  • Page 1 www.sparkfabrica.com CHANGSHA SPARK TECHNOLOGY ELECTRONICS CO.,LTD SPARK SPIN SF-X2 USER MANUAL SPARK SPIN USER MANUAL SF-X2...
  • Page 2: Table Of Contents

    CONTENTS 1 PRODUCTINTRODUCTION 1.1 PRODUCT OVERVIEW 1.2 PRODUCT ACCESSORIES 1.3 SPARK FABRICA GRANULE 2 TECHNICAL PARAMETER 3 ON-SCREEN OPERATING INSTRUCTIONS 3.1 BACK PANELINTRODUCTION 3.2 MENU SETTING 3.3 STATUS ICONS 3.4 DMX PARAMETER LIST 3.41 DMX 2 channel mode 3.42 DMX 4 channel mode 4 PRECAUTIONS FOR OPERATION 4.1 ENVIRONMENTAL REQUIREMENTS...
  • Page 3 Please read the manual carefully before installing and using this product. Failure to read or comply with this manual may result in injury to products and personnel, and Spark Fabrica shall not be responsible for this. This product is a professional machine, we do not assume any responsibility for accidents or losses caused by the use or maintenance of this product by personnel without professional training and permission.
  • Page 4: Productintroduction

    www.sparkfabrica.com CHANGSHA SPARK TECHNOLOGY ELECTRONICS CO.,LTD 1 PRODUCT INTRODUCTION This product is a special effects device. For professional use only. This product is a special effects device for the dynamic and static simulation of cold pyrotechnics. Using CST technology, the tailor-made metal powder is heated to produce a dynamic and static fountain of silver sparks, which is safer than traditional cold fireworks.
  • Page 5: Product Accessories

    A Kind Of Special Metal Powder With Full Spark And Less Residue, No Smoke, No Odor And No Toxic Gas During Use Only the consumables provided by Spark Fabrica are allowed to be used. Spark Fabrica shall not be liable for any machine breakdown,personal injury and property loss caused by the use of consumables not provided by the company.
  • Page 6: Technical Parameter

    Software Upgrade Box Optional 120ohms Terminal Resistance Optional √ Certification ROHS √ Net Weight 22kg Weight Gross Weight 25kg Machine Dimensions - L*W*H 319mm*320mm*404mm Dimensions Packing Dimensions - L*W*H 450mm*425mm*475mm Granule Granule Spark Fabrica Granule SPARK SPIN USER MANUAL SF-X2 |...
  • Page 7: On-Screen Operating Instructions

    www.sparkfabrica.com CHANGSHA SPARK TECHNOLOGY ELECTRONICS CO.,LTD ON-SCREEN OPERATING INSTRUCTIONS BACK PANEL INTRODUCTION SWIPE CARD Swipe Card Area This area for the RFID card can increase the specific working time of a single machine. RFID card is supplied with consumables. It is a secure design that allows the machine to identify the parameters and types of consumables.
  • Page 8: Menu Setting

    www.sparkfabrica.com CHANGSHA SPARK TECHNOLOGY ELECTRONICS CO.,LTD 3.2 MENU SETTING Temperature 400℃-800℃ DMX Channel DMX Address 1-512 Safety Address Maximum / Moderate Density / Minimum Match Remote OFF/ON RFID OFF/ON Auto Heat OFF/ON Tilt Sensor OFF/ON TFT BackLight OFF/ON MENU SETTING Restore Defaults OFF/ON Ta:xxxxx,FM1:XXX,FM2:XXX, TA:X...
  • Page 9: Status Icons

    www.sparkfabrica.com CHANGSHA SPARK TECHNOLOGY ELECTRONICS CO.,LTD 3.3 STATUS ICONS When the icons are all green,it indicates normal operation and when the icons are NOTICE yellow,it indicates an abnormality. Chip Temperature Blower Motor Shaft Motor Tilt Sensor Hopper Motor PCB Temperature Temp.
  • Page 10: Dmx 4 Channel Mode

    www.sparkfabrica.com CHANGSHA SPARK TECHNOLOGY ELECTRONICS CO.,LTD 3.42 DMX 4 channel mode FIRST CHANNEL (NOZZLE 1) FUNCTION 0-15 Nozzle 1 Fountain OFF 16-255 Nozzle 1 Fountain ON( height adjustable) SECOND CHANNEL (HEATING/CLEAR MATERIAL/EMERGENCY STOP) FUNCTION 11-39 Emergency Stop 56-200 Clear Material (perform after each show) 240-255 Preheat On ((disabled when auto-heat ON) THIRD CHANNEL (NOZZLE 2)
  • Page 11: Safety Tips

    www.sparkfabrica.com CHANGSHA SPARK TECHNOLOGY ELECTRONICS CO.,LTD 4.2 SAFETY TIPS Make sure to connect the ground wire properly to avoid electric shock. If water enters or covers the bottom of the machine, it will cause machine to malfunc- tion or electrical leakage. Make sure that the bottom of the machine is far enough away from the impounded surface water on rainy days, so as to prevent the water from entering the inside of the machine Do not touch sparks.
  • Page 12: Operate The Machine

    www.sparkfabrica.com CHANGSHA SPARK TECHNOLOGY ELECTRONICS CO.,LTD OPERATE THE MACHINE 5.1 PREPARATIONS Place machines on a firm and level ground, with a recommended maximum tilt angle of 15 degrees or less. Keep people or flammable materials at least 10 feet (3 meters) away from the machine, and make sure that debris does not fall on flammable objects.
  • Page 13: Machine Connection

    www.sparkfabrica.com CHANGSHA SPARK TECHNOLOGY ELECTRONICS CO.,LTD Please pour the consumables into the feeder at the top of the machine with the power off. Please wear safety glasses when adding consumables or testing the machine to prevent eye injury. 5.3 MACHINE CONNECTION Power supply connection and DMX signal cables connection *Get the first unit plugged in *Connect the other machines in parallel with power connection cables.
  • Page 14: Initial Setting

    www.sparkfabrica.com CHANGSHA SPARK TECHNOLOGY ELECTRONICS CO.,LTD Do not use damaged power plugs and power connecting cords. 1 power plug is recommended to connect up to 4 units of this product in parallel at most. Please calculate the total current of all machines in accordance with the power supply and safety parameters of the product.
  • Page 15: Dmx Address Setting

    www.sparkfabrica.com CHANGSHA SPARK TECHNOLOGY ELECTRONICS CO.,LTD The sparking temperature of the machine is the factory default. The automatic heating function will be automatically turned on if the DMX signal is not connected, but it can be set to on or off. For details, please refer to 3.2 Menu Settings. When connected to the DMX signal, the machine can only be heated by turning on the heating function on the host controller.
  • Page 16: Start To Spark

    www.sparkfabrica.com CHANGSHA SPARK TECHNOLOGY ELECTRONICS CO.,LTD START TO SPARK The spark machine can be controlled by the dedicated host controller or a DMX512 console 5.6.1 POWER ON THE CONSOLE 5.6.2 TURN ON THE HEATING FUNCTION The DMX value for the heating function of the second channel is 240~255, and it takes about 5 minutes to preheat after power on.
  • Page 17: Use The Remote Controller To Control The Sparking

    www.sparkfabrica.com CHANGSHA SPARK TECHNOLOGY ELECTRONICS CO.,LTD If affected by the wind, the height of the sparks will be reduced and the direction of that will also be tilted. Suitable fire extinguishers are as follows: 3.Any items similar to sand or soil can be used to cover and put out the fire. 4.Please use Class D Fire extinguishers for metal materials on fire.
  • Page 18: Clean Machine

    www.sparkfabrica.com CHANGSHA SPARK TECHNOLOGY ELECTRONICS CO.,LTD 5.7 CLEAR MATERIAL This product offers the function of clearing material, which can clean the consumables that have been heated but not ejected. It may prevent the machine from being stuck by clogging in the combustion chamber effectively. Clearing material is the function of the second channel.
  • Page 19: Failure Handling

    www.sparkfabrica.com CHANGSHA SPARK TECHNOLOGY ELECTRONICS CO.,LTD 7 FAILURE HANDLING ERROR CODE DESCRIPTION SOLUTION System Error System Error: Replace main board E0 Storage Fail StorageFail 1.Restart machine to clear alerts,stop operating for 15 minutes until temperature returns to normal. Blower motor protection/ Motor Protect 2.Check wire connection of motor disconnected...