Advertisement

Specifications of Expansion I/O Units and Expansion Units

Expandable CPU Units

• Expansion I/O Units and Expansion Units cannot be connected to E10/14/20 or N14/20 CPU Units.
• A total of up to three Expansion I/O Units and Expansion Units can be connected to an E30/40, N30/40/60 or NA20 CPU Unit.
●CP1E E10/14/20 or N14/20 CPU Unit
●CP1E E30/40, N30/40/60 or NA20 CPU Unit

Connection Methods

Connection cables for the Expansion I/O Units and Expansion Units are used to connect the Units. The length can be extended by using a CP1W-
CN811 I/O Connection Cable (length: 800 m).
Maximum Number of I/O Points for an Expanded System
Built-in I/O on CPU Unit
CPU Unit
Number of
Total
CP1E-E10D@-@
10
6
CP1E-@14D@-@
14
8
CP1E-@20D@-@
20
12
CP1E-@30D@-@
30
18
CP1E-@40D@-@
40
24
CP1E-N60D@-@
60
36
CP1E-NA20D@-@ 20
12
Restrictions on External Power Supply Capacity
The following restrictions apply when using the CPU Unit's external power supply.
●AC-power-supply E30/40, N30/40/60 or NA20 CPU Unit
The power supply capacity is restricted for AC-power-supply E30/40, N30/40/60 or NA20 CPU Units. It may not be possible to use the full 300 mA
of the external power supply, though a CPU Unit can connect any CP-series Expansion I/O Unit or Expansion Unit.
The entire 300 mA from the external power supply can be used if Expansion Units and Expansion I/O Units are not connected.
Refer to the CP1E CPU Unit Hardware Manual (Cat. No. W479) for details.
●AC-power-supply or DC-power-supply E10/14/20, N14/20 CPU Unit
There is no external power supply on AC-power-supply or DC-power-supply E10/14/20, N14/20 CPU Units.
CP1E-E@@D@-@ CP1E-N@@D@-@/NA20D@-@
A total of up to three CP-series Expansion I/O Units
and Expansion Units can be connected.
NC
NC
COM
01
03
05
07
09
11
01
03
NC
NC
00
02
04
06
08
10
00
02
CH
CH
CH
IN
00
01
02
03
04
05
06
07
08
09
10
11
CH
00
01
02
03
04
05
06
07
08
09
10
11
CH
OUT
00
01
02
03
04
05
06
07
CH
00
01
02
03
04
05
06
07
CH
CH
NC
00
01
02
04
05
07
00
02
04
NC
COM
COM
COM
03
COM
06
COM
01
03
COM
Built-in Analog
Number of
AD
inputs
outputs
4
6
8
None
None
12
16
24
8
2
1
CP-series Expansion Units and Expansion I/O
Units cannot be connected.
05
07
09
11
NC
NC
COM
01
03
05
07
09
11
01
03
05
07
09
11
04
06
08
10
NC
NC
00
02
04
06
08
10
00
02
04
06
08
10
CH
CH
CH
IN
00
01
02
03
04
05
06
07
08
09
10
11
CH
00
01
02
03
04
05
06
07
08
09
10
11
CH
OUT
00
01
02
03
04
05
06
07
40EDR
CH
40EDR
00
01
02
03
04
05
06
07
EXP
CH
CH
EXP
05
07
NC
00
01
02
04
05
07
00
02
04
05
07
06
NC
COM
COM
COM
03
COM
06
COM
01
03
COM
06
Total number of
Expansion I/O Units and
Expansion Units that can
be connected
DA
Not possible.
3 Units maximum
NC
NC
COM
01
03
05
07
09
11
01
03
05
07
09
11
NC
NC
00
02
04
06
08
10
00
02
04
06
08
10
CH
CH
CH
IN
00
01
02
03
04
05
06
07
08
09
10
11
CH
00
01
02
03
04
05
06
07
08
09
10
11
CH
OUT
00
01
02
03
04
05
06
07
CH
40EDR
00
01
02
03
04
05
06
07
CH
CH
EXP
NC
00
01
02
04
05
07
00
02
04
05
07
NC
COM
COM
COM
03
COM
06
COM
01
03
COM
06
Number of inputs: 24
Number of outputs: 16
Total number of I/O points when three CP1W-40ED@
Expansion I/O Units are connected
Number of
Total
inputs
10
6
14
8
20
12
150
90
160
96
180
108
140
84
Number of
outputs
4
6
8
60
64
72
56
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents