Operating, servicing, and maintaining this equipment can expose you to chemicals including engine exhaust, carbon monoxide, phthalates, and lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm. To minimize exposure, avoid breathing exhaust, and wear gloves or wash your hands frequently when servicing this equipment. For more information go to www.P65warnings.ca.gov.
Read this manual before using or performing maintenance on this product. Failure to follow the instructions and safety precautions in this manual can result in serious injury or death.
Specifications | |
Model: | iGen4500c |
Running Watts: | 3700 Gas |
Peak Watts: | 4500 Gas |
Rated Voltage: | 120V |
Rated frequency: | 60 Hz |
Phase: | Single phase |
Total Harmonic Distortion: | ≤ 3% |
Engine Displacement: | 224 cc |
Starting Type: | Recoil, Electric Start, Remote |
Fuel Capacity: | 3.4 Gal (12.8 L) |
Fuel Type: | 87–93 octane* |
Oil Capacity: | 0.63 US qt (0.60 L) |
Oil Type: | 10W30 |
Spark Plug: | F7RTC |
Spark Plug Gap: | 0.024 – 0.032 in. (0.60 – 0.80 mm) |
Valve Intake Clearance: | 0.0031 – 0.0047 in (0.08 – 0.12 mm) |
Valve Exhaust Clearance: | 0.0051 – 0.0067 in (0.13 – 0.17 mm) |
AC Grounding System: | Floating neutral |
Voltage Regulator: | Digital |
Alternator Type: | Permanent magnet |
Maximum Ambient Temperature: | 104°F (40°C) |
Certifications: |
|
*Ethanol content of 10% or less. DO NOT use E15 or E85.
NOTICE
This product is designed and rated for continuous operation at ambient temperatures up to 104°F (40°C). If needed, this product can be operated at temperatures ranging from 5°F (15°C)–122°F (50°C) for short periods. If the product is exposed to temperatures outside of this range during storage, it should be brought back within this range before operation. This product must always be operated outdoors in a well-ventilated area and away from doors, windows, and other vents.
Maximum wattage and current are subject to and limited by such factors as fuel BTU content, ambient temperature, altitude, engine conditions, etc. Maximum power decreases about 3.5% for each 1,000 feet above sea level, and will also decrease about 1% for each 10°F (6°C) above 60°F (16°C) ambient temperature.
For trouble-free warranty coverage, it is important to register your Westinghouse generator.
You can register by:
Keep your purchase receipt for trouble-free warranty coverage.
The words DANGER, WARNING, CAUTION and NOTICE are used throughout this manual to highlight important information. Make sure that the meanings of this safety information is known to all who operate, perform maintenance on, or are near the generator.
This safety alert symbol appears with most safety statements. It means attention, become alert, your safety is involved! Please read and abide by the message that follows the safety alerts symbol.
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
Indicates a situation which can cause damage to the generator, personal property, and/or the environment, or cause the equipment to operate improperly.
Note:
Indicates a procedure, practice or condition that should be followed for the generator to function in the manner intended.
Follow all safety information contained in this manual and on the generator.
Symbol | Description |
| Safety Alert Symbol |
![]() | Electrocution Hazard |
![]() | Asphyxiation Hazard |
| Burn Hazard. Do not touch hot surfaces. |
| Electrical Shock Hazard |
![]() | Fire Hazard |
![]() | Maintain Safe Distance |
![]() | Lifting Hazard |
![]() | Read Manufacturer's Instructions |
![]() | Do Not Operate in Wet Conditions |
CORRECT USAGE
Example location to reduce risk of carbon monoxide poisoning
INCORRECT USAGE
Do not operate in any of the following locations:
NOTICE
Install battery-powered carbon monoxide detectors or plug-in carbon monoxide detectors with battery back-up in living areas.
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or garage, EVEN IF doors and windows are open.
Only use OUTSIDE and far away from windows, doors, and vents.
Fire and electrocution hazard. Do not connect to a building's electrical system unless the generator and transfer switch have been properly installed and the electrical output has been verified by a qualified electrician. The connection must isolate the generator power from utility power and must comply with all applicable laws and electrical codes.
Electrocution hazard. Never use the generator in a location that is wet or damp. Never expose the generator to rain, snow, water spray, or standing water while in use. Protect the generator from all hazardous weather conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit.
Fire and explosion hazard. Gasoline and LPG/propane are highly explosive and flammable and can cause severe burns or death.
The CO Sensor monitors for the accumulation of poisonous carbon monoxide gas around the generator when the engine is running. If increasing levels of CO gas are detected, the CO Sensor automatically shuts down the engine.
The CO Sensor will also detect the accumulation of carbon monoxide from other fuel burning sources used in the area of operation. For example, if the exhaust of fuel burning tools is pointed at a CO Sensor-equipped generator, a shut-off may be initiated due to rising CO levels. This is not an error. Hazardous carbon monoxide has been detected. Move and redirect any additional fuel burning sources to dissipate carbon monoxide away from personnel and occupied buildings.
Note: Remote start-equipped generators must be restarted with the START/STOP button on the control panel after an automatic shut-down occurs.
Generators are intended to be used outdoors, far from occupied buildings and the exhaust pointed away from personnel and buildings. If misused and operated in a location that results in the accumulation of CO, like in a partially enclosed area, the CO Sensor shuts off the engine, notifies the user with a RED indicator light, and directs the user to read the Action Label for steps to take. The CO Sensor DOES NOT replace carbon monoxide alarms. Install battery-powered carbon monoxide alarm(s) in your home.
Automatic shutoff accompanied with a flashing RED light in the CO Sensor portion of the control panel is an indication that the generator was improperly located. If you start to feel sick, dizzy, weak, or carbon monoxide detectors in your home indicate an alarm, get to fresh air immediately. Call emergency services. You may have carbon monoxide poisoning.
CO SENSOR INDICATOR LIGHTS
Color | Description |
RED | Carbon monoxide accumulated around the generator. After shut-off, the RED indicator light in the CO Sensor area of the control panel will flash to provide notification that the generator was shut-off due to an accumulating CO hazard. The RED light will flash for at least five minutes after a CO shut-off. Move the generator to an open, outdoor area far away from occupied spaces with exhaust pointed away. Once relocated to a safe area, the generator can be restarted. Introduce fresh air and ventilate the area where the generator had shut down. |
YELLOW | A CO sensor system fault occurred. When a system fault occurs, the generator is automatically shut down and the YELLOW indicator light in the CO auto-shutoff area of the control panel will flash to provide notification that the a fault has occurred. The YELLOW light will flash for at least five minutes after a fault. The generator can be re-started, but may continue to shutoff. A CO sensor fault can only be diagnosed and repaired by an authorized Westinghouse service center. |
ACTION LABEL
SAFETY LABELS AND DECALS
DATA CENTER
Push the Mode button to cycle through the data display modes.
Voltage:
Displays current voltage output.
Frequency (Hz):
Displays power output frequency in Hertz.
Lifetime Hours:
Displays the lifetime run hours.
Run Time/Maintenance:
Displays current run time. Resets to zero when shut down. Maintenance reminder displayed when required.
Weight hazard. Always have assistance when lifting the generator.
CARTON CONTENTS
If any parts are missing, contact our service team at service@wpowereq.com or call 1-855-944-3571.
NOTICE
THIS GENERATOR HAS BEEN SHIPPED WITHOUT OIL. Do not attempt to crank or start engine before it has been properly serviced with recommended oil. Failure to add engine oil before starting will result in serious engine damage.
NOTICE
Use of 2-stroke/cycle oil or other unapproved oil types can cause severe engine damage that is not covered under warranty.
The included, recommended oil type for typical use is 10W-30 engine oil. If running the generator in extreme temperatures, refer to the following chart.
Fire and explosion hazard. Never use a gasoline container, gasoline tank, propane connector hose, propane tanks, or any other fuel item that is broken, cut, torn or damaged.
Fire and explosion hazard. Do not overfill fuel tank. Fill only to the red fill ring located in the in-tank fuel screen filter. Overfilling may cause fuel to spill onto engine causing a fire or explosion hazard.
Fire and explosion hazard. Never refuel the generator while the engine is running. Always turn the engine off and allow the generator to cool for two minutes before refueling.
NOTICE
Do not use E15 or E85 fuel in this product. Engine or equipment damage caused by stale fuel or E85 E15 the use of unapproved fuels (such as E15 or E85 ethanol blends) is not covered by warranty. Only use unleaded gasoline containing up to 10% ethanol.
Adding a fuel stabilizer (not included) extends the usable life of fuel and helps prevent deposits from forming that can clog the fuel system. Follow the manufacturer's instructions for use.
Always mix the correct amount of fuel stabilizer to gasoline in an approved gasoline container before fueling the generator. Run the generator for five minutes to allow the stabilizer to treat the entire fuel system.
Align the tabs on the bottom of the battery access cover with the generator case then push to reinstall the cover.
Note: The generator is equipped with a battery charging feature. Once the engine is running, a small charge will slowly recharge the battery.
Read and understand all safety information before starting the generator.
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or garage, EVEN IF doors and windows are open.
Only use OUTSIDE and far away from windows, doors, and vents.
NEVER operate the generator inside any building, including garages, basements, crawlspaces, sheds, enclosure, or compartment, including the generator compartment of a recreational vehicle.
Electrocution hazard. Never use the generator in a location that is wet or damp. Never expose the generator to rain, snow, water spray, or standing water while in use. Protect the generator from all hazardous weather conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit. Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet, could result in electrocution
Fire hazard. Only operate the generator on a solid, level surface. Operating the generator on a surface with loose material such as sand or grass clippings can cause debris to be ingested by the generator that could block cooling vents or the air intake system. Allow the generator to cool for 30 minutes before transport or storage.
The generator should be on a flat, level surface at all times (Even while not in operation). The generator must have at least 5 ft. (1.5 m) of clearance from all combustible material.
Do not operate the generator in the back of a SUV, camper, trailer, truck bed (regular, flat, or otherwise), under stairs, next to walls or buildings, or in any other location that will not allow for adequate cooling of the generator and/or the muffler. DO NOT contain generators during operation.
Asphyxiation hazard. Place the generator in a well ventilated area. DO NOT place the generator near vents or intakes where exhaust fumes could be drawn into occupied or confined spaces. Carefully consider wind and air currents when positioning generator.
Shock hazard. Failure to properly ground the generator can result in electric shock.
The generator neutral is floating. The generator ground terminal is connected to the frame of the generator, the metal non-current-carrying parts of the generator, and the ground terminals of each receptacle. The generator (stator winding) is isolated from the frame and from the AC receptacle ground pin. Electrical devices that require a grounded receptacle pin connection may not function properly.
If this generator will be used only with cord and plug equipment connected to the receptacles mounted on the generator, National Electric Code does not require that the unit be grounded. However, other methods of using the generator may require grounding to reduce the risk of shock or electrocution.
Before using the ground terminal, consult a qualified electrician, electrical inspector, or local agency having jurisdiction for local codes or ordinances that apply to the intended use of the generator.
NOTICE
Only use grounded 3-prong extension cords, tools, and appliances, or double-insulated tools and appliances.
Engine power is reduced the higher you operate above sea level. Output will be reduced approximately 3.5% for every 1000 feet of increased altitude from sea level.
High altitude adjustment is required for operation at altitudes over 5,000 ft. (1524 m). Operation without this adjustment will cause decreased performance, increased fuel consumption, and increased emissions. Operation of the engine at altitudes below 2,000 ft. (762 m) with the high altitude kit is not recommended.
High Altitude Carburetor Kit: | Part# 518916-01 |
High Altitude DF Regulator | |
Manufactured before 7/19: | Part# 518918 |
Manufactured 7/19 and later: | Part# 518918-01 |
Note: You must purchase both the Dual Fuel Regulator and Carburetor Kit for proper high altitude operation.
Verify that the area around the generator is clear before remote starting the generator.
The remote start key fob included with the generator should be attached to the recoil handle or control panel. If your unit was shipped without a key fob, contact Westinghouse customer service.
The generator can be started remotely from up to 99 feet (30 meter) using the remote start key fob.
Note: As the batteries in the remote start key fob drain, operational distance will decrease.
Remote replacement batteries: (2) CR2016
If the remote start key fob is replaced or needs re-paired to the generator, follow this procedure.
Turn the fuel switch fully to the right for gasoline operation.
Turn the fuel switch fully to the left to shut the fuel valve OFF.
For proper break-in, do not exceed 50% of the rated running watts (1850 watts) during the first five hours of operation.
Vary the load occasionally to allow stator windings to heat and cool and help seat the piston rings.
Verify that:
Fire and explosion hazard. DO NOT move or tip the generator during operation.
Note: The engine will automatically set the choke and begin the start sequence. If the engine fails to start, the generator will attempt to start the engine two more times.
If the generator will be used on an infrequent or intermittent basis (more than one month before next use), refer to the Battery Maintenance and Storage sections of this manual for information regarding battery charging and fuel deterioration.
NOTICE
Always start the generator with ECO MODE OFF. Allow the engine speed to stabilize and the OUTPUT READY LED to illuminate before switching ECO MODE ON.
Note: Do not use ECO MODE when in parallel operation with another Westinghouse generator.
ECO MODE minimizes fuel consumption and noise by adjusting the engine RPM to the minimum required for the current load.
Turn ECO MODE ON when powering small appliances with continuous loads such as a computer or electric light.
Turn ECO MODE OFF when powering large surge loads such as an air conditioner or electric pump.
To turn on ECO MODE, verify that the OUTPUT READY LED is illuminated green, then push the switch to the ON position. If no load is present, the generator RPM will drop to idle speed. The generator will detect loads as they are applied and increase engine RPM.
To run the generator at maximum power and RPM, push the ECO MODE switch to the OFF position.
The circuit breakers will automatically switch OFF if there is a short circuit or a significant overload of the generator at each receptacle. The main circuit breaker will automatically switch OFF if the combined load of the receptacles exceeds 31 Amps.
If an AC circuit breaker switches OFF automatically, check that the appliance is working correctly and it does not exceed the rated load capacity of the circuit before resetting the AC circuit breaker ON.
The generator will automatically switch OFF all AC output to protect the generator if overloaded or if there is a short circuit in a connected appliance. However, the engine will continue to run. Marginal overloading that temporarily illuminates the OVERLOAD LED may shorten the service life of the generator.
OVERLOAD on the control panel will illuminate red and the green OUTPUT READY will be OFF.
To restore AC output:
NOTICE
Do not overload the generator's capacity. Exceeding the generator's wattage/amperage capacity can damage the generator and/or electrical devices connected to it.
Make sure the generator can supply enough continuous (running) and surge (starting) watts for the items you will power at the same time.
The total power requirements (Volts x Amps = Watts) of all appliances connected must be considered. Appliance and power tool manufacturers usually list rating information near the model or serial number.
To determine power requirements:
Example:
*Wattages listed are approximate. Verify actual wattage.
To prolong the life of the generator and attached devices, use care when adding electrical loads to the generator. There should be nothing connected to the generator outlets before starting the engine. The correct and safe way to manage generator power is to sequentially add loads as follows:
Wattage Reference
Tool or Appliance | Estimated Running Watts* | Estimated Starting Watts* |
Incandescent Lights (4 Quantity x 75 Watts) | 300 | 0 |
TV (Tube Type) | 300 | 0 |
Sump Pump (1/3 hp) | 800 | 1300 |
Refrigerator or Freezer | 700 | 2200 |
Well Pump (1/3 hp) | 1000 | 2000 |
Furnace (1/2 hp) | 800 | 2350 |
Radio | 200 | 0 |
Drill (3/8", 4 amps) | 440 | 600 |
Circular Saw (Heavy Duty, 7-1/4") | 1400 | 2300 |
Miter Saw (10") | 1800 | 1800 |
Table Saw (10") | 2000 | 2000 |
*Wattages listed are approximate. Verify actual wattage.
Asphyxiation hazard. Extension cords running directly into the home increase the risk of carbon monoxide poisoning through any openings. If an extension cord running directly into your home is used to power indoor items, there is a risk of carbon monoxide poisoning to people inside the home. Always use battery-powered carbon monoxide detector (s) that meet current UL 2034 safety standards when running the generator. Regularly check the detector (s) battery.
Asphyxiation hazard. When operating the generator with extension cords, make sure the generator is located in an open, outdoor area, far away from occupied spaces with exhaust pointed away.
Fire and electrocution hazard. Never use worn or damaged extension cords. Damaged or overloaded extension cords could overheat, arc, and burn resulting in death or serious injury.
Before connecting an AC appliance or power cord to the generator:
Only use grounded 3-prong extension cords marked for outdoor use that are rated for the electrical load.
![]() | ||
Total | Minimum Gauge, Outdoor Rated | |
Amperage | Up to 50 FT (15 M) | Up to 100 FT (30 M) |
Up to 10A | ![]() | ![]() |
Up to 15A | ![]() | ![]() |
Up to 20A | ![]() | ![]() |
Up to 30A | ![]() | ![]() |
Up to 35A | ![]() | ![]() |
Fire and electrocution hazard. Never connect or disconnect the parallel cord leads when a generator is running.
NOTICE
Connecting the iGen4500c to a generator that is not compatible can cause a low voltage output that can damage tools and appliances powered by the generator.
Parallel operation allows you to link the iGen4500c to a compatible Westinghouse Inverter Generator for combined running and peak power output. A Westinghouse parallel cord (purchased separately) is required for parallel operation. This cord can be purchased from an authorized Westinghouse Generator dealer.
Note: Do not use ECO MODE when in parallel operation with another Westinghouse generator.
Parallel cord (50A/6000 Watts): Part# 507PC
Note: Compatible Westinghouse generators without parallel ports can be operated in parallel with the receptacle-mounted parallel cable, Part# 260041.
Weight hazard. Always have assistance when lifting the generator.
Fire hazard. Do not up-end the generator or place it on its side. Fuel or oil can leak and damage to the generator may occur.
Regular maintenance will improve performance and extend the service life of the generator. Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions as noted below.
Before Each Use
Check engine oil
After First 25 Hours or First Month
Change engine oil
After 50 Hours or Every 6 Months
Change engine oil1
Clean air filter2
After 100 Hours or Every 6 Months
Inspect/clean spark arrestor
Inspect/clean spark plug
Replace fuel filter3
Inspect/adjust valve clearance3
After 300 Hours or Every Year
Replace spark plug
Replace air filter
Description | Part Number |
Foam air filter | 5691 |
Oil drain plug crush washer | 94007 |
Spark arrestor | 6790 |
Battery | 511019 |
Spark plug | F7RTC |
Remove the engine service cover to access the air filter, carburetor, and spark plug. Remove the cover screws then pull the cover straight out with both hands to prevent damage to the grommet posts on the cover.
Fire hazard. Never use gasoline or other flammable solvents to clean the air filter. Use only household detergent soap to clean the air filter.
The air filter must be cleaned after every 50 hours of use or six months (frequency should be increased if the generator is operated in a dusty environment).
Air Filter: Part# 5691
Avoid skin contact with engine oil. Wear protective clothing and equipment. Wash all exposed skin with soap and water.
NOTICE
Always use the specified engine oil. Failure to use the specified engine oil can cause accelerated wear and/or shorten the life of the engine.
When using the generator under extreme, dirty, dusty conditions or in extremely hot weather, change the oil more frequently.
Ambient air temperature will affect engine oil performance. Change the type of engine oil used based on weather conditions.
Check the engine oil level before each use or every 8 hours of operation.
Accidental start-up. Remove the spark plug boot from the spark plug when working on the generator. Also remove the battery quick-connect plug from the battery.
When using the generator under extreme, dirty, dusty conditions or in extremely hot weather, change the oil more frequently. Change the oil while the engine is still warm from operation.
NOTICE
Do not pollute. Follow the guidelines of the EPA or other governmental agencies for proper disposal of hazardous materials. Consult local authorities or reclamation facility.
Inspect and clean the spark plug after every 100 hours of use or six months. Replace the spark plug after 300 hours of use or every year.
Westinghouse Model Number | Torch | NGK | Bosch | Autolite |
iGen4500DF | F7RTC | BPR7ES | WR5D | 62 |
Check and clean the spark arrestor after every 100 hours of use or six months. Failure to clean the spark arrestor will result in degraded engine performance.
The battery shipped with the generator has been fully charged. A battery may lose some charge when not in use for prolonged periods of time. If the battery is unable to crank the engine, plug the included 12V charger into the battery charging port on the control panel.
Note: If the generator is not run, charge the battery overnight once a month.
The supplied battery charger is not a trickle charger and is not intended for continuous use. Do not use the battery charger for more than 8 hours (overnight) to prevent overcharging the battery.
Note: Once started, the generator will charge the battery after 30–60 minutes of use. If you do not regularly run the generator, charge the battery overnight once a month to keep it ready for use. Charge the battery in a dry location.
Battery, 12V/6.5 Ah: Part# 511019
Burn hazard. The battery contains sulfuric acid (electrolyte) which is highly corrosive and poisonous. Wear protective clothing and eye protection when working near the battery. Keep children away from the battery.
Battery posts, terminals contain lead and lead compounds. Wash hands after handling.
NOTICE
Dispose of the used battery properly according to the guidelines established by your local or state government.
Proper storage preparation is required for trouble-free operation and generator longevity.
NOTICE
Gasoline stored for as little as 30 days can deteriorate, causing gum, varnish, and corrosive buildup in fuel lines, fuel passages and the engine. This corrosive buildup restricts the flow of fuel, which can prevent the engine from starting after a prolonged storage period. The use of fuel stabilizer significantly increases the storage life of gasoline. Full-time use of fuel stabilizer is recommended. Follow the manufacturer's instructions for use.
STORAGE TIME | RECOMMENDED PROCEDURE |
Less than 1 month | No service required. |
2 to 6 months | Fill with fresh gasoline and add gasoline stabilizer. Drain the carburetor float bowl. |
6 months or longer | Drain the fuel tank and carburetor float bowl. |
Even properly stabilized fuel can leave residue and cause corrosion if left long term. If storing the generator for two to six months, drain the float bowl to prevent gum and varnish buildup in the carburetor.
DRAINING THE FLOAT BOWL
DRAINING THE FUEL TANK
If storing the generator for longer than six months, drain the fuel tank to prevent fuel separation, deterioration, and deposits in the fuel system.
NOTICE
Checking and adjusting valve clearance must be done when the engine is cold.
Intake Valve | Exhaust Valve | |
Valve Clearance | 0.0031 – 0.0047 in (0.08 – 0.12 mm) | 0.0051 – 0.0067 in (0.13 – 0.17 mm) |
Torque | 8-12 N•m | 8-12 N•m |
If the battery is dead or disconnected, you may need to set the choke by hand for proper operation.
POSSIBLE CAUSE | CORRECTION | |
Engine will not start | Battery switch in the OFF position. | Turn battery switch to the ON position. |
Out of fuel. | Refuel. | |
Bad fuel, generator stored without treating or draining gasoline, or refueled with bad gasoline. | Drain the fuel tank. Refuel with fresh gasoline. | |
Dirty air filter. | Clean the air filter. | |
Low engine oil level stopped generator. | If low oil LED illuminated, turn battery switch to the OFF position. Add engine oil. | |
Spark plug wet with fuel (flooded engine). | Wait five minutes. Turn battery switch to the OFF position. Pull recoil handle rapidly several times. If the generator does not start, remove spark plug and dry. | |
Spark plug faulty, fouled, or improperly gapped. | Gap or replace the spark plug. Reinstall. | |
Fuel filter restricted, fuel system malfunction, fuel pump failure, ignition malfunction, valves stuck, etc. | Contact Westinghouse customer service tollfree at 1 (855) 944-3571. | |
Battery drained. | Use the recoil handle to start the generator. | |
Charge the battery. | ||
Choke partially open or closed due to weak or disconnected battery. | Manually set the choke. See Maintenance section. | |
CO sensor removed or modified | Return to original configuration | |
CO sensor activated or system fault occurred | Relocate generator/ Contact Westinghouse customer service toll free at 1 (855) 944-3571. | |
Engine starts, then shuts down | Out of fuel. | Refuel. |
Incorrect engine oil level. | Check engine oil level. | |
Dirty air filter. | Clean the air filter. | |
Contaminated fuel. | Drain the fuel tank. Refuel with fresh gasoline. | |
Defective low oil level switch. | Contact Westinghouse customer service tollfree at 1 (855) 944-3571. | |
Engine lacks power | Air filter restricted. | Clean or replace air filter. |
Bad fuel, generator stored without treating or draining gasoline, or refueled with bad gasoline. | Drain the fuel tank. Refuel with fresh gasoline. | |
Fuel filter restricted, fuel system malfunction, fuel pump failure, ignition malfunction, valves stuck, etc. | Contact Westinghouse customer service tollfree at 1 (855) 944-3571. | |
Engine runs rough or bogs when load applied | Dirty air filter. | Clean the air filter. |
Generator overloaded. | Unplug some devices. | |
Faulty power tool or appliance. | Replace or repair tool or appliance. Stop and restart the engine. | |
Fuel filter restricted, fuel system malfunction, fuel pump failure, ignition malfunction, valves stuck, etc. | Contact Westinghouse customer service tollfree at 1 (855) 944-3571. | |
No power at AC receptacles | AC circuit breaker/s tripped. | Check AC loads and reset circuit breaker/s. |
Faulty power tool or appliance. | Replace or repair tool or appliance. Stop and restart the engine. | |
Faulty generator. | Contact Westinghouse customer service tollfree at 1 (855) 944-3571. |
EXPLODED VIEW A
NO. | Code | Description |
1 | CYLINDER HEAD COVER ASSEMBLY | |
1.1 | 91325 | BOLT M6 |
1.2 | 241115 | CYLINDER HEAD COVER |
1.3 | 339915 | POLYURETHANE SCREEN |
1.4 | 241116 | CYLINDER HEAD INTERNAL COVER |
1.5 | 91322 | BOLT M5 |
1.6 | 96200 | CYLINDER HEAD COVER GASKET |
2 | CYLINDER HEAD ASSEMBLY | |
2.1 | 242101 | ROCKING ARM |
2.2 | 91818 | ROCKING ARM WITH TIGHT BOLT |
2.3 | 242202 | VALVE RETAINER ASSEMBLY |
2.4 | 241804 | TOP CAP |
2.5 | 241801 | INTAKE VALVE SPRING SEAT |
2.6 | 241802 | EXHAUST VALVE SPRING SEAT |
2.7 | 246001 | VALVE SPRING |
2.8 | 241806 | INTAKE VALVE SPRING LOWER SEAT |
2.9 | 241704 | INTAKE VALVE |
2.10 | 245904 | EXHAUST VALVE |
2.11 | 91029 | AIR INLET STUD BOLT |
2.12 | 91359 | BOLT M8 |
2.13 | 241021 | CYLINDER HEAD |
2.14 | 96058 | CYLINDER HEAD GASKET |
2.15 | 240905 | CYLINDER HEAD LOCATING PIN |
2.16 | 91007 | AIR EXHAUST STUD BOLT |
2.17 | 96055 | EXHAUST GASKET |
2.18 | 96182 | INTAKE GASKET |
2.19 | 96051 | CARBURETOR GASKET |
3 | PISTON & PISTON RING ASSEMBLY | |
3.1 | 241607 | PISTON RING |
3.2 | 241301 | PISTON PIN RING |
3.3 | 241211 | PISTON |
3.4 | 245503 | PISTON PIN |
3.5 | 331500 | CONNECTING ROD |
4 | CRANKCASE ASSEMBLY | |
4.1 | 330202 | CRANKCASE |
4.2 | 93010 | BEARING |
4.3 | 93507 | CRANKCASE OIL SEAL |
4.4 | 97447 | STARTING MOTOR ASSEMBLY |
4.5 | 91333 | BOLT M6 |
4.6 | 91334 | BOLT M6 |
4.7 | 245113 | OIL SENSOR |
4.8 | 91329 | BOLT M6 |
4.9 | 91816 | OIL DRAIN BOLT |
4.10 | 94007 | OIL DRAIN BOLT WASHER |
4.11 | 94035 | OIL DRAIN BOLT WASHER |
4.12 | 91831 | OIL DRAIN SOLENOID |
5 | CRANKSHAFT ASSEMBLY | |
6 | 50150005 | CAMSHAFT ASSEMBLY |
6.1 | 332003 | CAMSHAFT |
6.2 | 246103 | VALVE LIFTER |
6.3 | 241901 | PUSH ROD |
7 | CRANKCASE COVER ASSEMBLY | |
7.1 | 240116 | CRANKCASE |
7.2 | 245601-295 | DIPSTICK |
7.3 | 93507 | CRANKCASE OIL SEAL |
7.4 | 91347 | BOLT M8 |
7.5 | 96041 | CRANKCASE GASKET |
7.6 | 240904 | CRANKCASE LOCATING PIN |
7.7 | 93010 | BEARING |
8 | 599601 | METAL CLIP |
9 | RECOIL STARTER ASSEMBLY | |
9.1 | 330501 | RECOIL STARTER |
9.1.1 | 5324 | RECOIL COVER |
9.2 | 91329 | BOLT M6 |
9.3 | 500017-231 | RECOIL HANDLE COVER |
9.4 | 500018 | RECOIL HANDLE |
10 | IMPELLER ASSEMBLY | |
10.1 | 91864 | STARTER PULLEY COMPRESSION BOLT |
10.2 | 334501 | STARTER PULLEY |
10.3 | 334601 | IMPELLER |
11 | ROTOR ASSEMBLY | |
11.1 | 90003 | NUT M14 |
11.2 | 500191 | ROTOR |
12 | STATOR ASSEMBLY | |
12.1 | 91400 | BOLT M6 |
12.2 | 503410 | STATOR |
12.3 | 240904 | CRANKCASE LOCATING PIN |
13 | TRIGGER ASSEMBLY | |
13.1 | 91329 | BOLT M6 |
13.2 | 339902 | TRIGGER |
14 | WIND-LEAD-COVER ASSEMBLY | |
14.1 | 330503 | WIND-LEAD-COVER |
14.2 | 91325 | BOLT M6X12 |
15 | UPPER WIND DEFLECTOR ASSEMBLY | |
15.1 | 330502 | UPPER WIND DEFLECTOR |
15.2 | 249914 | CRIMPING BLOCK |
15.3 | 91325 | BOLT M6X12 |
16 | IGNITION COIL ASSEMBLY | |
16.1 | 91333 | BOLT M6 |
16.2 | 339909 | IGNITION COIL |
16.3 | 339903 | HI-VOLTAGE PKG MOUNTING BRACKET |
16.4 | 90016 | NUT M6 |
17 | 335803 | TEMPERATURE SENSOR |
18 | CENTRIFUGAL FAN HOUSING ASSEM- BLY | |
18.1 | 244306 | CENTRIFUGAL FAN HOUSING |
18.2 | 244304 | CENTRIFUGAL FAN PLUG |
18.3 | 91343 | BOLT M8 |
18.4 | 244606 | IMPELLER |
18.5 | 91419 | BOLT M8 |
18.6 | 334302 | CENTRIFUGAL FAN COVER |
18.7 | 91330 | BOLT M6 |
19 | EXHAUST MUFFLER ASSEMBLY | |
19.1 | 243782 | MUFFLER |
19.1.1 | 6790 | SPARK ARRESTER |
19.2 | 94216 | FLAT WASHER |
19.3 | 94206 | SPRING WASHER |
19.4 | 90011 | NUT M8 |
19.5 | 91330 | BOLT M6 |
19.6 | 500057 | MUFFLER COVER |
20 | 240511 | SHIELD |
21 | BRACKET ASSEMBLY | |
21.1 | 91330 | BOLT M6 |
21.2 | 249917 | BRACKET |
22 | AIR FILTER ASSEMBLY | |
22.1 | 332901 | AIR FILTER |
22.1.1 | 5691 | AIR FILTER |
22.2 | 95918 | CONNECTING PIPE |
23 | CARBURETOR ASSEMBLY | |
23.1 | 332301 | CARBURETOR CONNECTION BLOCK |
23.2 | 92219 | SCREW M4 |
23.3 | 90016 | NUT M6 |
23.4 | 94226 | STEEL WASHER |
23.5 | 332801 | CARBURETOR ASSEMBLY |
23.6 | 249925 | STEPPER MOTOR BRACKET |
23.7 | 92055 | CROSS SCREW STUD M4 |
23.8 | 249949 | STEPPER MOTOR |
23.9 | 249950 | STEPPER MOTOR |
23.10 | 92240 | CROSS SCREW STUD M4 |
23.11 | 249934 | WATERPROOF COVER |
24 | RESONANT CAVITY ASSEMBLY | |
24.1 | 337001 | RESONANT CAVITY |
24.1.1 | 5697 | FOAM FILTER |
24.2 | 249919 | PLUG |
24.3 | 95602 | BREATHER TUBE |
24.4 | 94407 | FUEL LINE CLAMP |
25 | 97109 | SPARK PLUG |
EXPLODED VIEW B
NO. | Code | Description |
1 | ENGINE ASSEMBLY DH225 | |
2 | INVERTER ASSEMBLY | |
2.1 | 91325 | BOLT M6 |
2.2 | 503147 | INVERTER MODULE |
2.3 | 503013 | BRACKET |
2.4 | 91322 | BOLT M5 |
2.5 | 599601 | METAL CLIP |
2.6 | 91325 | BOLT M6X12 |
2.7 | 500044 | SHORT WIRE |
2.8 | 94003 | TOOTH WASHER |
2.9 | 503048 | DC VOLTAGE REGULATOR |
3 | LEFT PANEL ASSEMBLY | |
3.1 | 503039-221E | LEFT PANEL |
3.2 | 92097 | SCREW M6 |
3.3 | 92079 | STOP BOLT M6 |
4 | LEFT FRAME ASSEMBLY | |
4.1 | 503005-221 | LEFT FRAME |
4.2 | 91345 | BOLT M8 |
4.3 | 500060 | LOCK CLIP M6 |
4.4 | 92097 | SCREW M6 |
4.5 | 500007 | FUEL TANK ISOLATION PAD A |
5 | BRACKET ASSEMBLY | |
5.1 | 503001 | BRACKET |
5.2 | 503002 | BRACKET |
5.3 | 503003 | BRACKET |
5.4 | 503004 | ISOLATION PAD |
5.5 | 90044 | NUT M8 |
5.6 | 91348 | BOLT M8 |
6 | BRACKET ASSEMBLY | |
6.1 | 91325 | BOLT M6 |
6.2 | 503017 | BRACKET |
6.3 | 503772 | FUEL LINE |
6.4 | 503773 | FUEL LINE |
6.5 | 503020L | FUEL LINE |
6.6 | 503044 | CLIP |
6.7 | 503062 | FUEL SWITCH |
6.8 | 503034 | FUEL LINE CLAMP |
6.9 | 516401 | FILTER |
7 | PANEL REAR COVER ASSEMBLY | |
7.1 | 503016 | PANEL REAR COVER |
7.2 | 92078 | SCREW M6 |
8 | PANEL ASSEMBLY | |
8.1 | 503801 | PANEL |
8.1.1 | 9222 | ROCKER SWITCH |
8.1.2 | 9223 | ONE PUSH BUTTON SWITCH |
8.1.3 | 9224 | ECO SWITCH |
8.1.4 | 9079 | WATERPROOF CAP |
8.1.5 | 9227-31 | THERMAL PROTECTOR |
8.1.6 | 6404 | WATERPROOF CAP |
8.1.7 | 9226 | CHARGING SOCKET |
8.1.8 | 9225 | START INDICATOR |
8.1.9 | 9227-30 | THERMAL PROTECTOR |
8.1.10 | 6404 | WATERPROOF CAP |
8.1.11 | 9227-20 | THERMAL PROTECTOR |
8.1.12 | 6404 | WATERPROOF CAP |
8.1.13 | 9228 | IGNITER |
8.1.14 | 9229 | USB |
8.1.15 | 503108 | USB DUST COVER |
8.1.16 | 9230 | VOLTAGE RESET SWITCH |
8.1.17 | 9235 | LED |
8.1.18 | 9232 | PARALLEL SOCKET |
8.1.19 | 9122 | WATERPROOF COVER |
8.1.20 | 6032 | L5-20R RECEPTACLE |
8.1.21 | 9194 | DUST COVER |
8.1.22 | 9132 | GROUNDING BOLT |
8.1.23 | 6015 | RV SOCKET |
8.1.24 | 6849 | DUST COVER |
8.1.25 | 9236 | CO WARNING LIGHT |
8.1.26 | 9236 | CO WARNING LIGHT |
8.2 | 91825 | SCREW & FLAT WASHER |
8.3 | 503024 | KNOB |
8.4 | 500068 | HANDLE PANEL PLUG |
8.5 | 92032 | SCREW M4 |
8.6 | 94325 | FLAT WASHER |
8.7 | 503310 | KNOB PLUG |
9 | BASEBOARD ASSEMBLY | |
9.1 | 90027 | SQUARE NUT |
9.2 | 91325 | BOLT M6 |
9.3 | 503045 | BOTTOM PLATE |
9.4 | 500060 | LOCK CLIP M6 |
9.5 | 503026 | ISOLATION PAD |
9.6 | 503023 | AXLE |
9.7 | 503031 | WHEEL |
9.8 | 503032 | WHEEL COVER |
9.9 | 94022 | STEEL WASHER |
9.10 | 500321 | AXLE WILD CARD |
9.11 | 503053 | LIMIT BLOCK |
9.12 | 503052 | BASE OIL COVER |
9.13 | 91334 | BOLT M6X30 |
9.14 | 100310003 | PULL ROD ASSEMBLY |
9.14.1 | 503033 | PULL ROD SEAT |
9.14.2 | 503035 | PULL ROD |
9.14.3 | 91334 | BOLT M6X30 |
10 | RIGHT FRAME ASSEMBLY | |
10.1 | 503021-221E | RIGHT FRAME |
10.2 | 91345 | BOLT M8X20 |
10.3 | 500060 | LOCK CLIP M6 |
10.4 | 503067 | BLIND RIVET |
10.5 | 503036-052 | HANDLE DECORATIVE BOARD |
10.6 | 94249 | FLAT WASHER |
10.7 | 92097 | SCREW M6 |
11 | 503022-221 | OBSERVATION COVER |
12 | CO MODULE ASSEMBLY | |
12.1 | 503807 | CO MODULE BRACKET |
12.2 | 599070 | CO MODULE |
12.3 | 599071 | CO FLAMEOUT ACTUATOR |
12.4 | 92328 | BOLT M4 |
12.5 | 91325 | BOLT M6X |
12.6 | 90016 | NUT M6 |
13 | MUFFLER PANEL ASSEMBLY | |
13.1 | 503027 | MUFFLER PANEL |
13.2 | 500108 | MUFFLER EXHAUST SEALING STRIP |
13.3 | 503040 | COVER |
13.4 | 92078 | SCREW M6 |
14 | BATTERY ASSEMBLY | |
14.1 | 503165 | BATTERY CABLE |
14.2 | 599606 | BATTERY TIE |
14.3 | 511019 | BATTERY |
15 | CARBON CANISTER ASSEMBLY | |
15.1 | 91325 | BOLT M6 |
15.2 | 94405 | FUEL LINE CLAMP |
15.3 | 94403 | FUEL LINE CLAMP |
15.4 | 91334 | BOLT M6 |
15.5 | 543301L | CARBON CANISTER |
15.6 | 503043 | BRACKET |
15.7 | 95016 | CARBON CANISTER AND AIR FILTER CONNECTING PIPE |
16 | BRACKET ASSEMBLY | |
16.1 | 91325 | BOLT M6 |
16.2 | 503006 | LIFTER |
16.3 | 503008 | BRACKET |
16.4 | 503009 | HANDLE |
16.5 | 503042 | BRACKET |
16.6 | 91330 | BOLT M6 |
17 | BRACKET ASSEMBLY | |
17.1 | 91325 | BOLT M6 |
17.2 | 503007 | LIFTER |
17.3 | 503008 | BRACKET |
17.4 | 503009 | HANDLE |
17.5 | 503011 | BRACKET |
17.6 | 91335 | BOLT M6 |
17.7 | 503790 | CONTROL MODULE |
17.8 | 90010 | NUT M6 |
17.9 | 91330 | BOLT M6 |
18 | FUEL TANK ASSEMBLY | |
18.1 | 503775 | FUEL TANK |
18.2 | 500008 | FUEL TANK ISOLATION PAD |
18.3 | 91322 | BOLT M5 |
18.4 | 500252 | SEALING RING |
18.5 | 95127 | CARBON CANISTER AND FUEL TANK CONNECTING PIPE |
18.6 | 500247 | GASOLINE SENSOR |
18.7 | 94405 | FUEL LINE CLAMP |
18.8 | 94403 | FUEL LINE CLAMP |
18.9 | 96801 | FUEL TANK GASKET |
18.10 | 91397 | BOLT M6 |
18.11 | 500244 | PRESS PLATE |
18.12 | 500324 | SEALING WASHER |
18.13 | 500068 | HANDLE PANEL PLUG |
18.14 | 503025 | PLUG |
18.15 | 503029 | FUEL SLOT |
18.16 | 503038-221 | TOP COVER |
18.17 | 92078 | SCREW M6 |
18.18 | 503028 | FUEL CAP |
18.19 | 518801 | FUEL TANK FILTER |
18.20 | 503782 | FUEL NOZZLE |
19 | 503805 | DEPUTY WIRING HARNESS |
20 | 503082 | BELLOWS |
21 | 99011 | SPARK PLUG SLEEVE |
22 | 500942 | FUNNEL |
23 | 99629 | OIL BOTTLE |
24 | 511043 | CHARGER |
25 | 99506 | DUAL - PURPOSE SCREWDRIVER |
26 | 503808 | DEPUTY WIRING HARNESS |
WestinghousePortablePower.com
Service Hotline: (855) 944-3571
777 Manor Park Drive
Columbus, OH 43228
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.