Page 1
Cod. Condensing Combi wall mounted boiler BRAVA SLIM HE 40 INSTALLATION AND SERVICING INSTRUCTIONS Gas Safety Certificate AS/NZS 4552 LN: SAI-400196 Watermark Certificate AS/NZS 3498 LN: WMK 26025 CAUTION This product must be installed exclusively by professionally qualified personnel in accordance with the requirements of the standards AS/NZS 5601, AS/NZS 3498, AS/NZS 3500.4, AS/NZS 3000, (current version) of the local gas, water and electricity...
Page 2
– Do not use electrical devices or appliances such as Dealer who sold the appliance. switches, electrical appliances etc if you can smell – The appliance must be used as intended by Sime fuel. If this should happen: who is not responsible for any damage caused to - open the doors and windows to air the room;...
Page 3
Brava Slim HE 40 e - (NATURAL GAS) 8112264 TABLE OF CONTENTS COMPLIANCE Our company declares that Brava Slim HE 40 boilers comply with DESCRIPTION OF THE APPLIANCE the following Australian Standards – AS/NZS 5601 Gas Installations TABLE OF CONTENTS –...
USING THE BOILER BRAVA SLIM HE 40 CAUTION Control panel – In accordance with AS/NZS 3498 a temperature control device such as a tempering valve must be fitted when hot water is supplied to sanitary fixtures used primarily for the purposes of personal hygiene –...
Preliminary checks Commissioning of the Brava Slim HE 40 boiler must be carried out by professionally qualified personnel after which the boiler can operate automatically. It may however be necessary for the User to start the appliance autonomously without involving a technician: for example, after a holiday.
– set the main system switch to "OFF" Fault / malfunction codes – close the gas valve. If a fault/malfunction is detected during boiler operation, the message “ALL” will appear on the display followed by the fault code (eg. “06” - no flame detected). If the message also appears, press and hold the button...
MAINTENANCE DISPOSAL Adjustments Disposal of the equipment (European Directive 2002/96/CE) For the appliance to operate correctly and efficiently it is Once it reaches the end of its operating life, the equipment recommended that the User calls upon the services of a MUST BE RECYCLED in line with current legislation.
HANDOVER INSTRUCTIONS N° Description When done Fill in all the details on this Boiler manual. Instruct the owner /users on the correct operation of the heating system, including how to turn the systems on and off, adjust the time and temperature settings. Instruct how to turn the heating system off in summer and on for winter.
Page 11
Service – 2 – Year 3 Date Service technician PIC Licence No. Name Service Company Contact phone number Work Completed Notes Service – 3 – Year 5 Date Service technician PIC Licence No. Name Service Company Contact phone number Work Completed Notes Service –...
Page 12
Service – 5 – Year 9 Date Service technician PIC Licence No. Name Service Company Contact phone number Work Completed Notes Service – 7 – Year 11 Date Service technician PIC Licence No. Name Service Company Contact phone number Work Completed Notes Service –...
Page 13
7.4.1 Brava Slim HE 40 i ......15 7.11 Wiring diagram ....... . 20 7.4.2...
Safety device may only be replaced by professional installation, protected against atmospheric agents. The main qualified personnel using Sime original spare parts. elements choices made by Sime for the Brava Slim HE 40 boilers are: – the total pre-mix microflame burner combined with a steel...
Structure 7.4.1 Brava Slim HE 40 i Heat exchanger bleed point Gas valve Heat exchanger Domestic hot water filter Combustion chamber door System relief valve Oversleeve Boiler drain Flame viewing window System pump Ignition/detection electrode Water pressure transducer Heat safety thermostat...
7.4.2 Brava Slim HE 40 e Heat exchanger bleed point Gas valve Heat exchanger Domestic hot water filter Combustion chamber door System relief valve Oversleeve Boiler drain Flame viewing window System pump Ignition/detection electrode Water pressure transducer Heat safety thermostat...
Technical features Brava Slim HE 40 DESCRIPTION 40 i 40 e CERTIFICATIONS Country of intended installation Fuel NATURAL GAS / UNIVERSAL LPG SAI GLOBAL number SAI-400196 Class NO 5 (< 70 mg/kWh) HEATING PERFORMANCE HEAT INPUT Nominal MJ/h Minimum MJ/h 28.0...
1137 1108 1079 1051 1024 100°C Expansion vessel The expansion vessel installed on the boilers has the following characteristics: Brava Slim HE 40 Description 40 i 40 e Total capacity 10.0 Prefilling pressure Useful capacity Maximum system content (*) Fig. 11 (*) Conditions of: Average maximum temperature of the system 85°C...
CAUTION 7.10 Control panel – In accordance with AS/NZS 3498 a temperature control device such as a tempering valve must be fitted when hot water is supplied to sanitary fixtures used primarily for the purposes of personal hygiene – pressing any one of these buttons for more than 30 seconds generates a fault on the display without preventing boiler operation.
7.11 Wiring diagram BLACK BLUE BROWN SAUX BLACK 4 3 2 1 BLACK BROWN BLUE 4 5 6 BROWN BLUE CN12 CN13 CN15 CN14 CN11 CD. 6324920 Line Auxiliary sensor SAUX Neutral Safety thermostat Fuse (3.15AT) Thermal fuse Ignition transformer Smoke flue gas probe System pump Flow meter...
INSTALLATION CAUTION Brava Slim HE 40 Description The appliance must be installed by the Sime Technical 40 i 40 e Service only, or by a qualified professional. W (mm) D (mm) H (mm) Receiving the product Weight (kg) 32.5 appliances are delivered in a single unit Brava Slim HE 40 protected by cardboard packaging.
For installation: and evacuation systems – remote the front panel (only on model Brava Slim HE 40 e ) – the electrical system has been manufactured in compliance – place the steel sheet template (2) (if supplied) on the wall (1) with specific Standards and by professionally qualified –...
The plumbing connections have the following characteristics compliance of the National or Local regulations in and dimensions. force. – Before commissioning the appliance, fill the siphon Brava Slim HE 40 i with water. 8.11 Gas supply boilers leave the factory prearranged for gas...
8.12 Connecting the flue 8.12.1 Flue Terminal Positions Door Fig. 23 Brava Slim HE 40 DESCRIPTION Min. Clearance (mm) Flue terminal Mechanical air inlet Gas meter Electricity meter of fuse box Shaded area indicates prohibited area Below eaves, balconies and other projections (Appliances over 50MJ/h)
Coaxial duct kit 8096250 8096253 boiler. Extension W. 1000 mm 8096150 8096171 8.12.3 Brava Slim HE 40 i Extension W. 500 mm 8096151 8096170 Vertical extension W. 140 mm Permitted outlets with smoke analysis take-off 8086950 point Adapter for Ø...
To facilitate introduction of the connection wires of the optional components into the boiler: – disassemble the smoke outlet duct of the Brava Slim HE 40 e – remove the screws (1), pull the front panel (2) forwards and release it from the top by lifting it Ø...
– remove the screws (3) securing the control panel (4) CAUTION – move the panel (4) upwards (a) but keeping it in the side It is compulsory: guides (5) to the end of travel – to use an omnipolar cut-off switch, disconnect –...
8.13.2 Chrono-thermostat or Air Thermostat MULTI ZONE system - with zone valve, air thermostat and external sensor. The electrical connection of the chrono-thermostat or air thermostat has already been described. When fitting the component in the room where the readings are to be taken, follow the instructions provided with the device.
Remove the front panel: the correct pressure reading appears – disassemble the smoke outlet duct of the Brava Slim HE 40 e – close the automatic bleed valve (3) – remove the two screws (1), pull the front panel (2) forwards –...
COMMISSIONING Preliminary operations Before commissioning the appliance, check that: – the type of gas is correct for the appliance – the gas isolation valves for the heating system and the water system are open – the pump impeller rotates freely –...
– once the required parameter has been reached, press the Parameter setting and display to modify the value within the permitted range. buttons > < To go into the parameter menu: The modifications are stored automatically. – from the selected mode (eg. WINTER) When all the parameter modifications have been made, exit the –...
Type Description Self-calibrating procedure is required Incorrect positioning of the delivery sensor EV2 SGV current max/min absolute limits error EV2 SGV current upper limit error EV2 SGV current lower limit error Fault on the valve control logic line/valve cable damaged Block due combustion during start-up –...
This function lasts 15 minutes and is activated by proceeding as follows: – disassemble the smoke outlet duct of the Brava Slim HE 40 e , if not already removed – if the panel (2) has not already been removed, remove the...
Gas conversion to exit the "Chimney sweeper – press the button models can work with NATURAL GAS Brava Slim HE 40 Procedure”. The boiler water delivery temperature will or UNIVERSAL LPG without the need for any mechanical appear on the display conversion.
Professionally Qualified Technician to carry out BI-ANNUAL To access the internal parts of the boiler: maintenance. – disassemble the smoke outlet duct of the Brava Slim HE 40 e – remove the screws (1), pull the front panel (2) forwards and CAUTION...
– loosen the clips (6) and extract the air inlet pipe (7) CAUTION – unscrew the swivel joint (8) Work carefully when removing the assembly (13) to – extract the connectors (9) from the fan and disconnect the prevent any damage occurring to the internal insulation electrode cable (10) of the combustion chamber and the door seal.
10.5 Unscheduled maintenance Type Fault Solution - Check PAR 02 "hydraulic If replacing the electronic board , the user MUST set the configuration" parameters as indicated in the table. Auxiliary sensor fault - Check the electrical Setting for Brava connection Slim HE 40 Gas valve modulator - Check the electrical...
Page 40
Type Fault Solution Internal error - Contact the Technical (board component Assistance Centre protection) Unstable combustion - Contact the Technical feedback signal error Assistance Centre Combustion set - Contact the Technical cannot be reached Assistance Centre error System has reached maximum air - Contact the Technical correction error (at...
11 COMMISSIONING BOILER CHECKLIST A suggested method of commissioning the boiler; the actual method can vary according to the boiler make, type and installation. The boiler must always be installed and commissioned by an approved gas technician. The installer certifies that this Boiler has been installed to the manufacturer's instructions, has been filled, commissioned and is ready for use.
Page 44
- Brava Slim HE 40 e Brava Slim HE 40 i...
Page 45
- Brava Slim HE 40 e Brava Slim HE 40 i...
Page 46
- Brava Slim HE 40 e Brava Slim HE 40 i...
Page 47
BRAVA SLIM BRAVA SLIM Pos. Code Description Pos. Code Description 40 i 40 e 40 i 40 e 6264565 Boiler fixing bracket 6226619 Spring for heat exchanger connection 6010894 Support exchangers bracket 2030267 Piracriten gasket Ø 30x17x2 6147412 Plug for air vent connection 6226638 Divertor valve motor spring clip 6226464 O-ring 115 diam.
13.1.1 Front panel To access the internal parts of the boiler: – disassemble the smoke outlet duct of the Brava Slim HE 40 e – remove the screws (1), pull the front panel (2) forwards and release it from the top by lifting it Fig.
13.3.2 Domestic hot water sensor 13.3 Remove/replace sensor and thermostat – Remove front panel (see "Remove panels" on page 48) – move the control panel (A) into a horizontal position (see " 13.3.1 Smoke flue gas probe Rotate control panel" on page 48) –...
13.4 Remove electronic board 13.5 Remove/replace combustion head unit and – Remove front panel (see "Remove panels" on page 48) – Remove front panel (see "Remove panels" on page 48) – move the control panel (A) into a horizontal position (see " –...
– unscrew the screws (6) and unthread the combustion head (7) 13.6 Remove/replace the ignition and flame – unscrew the screws (8) and remove the fan (9) detection electrode – Remove front panel (see "Remove panels" on page 48) – disconnect the connectors (1) and (2) Fig.
13.7 Remove/replace the siphon 13.8 Remove/replace gas valve – Close the gas valve CAUTION – remove the front panel (see "Remove panels" on page 48) – move the control panel (A) into a horizontal position (see " When disassembling, some residual water may leak. Rotate control panel"...
13.9 Remove/replace the expansion vessel 13.10 Remove/replace diverter valve – Shut-off the valves to the system and empty the boiler – Shut-off the valves to the system and empty the boiler – remove the front panel (see "Remove panels" on page 48) –...
13.11 Remove/replace system pump 13.12 Remove/replace domestic water exchanger – Shut-off the valves to the system and empty the boiler – remove the front panel (see "Remove panels" on page 48) CAUTION – lift the connector (1) using a screwdriver (2) If it is easier to remove the pump, follow the instructions of point "Remove/replace system pump"...