YOKOGAWA FU20 Instruction Manual
YOKOGAWA FU20 Instruction Manual

YOKOGAWA FU20 Instruction Manual

Ph/orp combination sensor
Hide thumbs Also See for FU20:

Advertisement

Quick Links

Instruction
Manual
Model FU20
pH/ORP Combination sensor
IM 12B06J03-02EN-P
st
1
edition

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FU20 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for YOKOGAWA FU20

  • Page 1 Model FU20 Instruction pH/ORP Combination sensor Manual IM 12B06J03-02EN-P edition...
  • Page 2 родния ви eзик, ce свържете c най- artículos antiexplosivos en su idioma local, близкия oфис или представителство на deberá ponerse en contacto con la oficina фирма Yokogawa. o el representante de Yokogawa más cercano. (CZ) Všechny uživatelské příručky pro výrobky, na něž se vztahuje nevýbušné schváleni Tous les manuels d’instruction des...
  • Page 3 Ex, deverá entrar em contacto com a delegação mais próxima (SLO) ou com um representante da Yokogawa. Vsi predpisi in navodila za AEX Ex sorodni pridelki so pri roki v anglišèini. Èe so Ex sorodna navodila potrebna v vašem tukejnjem jeziku, kontaktirajte vaš...
  • Page 4: Table Of Contents

    3.1 Typical installation .................... 21 3.2 Preparing the sensor for use ................21 3.3 Mounting the sensor ..................21 3.4 Mounting FU20 using quick removal adapters ..........22 3.5 Mounting the FU20 in PR10 retractable............23 4. DIMENSIONS......................25 5. WIRING ........................26 6.
  • Page 5: Preface

    SA11-P1 Smart Adapter, applications. which is placed directly on top of this connector, or remotely connected using The Model FU20 offers a simple and cost- the 3 meter WE10-H-D-003-V1 cable. effective solution for a wide variety of process applications. This all-in-one...
  • Page 6: Warranty And Service

    1.3 Warranty and Service 1.4 Serial number Yokogawa products and parts are The Serial number is defined by nine (9) guaranteed free from defects in alphanumeric characters: workmanship and material under normal Production location use and service for a period of (typically)
  • Page 7: General Specifications

    : 8 ± 15 mV Slope : > 96 % (of theoretical value) Note: The temperature sensor included in the FU20 is designed for process compensation and for indication. It is NOT designed for process temperature control. 2.4 Dynamic specifications Response time pH <...
  • Page 8: Shipping Details

    Graph 1: Pressure & Temperature range FU20 Note: The pH operating range at room temperature is 0-14 pH, but at high temperature or range outside 2-12 pH the lifetime will be seriously shortened. Note: The upper process temperature for the intrinsically safe version is limited by the ambient temperature (T .) defined for each temperature class (T3, T4, T5 and T6)
  • Page 9: Regulatory Standards

    Note 1: Models without ID-chip (with fixed cable or VP type): I/O signals are from/to an associated intrinsically safe certified pH/ORP transmitter (e.g. Yokogawa transmitter Model FLX21/FLX202 series or Yokogawa transmitter Model PH202S series). Models with ID-chip (VS type): I/O signals are from/to an associated intrinsically safe certified pH/ORP transmitter, Yokogawa Smart Adapter Model SA11-P1.
  • Page 10 This includes MS-code, serial number and process operating specifications. The intrinsic safety certification information of ATEX and IECEx is also written on the product label. Example of a product label see figure 1. FU20 XX-XX-XXX N3XA12345 Figure 1: Sensor product label...
  • Page 11 FM-United States Applying standards : FM Class 3600 FM Class 3610 FM Class 3810 ANSI/ISA 60079-0 ANSI/ISA 60079-11 Certificate no.* : FM20US0123X IS CL I, DIV 1, GP ABCD, T3…T6 CL I, ZN 0, AEx ia IIC, T3…T6 Ga Control Drawing: D&E 2020-023-A50 Electrical data : See Note 3 Specific conditions : See Control Drawing D&E 2020-023-A50...
  • Page 12 Control drawing: D&E 2020-023-A50 (part 1) IM 12B06J03-02EN-P...
  • Page 13 500 V rms. Sensor Model code: Table 3: Model Suffix Codes Option Codes FU20 -ab-cd-efg Connection type: Two alphanumeric characters identifying the length of the permanent cable, each character from 0 to 9 Connector without ID-chip...
  • Page 14 Control drawing: D&E 2020-023-A50 (part 2) IM 12B06J03-02EN-P...
  • Page 15 The sensor itself does not provide 500 V rms isolation from earth, the interconnecting equipment Model SA11-P1 Smart Adapter however provide this required isolation. Sensor Model code: Table 4: Model Suffix Codes Option Codes FU20 -ab-cd-efg Connection type: Connector with ID-chip Temperature sensor Pt1000, IS for ATEX/IECEx, FM-US, + Region: FM-CAN...
  • Page 16 FM-Canada Applying standards : CAN/CSA-C22.2 No. 60079-0 CAN/CSA-C22.2 No. 60079-11 Certificate no.* : FM20CA0062X IS CL I, DIV 1, GP ABCD, T3…T6 CL I, ZN 0, Ex ia IIC, T3…T6 Ga Control Drawing: D&E 2020-023-A51 Electrical data : See Note 4. Specific conditions : See Control Drawing D&E 2020-023-A51.
  • Page 17 Control drawing: D&E 2020-023-A51 (part 1) IM 12B06J03-02EN-P...
  • Page 18 500 V rms. Sensor Model code: Table 5: Model Suffix Codes Option Codes FU20 -ab-cd-efg Connection type: Two alphanumeric characters identifying the length of the permanent cable, each character from 0 to 9 Connector without ID-chip...
  • Page 19 Control drawing: D&E 2020-023-A51 (part 2) IM 12B06J03-02EN-P...
  • Page 20 Model SA11-P1 Smart Adapter however provide this required isolation. Sensor Model code: Table 6: Model Suffix Codes Option Codes FU20 -ab-cd-efg Connection type: Two alphanumeric characters identifying the length of the permanent cable, each character from 0 to 9 Connector with ID-chip...
  • Page 21: Installation Of Fu20

    3.2 Preparing the sensor for use For optimum measurement results, the Remove the sensor from its shipping box FU20 should be installed in a location that and slide of the so-called ‘wet pocket’, the offers an acceptable representation of the...
  • Page 22: Mounting Fu20 Using Quick Removal Adapters

    3.4 Mounting FU20 using quick removal adapters The FU20 can also be mounted using one of the optional quick-removal adapters (/NSS, /NTI, /BSS, /BTI, see Figure 5). For a detailed description of these adapters see Sections 4 and 7 of this Instruction Manual.
  • Page 23: Mounting The Fu20 In Pr10 Retractable

    4 Release the pigtail (cable gland) the cable and screw it onto the fixed completely. Do not undo the part in the part. metal tube! 8 Remove the tape. FIG. 6: Dimensional drawing PR10...-D32 with mounted FU20 sensor IM 12B06J03-02EN-P...
  • Page 24 FU20 + FD40 FU20 + PR10 Fitting /HCNF, SPRAY CLEANER O-ring Cleaning solution (water, acid, etc) Adapter (/FPS) K1547PH FU20 K1547PF O-ring 60mm Figure 7: Installation examples for the FU20 IM 12B06J03-02EN-P...
  • Page 25: Dimensions

    4. DIMENSIONS Dimensions in mm (inches) Figure 8: Dimensions FU20 Figure 9: Dimensions 1” FU20 adapter Stainless Steel & Titanium and FU20 adapter for FF40, FS40 and FD40 fittings IM 12B06J03-02EN-P...
  • Page 26: Wiring

    5. WIRING The FU20 sensor is provided with a fixed cable or a 8 pins Vario Pin connector (type VP without ID-chip and type VS with ID-chip). Table 7: Wire Pin D (yellow Item Wire color Description F (blue Transparent...
  • Page 27: General Calibration & Maintenance Procedure

    6. GENERAL CALIBRATION & MAINTENANCE PROCEDURE 6.1 Calibration for pH measurement To calibrate the FU20 pH/ORP sensor, two buffer solutions with known pH values are required. It is recommended that one buffer solution has a value near to pH 7.00.
  • Page 28: Maintenance Of The Fu20 Sensor

    6.3 Maintenance of the FU20 sensor A pH sensor requires routine maintenance to keep the measuring elements clean and functioning. Depending on the process, different cleaning solutions may be required. Avoid cleaning the complete sensor with solution. Some cleaning solutions will damage the model code sticker and connector which are placed on top of the sensor.
  • Page 29: Model Codes

    7. MODEL CODES Table 10: Model Option Suffix code Description Code code FU20 Wide body sensor Fixed cable, 3 meter not available Fixed cable, 5 meter for FTD, FTS Fixed cable, 10 meter Type & MTS Fixed cable, 20 meter Variopin connector →...
  • Page 30: Spare Parts

    8. SPARE PARTS Table 11: Spare part Description FU20 /FPS Adapter for FF40, FS40 and FD40 fittings K1523DD (PPO) /NSS 1” NPT, Stainless Steel adapter (Viton O- K1547PK ring) /BSS ISO 7/1-R1, Stainless Steel adapter (Viton K1547PL O-ring) /NTI 1” NPT, Titanium adapter (Viton O-ring)
  • Page 31: Chemical Compatibility Chart

    9. CHEMICAL COMPATIBILITY CHART Table12: Note: Information in this list is based on our general experience and literature data and given in good faith. However, Yokogawa is unable to accept responsibility for claims related to this information. IM 12B06J03-02EN-P...
  • Page 32 IM 12B06J03-02EN-P Printed in The Netherlands, 01-2101 Subject to change without notice Copyright © IM 12B06J03-02EN-P...

Table of Contents