Omron F3UV Datasheet

Ultraviolet power monitor/illumination monitor
Hide thumbs Also See for F3UV:

Advertisement

Quick Links

Ultraviolet power monitor/illumination monitor
F3UV
Optical Fiber Type
Fiber Units
●UV Power Monitor
Heat resistance applications
Head can resist heat up to 300°C (using
F3UV-HM) Converts harmful ultraviolet
light into visible light
Case is made of ozone-proof and heatproof stainless steel
(SUS303).
UV light
F32-300, F32-70
F3UV-XW11/41, F3UV-XA
F3UV
Monitoring output state of UV (ultraviolet
light)/illumination light source
Features
Can be used as ultraviolet power monitor/illumination monitor
Visible light
Light receiving element in the
Amplifier does not deteriorates.
● During projection monitoring
Monitors projected light through fiber unit.
Illumination light
F32-300, F32-70
F3UV-XW11/41, F3UV-XA
Illumination light
A-215

Advertisement

Table of Contents
loading

Summary of Contents for Omron F3UV

  • Page 1 Heat resistance applications Head can resist heat up to 300°C (using F3UV-HM) Converts harmful ultraviolet Monitors projected light through fiber unit. light into visible light Case is made of ozone-proof and heatproof stainless steel (SUS303). Illumination light Illumination light UV light...
  • Page 2 Waterproof applications Head can resist heat up to 150°C (using F3UV-HM) Converts harmful ultraviolet light into visible light UV light Visible light Light receiving element in the Amplifier does not deteriorates. (Fiber unit not required) F3UV-XW11/41, F3UV-XA Application UV Cleaning: Detect liquid-crystal...
  • Page 3 7-segment digital % display Protective Structure to Prevent UV Deterio- ration. Easy teaching scheme A zinc die-cast case and synthetic quartz glass for the light receiving Button teaching is possible for zero-point setting and sensitiv- window. ity setting. Protective tubes and covers available as options.
  • Page 4: Ordering Information

    M4 screw *1. The values given are for a standard UV light source with a central wavelength of 360 nm, measured with a standard illumination meter (and for use in combination with the specified Amplifier and Head Unit). The power range is one for which teaching to 100% is possible.
  • Page 5: Main Unit

    Operating: 35% to 85% Storage: 35% to 95% Bending radius 24 ±5mm Tensile strength Gap between head connector/end cap and tube: 2 Nm or less, tube: 2 Nm or less Compression load Tube: 9.8 Nm (lateral pressure load) Head connector Brass nickel plating...
  • Page 6 *2. Response time: 10% to 90% of rise and fall time of analog output signal. *3. An analog output of up to 6 V (or 24 mA) can be output. The output is 1 V (or 4 mA) when there is no incident UV light.
  • Page 7 (with no icing or condensation) Ambient humidity Operating/Storage: 35% to 85% RH (with no icing or condensation) Vibration resistance 10 to 55 Hz, half amplitude of 0.75 mm or 100 m/s Shock resistance 500 m/s 5 m cable: approximately 170 g,...
  • Page 8 All F3UV Models When used as illumination monitor F3UV-HM F3UV-HT F3UV-A30 F3UV-A03 F3UV-XW series F3UV-XA – – Angle (degrees) Note: X-direction output fluctuation is ±10% F.S. 1,000 or less through 360° revolution Wavelength (nm) Wavelength (nm) A-222 Standard Photoelectric Sensors...
  • Page 9 Connected with controller Built-in Amplifier Type Analog Indications such as Voltage or Current Signals K3NX-VD2A-T1 UV power monitor F3UV-A30/A03 Black Brown Blue – Input/output stage circuit schematic Built-in Amplifier Type Optical Fiber Type F3UV-A30, F3UV-A03 F3UV-XA Power supply voltage Operation indicator...
  • Page 10: Part Names/Functions

    Calculates the light intensity integral value (I) from the Sensitivity adjustment Sensitivity can be set to the desired level with Light intensity inte- incident light intensity (P) and time (T) using the fol- function this one-turn adjuster. gration function (with...
  • Page 11: Operation

    If the analog output is 5.0 V or higher when the sensitivity con- ● F3UV-XW11/XW41 trol is set to MIN (all the way to the left), or if the analog output Basic Operating Procedures does not decrease when the sensor is moved away from the (1) Install the Amplifier Unit.
  • Page 12 Precautions Important Be sure to observe the precautions listed here. These precautions are essential for safe operation. (1) Do not disassemble, repair, or modify this product. (3) Do not install the amplifier unit in a location where it will be (2) Do not short-circuit the two ends of the load.
  • Page 13 "insertion mark" (dent) is attached. (F3UV-XA) Once a hole has been used to cut a fiber, do not use that hole again. The cut surface may not be clean enough and the detection characteristics may be degraded.
  • Page 14: Dimensions (Unit: Mm)

    15 dia. 7 dia. Head connector * 1 1,000 * 1. C3604 (Nickel-plated brass) * 2. Stainless steel (SUS304) Installed Protective Tube Note: M2 securing screws are included. Tube internal 16.4 35.5 diameter: 5 15 dia. 12 dia. 7 dia.
  • Page 15 RUN/ADJ/TEACH mode switch Measurement/teaching indicator (green/red) Operation indicator (orange) Fiber insertion opening 9.9 dia. 35.7 35.2 "Vinyl-insulated round cable of 5.8 dia. 7 cores conductor cross-sectional area: 0.2mm insulation diameter: 1.1mmStandard length: 2 m" Mounting Holes 2-M4 21 ± 89 ±...
  • Page 16 * 1. Material: Stainless steel (SUS303) Note: Heat resistance temperature is 300°C for part A and 110°C for part B (part inserted in unit). However, take care that parts inserted in unit (parts marked are within operating temperature range of amplifier.