CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main fuse
box before starting and during the installation.
INSTALLATION INSTRUCTIONS
Model 15810R
Model 15811R
Model 15839R
Model 15850R
Model 15870R
Model 15878
Model 15880
Model 16120
Model 16121
Model 16125
SAFETY INSTRUCTIONS
READ THESE INSTRUCTIONS FIRST.
SAVE FOR FUTURE REFERENCE.
This fixture is intended for installation in accordance with
the National Electric Code (NEC) and Local code specifica-
tions. Failure to adhere to these codes and instructions
may result in serious injury and/or property damage and
will void the warranty.
1)
WARNING - Risk of Electric Shock. Install all luminaires 10 feet
(3.05 m) or more from a pool, spa, or fountain.
2)
This fixture is to be used only with a power unit (transformer)
rated a maximum of 300 W (25 AMPS) 15 volts.
3)
18 GA wire is not intended for direct burial and should not be
buried except for a maximum 6 inches (15.2 cm) in order to
connect to the main low voltage cable.
Wire routing should be in close proximity to the luminaire or
fitting, or next to a building structure such as a house or deck.
4)
Direct burial rated wire is to be buried a minimum of 6"
(152mm) beneath the surface of the ground.
NOTE: If additional Direct Burial wire is needed, contact your
local Kichler
landscape distributor.
®
• 8 GA wire can be purchased in length of 250' (76 M), 15503-BK.
• 10 GA wire can be purchased in length of 250' (76 M),
15504-BK.
• 12 GA wire can be purchased in lengths of 100' (30 M),
15501-BK; 250' (76 M), 15502-BK; 500' (152M), 15505-BK; and
1000' (304 M), 15506-BK.
5)
Wiring connections must be made with approved/listed wire
connection device(s) suitable for the application. Do not exceed
manufacturers' wiring combination specifications for size and
quantity of conductors.
Connection should be made within 6 inches (15.2 cm) from a
building structure, a luminaire, or fitting
CAUTION
WHEN INSTALLING KICHLER LANDSCAPE LIGHTING (LINE VOLTAGE
OR LOW VOLTAGE), CARE SHOULD BE TAKEN TO KEEP CLEAR OF
POTENTIALLY COMBUSTIBLE MATERIALS.
WHEN MAINTAINING THE FIXTURES, BE SURE TO REMOVE LEAVES,
PINE NEEDLES, GRASS CLIPPINGS, MULCH, OR ANY DEBRIS THAT
HAS ACCUMULATED ON THE LIGHT BULB, LENS, OR BODY OF THE
FIXTURE.
ASSEMBLY AND INSTALLATION
1)
Determine desired location for mounting fixture.
2)
At desired location, hammer stake (A) into ground. To avoid
damage to stake, place a board on top of stake while hammering.
If ground is hard and stake is difficult to install, make a crosscut
in ground using a flat shovel.
3)
Clear away area in ground at wireway slot (B) in top of stake
(A).
4)
Lay 12V cable into wireway slot (B) and screw stem (C) into
stake (A). If assembly does not look straight, adjust by pushing
or pulling on stake only.
5)
Screw shade (D) onto stem (C).
6)
Make wire connections using supplied wire nuts following
instructions on bag.
KICHLER.COM/CUSTOMER-CARE/WARRANTY-INFORMATION/LANDSCAPE-WARRANTY
FOR WARRANTY INFORMATION PLEASE VISIT:
We're here to help
D
C
B
A
866-558-5706
Hrs: M-F 9am to 5pm EST
IS-15810R-US
Need help?
Do you have a question about the 15810R and is the answer not in the manual?
Questions and answers