frequency
Overload capability
Frequency set value
Braking torque
(short term peak torque)
V/f Characteristics
Inputs signals
Output signals
Standard functions
Analogue inputs
Braking/acceleration times
Display
Motor overload protection
Instantaneous overcurrent
Overload
Overvoltage
Undervoltage
Momentary power loss
Cooling fin overheat
Stall prevention level
Ground fault
Power charge indication
Degree of protection
Cooling
Ambient humidity
Storage temperature
Installation
Installation height
Vibration
V1000
Sine wave PWM (V/f control, sensorless current vector control)
Heavy duty use: 150% rated output current for one minute
Normal duty use: 120% rated output current for one minute
Short-term average deceleration torque: 150% (up 1.5 kW), 100% (for 1.5 kW), 50% (for 2.2 kW), 20% (fof bigger size)
Continous regenerative torque: Aprox 20% (125% with optional braking resistor, 10%ED, 10 s, braking transistor built itn)
Seven of the following input signals are selectable: Forward/reverse run (3-wire sequence), fault reset, external fault (NO/NC
contact input), multi-step speed operation, Jog command, accel/decel time select, external baseblock, speed search com-
mand, UP/DOWN command, accel/decel hold command, LOCAL/REMOTE selection, communication/control circuit terminal
selection, mergency stop fault, emergency stop alarm, self test
Following output signals are selectable (NO/NC contact output, 2 photo-coupler outputs): Fault, running, zero speed, speed
agree, frequency detection (output frequency <= or => set value), during overtorque detection, minor error, during baseblock,
operation mode, inverter run ready, during fault retry, during undervoltage detection, reverse running, during speed search,
Open-loop vector control, full-range automatic torque boost, slip compensation, 17-step speed operation (max.), restart after
momentary power loss, DC injection braking current at stop/start (50% of inverter rated current, 0.5 sec, or less), frequency
reference bias/gain, MEMOBUS communications (RS-485/422, max. 115K bps), fault retry, speed search, frequency upper/
lower limit setting, overtorque detection, frequency jump, accel/decel time switch, accel/decel prohibited, S-curve accel/decel,
Motor coasts to a stop at approx. 250% of inverter rated current
Heavy Duty: Motor coasts to a stop after 1 minute at 150% of inverter rated output current
Normal Duty: Motor coasts to a stop after 1 minute at 120% of inverter rated output current
Motor coasts to a stop if DC bus voltage exceed 410 V (double for 400 V class)
Stops when DC bus voltage is approx. 190 V or less (double for 400 V class)
Following items are selectable: not provided (stop if power loss is 15 ms or longer), continuous operation if power loss is
Stall prevention during acceleration/deceleration and constant speed operation
Protected by electronic circuit (operation level is approx. 250% of rated output current)
Cooling fan is provided for 200 V, 0.75 kW (1HP) (3/single-phase)
-20 ºC..+60 ºC (short-term temperature during transportation)
Up to 9.8 m/s
Specifications
0.1..400 Hz
Digital set value: ±0.01% (-10..+50 ºC)
Analogue set value: ±0.1% (25 ±10 ºC)
Digital set value: 0.01 Hz (<100 Hz), 0.1 Hz (>100 Hz)
Analogue set value: 1/1000 of maximum frequency
0.01 Hz
0..10 V (20 kΩ), 4..20 mA (250 Ω), 0..20 mA (250 Ω)
Pulse train input, frequency setting value (selectable)
Possible to program any V/f pattern
data output through communication.
PID control, energy-saving control, constant copy.
2 analogue inputs, 0..10 V, 4..20 mA, 0..20 mA
0.01..6000 s
Optionally frequency, current or set value
Error and status LED
Electronic thermal overload relay
(approx. 150 V or less for single-phase series)
approx. 0.5 s or shorter, continuous operation
Protected by thermister
Indicates until the main circuit voltage reaches 50 V.
IP20, NEMA1
400 V, 1.5 kW (2HP) (3-phase), others are self-cooling
95% RH or less (without condensation)
Indoor (no corrosive gas, dust, etc.)
Max. 1000 m
2
at 10 to less than 20 Hz, Up to 6.37 m/s
2
at 20 to 50 Hz
3