Download Print this page

Omron F3S-B Series Datasheet page 5

Safety light curtain
Hide thumbs Also See for F3S-B Series:

Advertisement

Type
Accessories
Applicable standard
Note: 1 . For detailed type names and optical specifications, see „Type Naming Rule"
2 . Nominal value (set time). The accuracy is -0 ... +70% of the ON to OFF response time.
3 . Only with F3S-B###2P and BM###2P##.
4 . For the 1,050 mm protective height and longer types.
5 . Only with F3S-B###P# and BM##2P##.
Indicators
<Emitter Indicators>
Optical- axis
line mark
IR-power indicator
(Orange)
POWER
INTER-
Interlock indicator
LOCK
(Yellow)
EXT.TEST
BLANKING
External test /
blanking indicator
(Green)
Emitter
IR-power indicator:
Interlock indicator:
External test/ blanking indicator:
Receiver
ON-state indicator:
OFF-state indicator:
Instability indicator:
F3S-B
*1
F3S-B###P
Stand-alone
*3
Test rod
, mounting brackets (top and bottom), mounting brackets (intermediate)
*5
*5
plates
, Instruction manual
IEC(EN)61496-1 TYPE 2 ESPE (Electro-Sensitive Protective Equipment)
IEC 61496-2 TYPE 2 AOPD (Active Opto-electronic Protective Devices)
<Receiver Indicators>
ON
OFF
UNSTAB
Lit when emitting.
Lit during start/restart interlock or start interlock.
Lit during external test. / Flashing when using blanking function.
Lit when receiving light.
Lit with interrupted light.
Flashing during connection with F39-E1 or with failure.
Lit with an insufficient light reception or failure.
Flashing during connection with F39-E1.
*1
F3S-BM###P##
Master unit for series connection
ON-state indicator
(Green)
OFF-state indicator
(Red)
Instability indicator
(Orange)
*1
F3S-BS###
Slave unit for series connection
*4
, mounting
G-35

Advertisement

loading