Nordson ARAG VISIO 4670610 Installation - Use - Maintenance

Nordson ARAG VISIO 4670610 Installation - Use - Maintenance

Double volume counter version

Advertisement

Quick Links

DOUBLE VOLUME COUNTER VERSION
4670610
Software rel. 2.6.x
INSTALLATION, USE AND MAINTENANCE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ARAG VISIO 4670610 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Nordson ARAG VISIO 4670610

  • Page 1 DOUBLE VOLUME COUNTER VERSION 4670610 Software rel. 2.6.x INSTALLATION, USE AND MAINTENANCE...
  • Page 2 ● LEGEND OF SYMBOLS = Generic danger = Warning MODE CAN BE ACTIVATED BY SELECTING CONT. VOLUME (II) SETUP MENU > OPTIONS > OPERATING MODE FROM This manual is an integral part of the equipment to which it refers and must accompany the equipment in case of sale or change of ownership.
  • Page 3: Table Of Contents

    • SUMMARY 1 INTRODUCTION ......4 9.3 OPTIONS ..........15 1.1 PRODUCT DESCRIPTION ....... 4 9.3.1 Language ........... 15 9.3.2 Units of measurement ....... 16 2 INTENDED USE ......4 9.3.2.1 Flowrate units of measurement ..16 3 CONTENT OF THE PACKAGE ..4 9.3.2.2 Volume units of measurement ..
  • Page 4: Introduction

    INTRODUCTION PRODUCT DESCRIPTION VISIO is a very compact and accurate top-notch multifunction display, able to display any kind of information concerning agricultural treatments. Operator can select the required function via software. It can display several types of values, which change according to set operating mode and type of connected sensors.
  • Page 5: Risks And Protections Before Assembly

    RISKS AND PROTECTIONS BEFORE ASSEMBLY All installation works must be done with battery disconnected, using suitable tools and any individual protection equipment deemed necessary. POSITIONING 1) Set mounting rail in cabin and fasten it with the relevant screws, in a position where VISIO can be easily seen and at hands' reach, but away from any moving organs.
  • Page 6: Assembly Diagrams

    ASSEMBLY DIAGRAMS Counting abort Connection +12VDC (yellow wire) sensor 1 +12Vdc Counting abort Ground sensor 2 connection (green wire) Legend: 1) Power cable 2) Connection cable for double sensors 3) Flowmeter 4) Flowmeter II...
  • Page 7: Controls In The Menu

    CONTROLS IN THE MENU FIRST SWITCHING ON At first switching on, VISIO will run a guided procedure allowing user to set the device's basic settings. Press to scroll through items, to save and move on to next setting, or to go back to previous setting. WARNING: Before changing operating mode, make sure that all sensors / flowmeters are DISCONNECTED from the device.
  • Page 8: Controls In The Menu

    CONTROLS IN THE MENU In the following pages, according to the set operating mode, some menu items could slightly differ from the shown ones. SWITCHING ON A Press for 1 second; B Press the key a few times to view the various values in extended mode (on display central part).
  • Page 9 EDITING A VALUE A Press to move through digits; B Press a few times to edit the highlighted digit; Flowmeter C Press to confirm. The display goes back 00300 pls/l to previous page; Min Value D Press to exit page without confirming Max Value 10000 modification.
  • Page 10: Menu Structure

    MENU STRUCTURE Alarms Min flowrate Max flowrate Min flowrate (II) Max flowrate (II) Sensors Flowmeter Man. calibration Auto calibration Flowmeter (II) Man. calibration Auto calibration Options Language Units of measurem. Flowrate l/min Volume Display contrast Alarm tones Keytones Display settings Data 1 (page 1) Data 2 (page 1) Data 3 (page 1)
  • Page 11: Preliminary Setup For Use

    PRELIMINARY SETUP FOR USE ALARMS Set the values above which you want the display to show an alarm message. 9.1.1 Flowrate alarms Set the minimum and maximum flow meter and flow meter (II) values above which you want the display to show an alarm message. Setup menu >...
  • Page 12: Sensors

    SENSORS Setup menu > Setup menu 1) Open Sensors menu ( Alarms Sensors Sensors Options The menu items displayed below change according to the set operation mode: when more items are available, select the desired one and press to edit it.
  • Page 13: Flowmeter Calibration

    9.2.1 Flowmeter calibration Due to the different system configurations (tubes, valves, etc.) rate reading could not be correct. It is therefore recommended to perform a spraying test. If measured value is different from actual value, change the rate constant through an automatic calibration procedure or manually calculate the constant.
  • Page 14: Automatic Calibration

    9.2.1.2 Automatic calibration Pass through the system a previously measured quantity of liquid or one that can be measured with another previously calibrated system. The higher the quantity of fluid used to perform the calibration procedure, the more accurate the calibration. Setup 1) Open automatic calibration menu ( menu >...
  • Page 15: Options

    OPTIONS 9.3.1 Language Set the desired language. Setup menu Open language setting menu ( > Options > Language Options Language The display will show the current setting English Units of measurem. below the selected item. Display contrast Press to edit language. Language 1) Select a language through English...
  • Page 16: Units Of Measurement

    9.3.2 Units of measurement Set unit of measurement for the values detected by the device. 9.3.2.1 Flowrate units of measurement Open instant rate unit of measurement Setup menu > Options > Units setting menu ( of measurem. > Flowrate Units of measurem. Flowrate Under the selected item, the display l/min...
  • Page 17: Display Contrast

    9.3.3 Display contrast Set display contrast. Setup menu > Open display contrast menu ( Options > Display contrast Options Language Under the selected item, the display Units of measurem. shows the currently set value. Display contrast 50 % Press to edit the selected menu item. 1) Set a value through .
  • Page 18: Alarm Tones

    9.3.4 Alarm tones Enable/disable the alarm tones. Setup menu > Open alarm tones menu ( Options > Alarm tones Options Units of measurem. Under the selected item, the display Display contrast Alarm tones shows the currently set status. Press to edit the selected menu item. 1) Set status through Alarm tones 2) Press...
  • Page 19: Display Settings

    9.3.6 Display settings The main page shows the display divided into three horizontal parts. Setup menu Open Display settings menu ( Options > Options > Display settings Alarm tones Keytones Display settings Press to edit the selected menu item. 1) Select value through key.
  • Page 20: Auto Return P1

    9.3.6.1 Auto return P1 Auto return P1 If several pages are configured (par. 9.3.6), it is possible to set the item " ". This function allows the Visio to automatically return to the main page after the set time (between a minimum of 1 sec. and a maximum of 15 sec.). The default setting is Display settings Data 11 (page 4) Press...
  • Page 21: Operating Mode

    9.3.7 Operating mode Set required operating mode. Setup menu > Open operating mode menu ( Options > Operating mode Options The display will show the current setting Keytones Display settings below the selected item. Operating mode Vol.counters(II) Press pto change the operating mode.
  • Page 22: Setup Management

    SETUP MANAGEMENT VISIO settings can be loaded from or saved on a USB pen drive in order to reconfigure it if required, fix problems or set another VISIO with no need to repeat all manual operations. Once installation is completed, and VISIO operation has been checked, we recommend to save all settings onto a USB pen drive.
  • Page 23 Load setup Allows to select a configuration file saved in the USB pen drive and to set VISIO again. WARNING: By loading the SETUP.BIN file contained in the USB pen drive onto Setup management the VISIO, all current settings will be Save setup lost.
  • Page 24: Test

    TEST This menu allows user to view some data and carry out an operation test of VISIO: - Firmware version: the display shows the firmware version installed. - Hardware version: the display shows the hardware version installed. - Battery voltage: the display shows the power voltage of the device.
  • Page 25: Sensors Test

    9.5.3 Sensors test Sensors test checks correct operation of the sensors connected to the device. Setup menu > Open sensors test menu ( Test Test > Sensors Display Keys Sensors Press to perform the test. The display will show the current sensor reading below the selected item.
  • Page 26: Use

    10 USE The main page shows the display divided into three horizontal parts. Start liquid flow in the system. The display will start showing the increasing value of the measured fluid quantity and instant flowrate. 6.23 6.23 Press key several times to view a 21.84 l/min value in extended mode until value is on...
  • Page 27: Partial Totalizer Reset

    10.1 PARTIAL TOTALIZER RESET To reset a totalizer you must view it in 3000.0 extended mode. 254.0 Press key several times until value to be reset is at the central area of the display. 12.2 l/min 3000.0 Press key for two seconds. 254.0 Totalizer resets.
  • Page 28: Maintenance / Diagnostics / Repairs

    11 MAINTENANCE / DIAGNOSTICS / REPAIRS • Clean only with a soft wet cloth. • Do not use aggressive detergents or products. • Do not clean equipment with direct water jets. 11.1 TROUBLESHOOTING FAULT CAUSE REMEDY Check power cable No power supply connections VISIO is off or does not switch on...
  • Page 29: Technical Data

    12 TECHNICAL DATA 12.1 SETUP MENU Data Min. Max. Default UoM Notes Flowmeter Calibration 10000 pls/l Alarm can be disabled by setting Min flowrate 1000 l/min. value to "OFF" Alarms Alarm can be disabled by setting Max flowrate 1000 l/min. value to "OFF"...
  • Page 30: Device Technical Data

    12.3 DEVICE TECHNICAL DATA Description VISIO Display LCD grafico 128 x 64 pixel retroilluminato Power supply voltage 9 ÷ 16 Vdc Protection against short-circuit • Protection against polarity inversion • Max. frequency 1,2 KHz Analog inputs 4 ÷ 20 mA Digital output - Max current 100 mA Maximum power input (with no...
  • Page 31: Guarantee Terms

    14 GUARANTEE TERMS ARAG s.r.l. guarantees this apparatus for a period of 360 days (1 year) from the date of sale to the client user (date of the goods delivery note). The components of the apparatus, that in the unappealable opinion of ARAG are faulty due to an original defect in the material or production process, will be repaired or replaced free of charge at the nearest Assistance Center operating at the moment the request for intervention is made.
  • Page 32 CONFORMITY DECLARATION The declaration of conformity is available at www.aragnet.com, in the relevant section.
  • Page 33 Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained in time. Always refer to the internet address www.aragnet.com 42048 RUBIERA (Reggio Emilia) - ITALY Via Palladio, 5/A Tel. +39 0522 622011 Fax +39 0522 628944 www.aragnet.com info@aragnet.com...