Surface scattering light turbidity detector
Hide thumbs Also See for TB830D:

Advertisement

Quick Links

User's
Manual
TB830D
Surface Scattering Light Turbidity
Detector
Start-up and Safety Precautions
IM 12E04B40-01EN
IM 12E04B40-01EN
1st Edition

Advertisement

loading
Need help?

Need help?

Do you have a question about the TB830D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for YOKOGAWA TB830D

  • Page 1 User’s TB830D Manual Surface Scattering Light Turbidity Detector Start-up and Safety Precautions IM 12E04B40-01EN IM 12E04B40-01EN 1st Edition...
  • Page 2 Introduction Thank you for purchasing TB830D Surface Scattering Light Turbidity Detector. This User’s Manual contains all essential information for the user to make full use of TB830D. Please read the following respective documents before installing and using the instrument. The related documents are listed as follows.
  • Page 3 • No part of the user’s manuals may be transferred or reproduced without prior written consent from YOKOGAWA. • YOKOGAWA reserves the right to make improvements in the user’s manuals and product at any time, without notice or obligation. • If you have any questions, or you find mistakes or omissions in the user’s manuals, please contact our sales representative or your local distributor.
  • Page 4 Safety Precautions WARNING Installation and wiring The TB830D should only be used with equipment that meets the relevant IEC, American or Canadian standards. Yokogawa accepts no responsibility for the misuse of this unit. Don’t install “general purpose type” instruments in the hazardous area.
  • Page 5 The product is provided on an “as is” basis. YOKOGAWA shall have neither liability nor responsibility to any person or entity with respect to any direct or indirect loss or damage arising from using the product or any defect of the product that YOKOGAWA can not predict in advance. IM 12E04B40-01EN...
  • Page 6 Control of Pollution Caused by the Product This is an explanation for the product based on “Control of Pollution caused by Electronic Information Products” in the People’s Republic of China. 产品中有害物质的名称及含量 有害物质 部件名称 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr (VI))
  • Page 7 If damage is found, retain the original packing materials (including the outer box) and then immediately notify the carrier and the relevant Yokogawa sales office. Make sure the model and suffix code on the nameplate match your order and the necessary accessories are included.
  • Page 8 ● allows for drainage. For information on FLXA402T, read the user’s manual. Install the TB830D’s converter and detector unit in pipes, racks or walls using their special mounting brackets, respectively. Note that these mounting brackets are supplied only when specified. Refer to General Specifications (GS 12E04B40-01EN) for details.
  • Page 9 Pipe the sample, drainage, and washing water. If a sampling system is supplied with the product, connect the pipe to the sampling system. If the sampling system is not supplied, connect the pipe to TB830D detector. For proper operation of the instrument, the sample requirements, such as flow rate, have to be met.
  • Page 10 (51) C A+ (91) (53) NO RS485(-R) B− (92) Contact output (72) NO GND (93) (71) C (-WR) SHLD (94) (73) NC Ethernet(-E) Figure 2.3 Wiring for TB830D With sampling system (-A2, -A3) IM 12E04B40-01EN 1st Edition : Mar. 08, 2023-00...
  • Page 11 Figure 2.4 Wiring for TB830D without sampling system, with relay box (-A5) CAUTION Turn off power supply to TB830D before wiring. Power rating must comply with TB830D specifications. Power voltage must match with the one indicated on the name plate. WARNING ●...
  • Page 12 The minimum cross sectional area of the protective grounding wire should be 0.75 mm . For CSA safety standard (Standard: - AD), use cables with a cross section of 0.75 - 2.1 mm Wiring of TB830D WARNING Never let the power cable touch SENCOM cable, resulting in failure to comply with safety requirements.
  • Page 13 Ground Terminal Power Terminal Figure 2.7 Wiring of Terminal Box B Wiring of TB830D with Relay Box for connecting solenoid valve  Open the smart box. Connect the cable complying with the figure below. To Converter terminal To Detector terminal...
  • Page 14 Refer to the user’s manual IM 12E04B40-02EN for details. CAUTION Never use harsh chemicals or solvents. If the instrument does become heavily stained or scratched, you may need to replace some parts. Consult Yokogawa. Fuse  There is a circuit board mounted fuse protecting the instrument. If a fuse blows soon after the change, contact Yokogawa.
  • Page 15 <Start-up and Safety Precautions> Revision record Mar. 2023/ 1st Edition Newly released. IM 12E04B40-01EN 1st Edition : Mar. 08, 2023-00...
  • Page 16 <Start-up and Safety Precautions> Yokogawa Electric Corporation 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750, JAPAN http://www.yokogawa.com/ IM 12E04B40-01EN 1st Edition : Mar. 08, 2023-00...