Rating and Performance
Type
No. of optical axes
Optical-axis pitch
Optical resolution
(Detection capability)
Protective height
Detection distance
Response time
Startup waiting time
Supply voltage: Vs
Current
consumption
Light source
Effective aperture angle
Operating mode
Control output
Instability output
Protection circuit
Start/restart
interlock function
External test function
Relay monitoring
function (optional)
Start interlock function
(optional)
Blanking function
(optional)
Indicator
Connection method
Ambient temperature
Ambient humidity
Insulation resistance
Dielectric strength voltage
Degree of protection
Vibration resistance
Shock resistance
Materials
Size (cross section)
G-34
*1
F3S-B###P
Stand-alone
12 to 66
6 to 33
4 to 22
25 mm
50 mm
75 mm
Non-transparent: in diameter
30 mm
55 mm
80 mm
300 / 450 / 600 / 750 / 900 / 1,050 / 1,200 / 1,350 / 1,500 /
1,650 mm
0.3 to 5.0 m, up to 8 m on request
ON to OFF: See table "Response Time"
*2
OFF to ON
: Default 100 ms (selectable with F39-U1E, 80 to 400 ms)
2 s max.
24 VDC ± 20% (including 5 Vp-p ripple)
400 mA max. (under no-load conditions)
Infrared LED (880 nm wavelength). Lifetime: 50,000 hrs. at 25 °C.
Within ± 5° for the emitter and receiver at a detection distance of at least 3 m according to IEC
61496-2
Light ON
Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for volt-
age drop due to cable extension)
PNP transistor output (not safety-related control output),
activated during an insufficient light detection, failure detection and connection with F39-E1,
load current 100 mA max., residual voltage 2 V max. (except for voltage drop due to cable exten-
sion)
Output short-circuit protection, power supply reverse connection protection
Mode selection before power ON by connecting "Interlock selection input" line to:
Active: No connection or 0 to 2.5 VDC, 3 mA max.
Inactive: Instability output line
Reset of start/restart interlock by connecting "Interlock selection input" line to:
Interlock reset: 17 VDC to Vs, 20 mA max. Duration time 15 to 2,500 ms
Mode selection by connecting "External test input" line to:
Active: 17 VDC to Vs, 10 mA max. Duration time at least 15 ms
Inactive: No connection or 0 to 2.5 VDC, 2 mA max.
Default inactive, selectable with F39-U1E
Relay monitoring input line with NC contact connected,
Available level: 17 VDC to Vs, 10 mA max.
*3
Allowed relay delay time
: Selectable between 20 and 300 ms
Termination when not selected: No connection or 0 to 2.5 VDC, 2 mA max.
Default inactive, selectable with F39-U1E
Default inactive, selectable with F39-U1E
See "Indicators"
For Extension cable: 8 pins, M12 connector
For Series connection cable: 6 pins, M12 connector
During operation: –10 to 55 °C (with no freezing)
During storage: –25 to 70 °C
During operation: 35 to 85 %RH (with no condensation)
During storage: 35 to 95 %RH
20 MΩ min. (at 500 VDC)
1,000 VAC 50/60 Hz for 1 min
IEC60529 IP65
Normal operation: 10 to 55 Hz, double-amplitude: 0.7mm, X, Y and Z directions 20 sweeps
2
Normal operation: 100 m/s
Case: Aluminum
Front cover: PMMA (acrylic resin)
End caps: PA6
30 x 40 mm
*1
F3S-BM###P##
Master unit for series connection
12 to 66
6 to 33
4 to 22
25 mm
50 mm
75 mm
30 mm
55 mm
80 mm
[10 G], X, Y and Z directions: 1000 times
*1
F3S-BS###
Slave unit for series connection
12 to 30
6 to 15
4 to10
25 mm
50 mm
75 mm
30 mm
55 mm
80 mm
300 / 450 / 600 / 750 mm
No indicators