Advertisement

Available languages

Available languages

Quick Links

Betriebsanleitung
Hochdruckkalibrator HPX
450565.0095

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LPX and is the answer not in the manual?

Questions and answers

Summary of Contents for Keller LPX

  • Page 1 Betriebsanleitung Hochdruckkalibrator HPX 450565.0095...
  • Page 2: Table Of Contents

    Inhaltsverzeichnis Ansicht Hinweise zur Betriebsanleitung 1. Gerätebeschreibung 2. Allgemeine Sicherheitshinweise 3. Bedienung des HPX-Kalibrators 4. Beschreibung der Funktionen 5. Menüführung Kalibratoren 6. Inbetriebnahme 7. Wartung / Entsorgung 8. Software für Kalibratoren Ersatzteile und Zubehör zu KELLER Druckkalibratoren Konformitätserklärung...
  • Page 3: Ansicht

    Ansicht 1 10 Anschluss Schnittstellenkabel K-104-A oder K-114-A (PC-Anschluss / RS485) Gerätesockel Anzeige Taste SELECT und ENTER Ölkammer Rückführleitung Verschlussschraube Handvordruckpumpe 9 Prüfling-Druckanschluss ohne Überdruckventil (700 bar) Ablassventil Schraubenkompressor...
  • Page 4: Hinweise Zur Betriebsanleitung

    Sollten Sie Probleme oder Fragen ACHTUNG! haben, wenden Sie sich an Ihren Der Prüfling muss frei von Anhaftun Bestimmungsgemässe Verwendung Lieferanten oder direkt an KELLER. gen jeglicher Art (Öl, Fett, Wasser…) Der Hochdruckkalibrator (HPX) darf sein. Verunreinigungen können über zur Druckerzeugung nur mit dem mit- den Adapter in den Hochdruckkalibra- geliefertem Hydrauliköl Typ HLP 22...
  • Page 5: Allgemeine Sicherheitshinweise

    (overflow) oder (underflow) auf 2. Allgemeine Sicherheitshinweise Druck abbauen der Anzeige. 1. Schraubenkompressor (11) voll- Bei allen Arbeiten sind die bestehen- ständig öffnen den nationalen Vorschriften zur Unfall- Wird ein Druck ausserhalb des Mess- 2. Ablassventil (10) öffnen verhütung und Sicherheit am Arbeits- bereiches des Gerätes angelegt, wird platz einzuhalten.
  • Page 6: Menüführung Kalibratoren

    SELECT-Taste ENTER-Taste Die frontseitig angebrachte Taste Die frontseitig angebrachte Funk- SELECT dient zum Einschalten, zur tionstaste ENTER dient zur Aktivie- Funktionsselektierung sowie zum An- rung der selektierten Funktion oder wählen der verschiedenen Druckein- Druckeinheit des Gerätes. Zudem heiten des Gerätes. kann durch drücken der ENTER-Taste zwischen bisher gemessenem Minimal- und Maximal druckwert...
  • Page 7: Wartung / Entsorgung

    Displayanzeige im Sekun- Wir empfehlen Ihnen den Ölwechsel dentakt zwischen der aktuell ver- Cont on : Deaktiviert die automa- durch KELLER vornehmen zu las- strichenen Messzeit [mm:ss] und der tische Ausschaltfunktion sen. Dabei wird zusätzlich das ganze bisher gemessenen Druckänderung.
  • Page 8 Kalibrator und Com- puter. Installieren Sie, bevor Sie den Schnittstellenkonverter mit dem Computer verbinden, Driver K-104 / K-114 (kostenloser Download unter www.keller-druck.com) Geräteeinstellungen des Hoch- druckkalibrators mit der Software ManoConfig Über die Software "ManoConfig" können Geräteeinstellungen wie z.B. Leak-Messzeit oder Abschaltzeit des Druckkalibrators angepasst werden.
  • Page 9: Ersatzteile Und Zubehör Zu Keller Druckkalibratoren

    9) EU Konformitätserklärung Das gelieferte Gerät erfüllt die gesetzlichen Anforderungen. Die angewandten Richtlinien und harmonisierten Normen sind in der für das Produkt gültigen EU / UK-Konformitätserklärung aufgeführt. Die EU / UK-Konformitätserklärung finden Sie unter www.keller-druck.com beim jeweiligen Produkt. Ersatzteile und Zubehör zu KELLER Druckkalibratoren passend zu Beschreibung Artikelnummer Abbildung Tragkoffer leer 309025.0005 Batterie Typ CR2430 557005.0001...
  • Page 10 Operating instructions for the high pressure calibrator (HPX) 450565.0095...
  • Page 11 2. General safety warnings 3. Operating the HPX calibrator 4. Description of the functions 5. Menu navigation for calibrators 6. Commissioning 7. Maintenance / disposal 8. Software for calibrators Spare parts and accessories for KELLER pressure calibrators Declaration of conformity...
  • Page 12: View

    View 1 10 Port for interface cable (K-104-A or K-114-A) (PC connection / RS485) Device base Display SELECT and ENTER buttons Oil chamber Recirculation pipe Screwed sealing plug Manual booster pump Pressure connection for test object, without overpressure valve (700 bar) Drain valve Screw compressor...
  • Page 13: Notes On The Operating Instructions

    The high pressure calibrator (HPX) IMPORTANT! consult KELLER directly. may only be used to generate pres- Nothing must adhere to the surface of sure with the type HLP 22 BP hydrau- the test object (no oil, grease, water, lic oil that is supplied with the product.
  • Page 14: Operating The Hpx Calibrator

    safety must be followed whenever last valid pressure value that was IMPORTANT! work is carried out. Internal regula- measured will flash on the display Do not open if there is high pressure in tions issued by the operator must (overload warning). the system! be followed, even if they are not mentioned in these instructions.
  • Page 15: Menu Navigation For Calibrators

    SELECT button ENTER button The SELECT button positioned on the The ENTER button positioned on front is used to switch the device on, the front is used to activate the se- to select a function and to select the lected function or pressure unit on the various pressure units.
  • Page 16: Maintenance / Disposal

    KELLER change the oil. The entire that has now elapsed [mm:ss] and the Cont on : Disables the automatic system is cleaned at the same time. pressure change measured thus far.
  • Page 17 You will find more informa- tion about the software in the CCS30 manual. Step-by-step software installation Install from www.keller-druck.com: 1.) K-104 / K-114 driver 2.) (CCS30) Control Center Series 30 3.) ManoConfig (if desired) ManoConfig...
  • Page 18: Spare Parts And Accessories For Keller Pressure Calibrators

    9) EU Declaration of Conformity The device supplied complies with the legal requirements. The relevant directives and harmonised standards are listed in the EU / UK Declaration of Conformity applicable to the product. You can find the EU / UK Declarations of Conformity by the relevant product at www.keller-druck.com. Spare parts and accessories for KELLER pressure calibrators suitable for Description Article number...
  • Page 19 Notice d’utilisation Calibrateur haute pression HPX 450565.0095...
  • Page 20 2. Rappels généraux de sécurité 3. Utilisation du calibrateur HPX 4. Description des fonctions 5. Guidage par menu de la calibration 6. Mise en service 7. Entretien / Recyclage 8. Logiciels de calibration Rechanges et accessoires pour calibrateurs de pression KELLER Déclaration de conformité...
  • Page 21: Vue De L'appareil

    Vue de l’appareil 1 10 Branchement du convertisseur K-104-A ou K-114-A (branchement d’un PC / RS485) Socle de l’appareil 3 Afficheur Touches SELECT et ENTER Chambre à huile Conduite de retour Bouchon de fermeture Pompe d’amorçage Raccord de pression du calibrateur, sans valve de surpression (700 bar) Valve de purge Vis de compression d’huile...
  • Page 22: Rappels Relatif À La Notice D'utilisation

    Utilisation conforme s’adresser à votre fournisseur ou soit (huile, graisse, eau…). Ces souil- Le calibrateur haute pression (HPX) directement à KELLER. lures risquent en effet d’être introduites ne doit être utilisé qu’avec de l’huile dans le calibrateur par l’adaptateur et HLP 22 BP fournie avec l’appareil pour...
  • Page 23: Rappels Généraux De Sécurité

    ment le chapitre « Maintenance » pour 2. Rappels généraux de sécurité Génération de la pression savoir comment procéder pour purger La mise en œuvre du calibrateur l’appareil. Les prescriptions nationales en vigueur s’effectue avec le bouchon de ferme- en matière de prévention des accidents ture (7) ouvert (de 2 ...
  • Page 24: Description Des Fonctions

    4. Description des fonctions Touche SELECT Touche ENTER La touche SELECT située sur la face La touche ENTER située sur la face Guidage par menu avant de l’appareil sert à la mise sous avant de l’appareil sert à l’activation Si la fonction ou l’unité sélectionnée n’a tension, à...
  • Page 25: Entretien / Recyclage

    Vidange de l’huile Nous recommandons de faire procéder Cont on  : désactive la fonction d’arrêt à la vidange par KELLER. Lors de cette automatique opération, nous nettoyons en effet l’en- semble du système. Utiliser exclusive- Cont oFF : active la fonction d’arrêt ment de l’huile hydraulique HLP 22 BP.
  • Page 26 être mémorisées ou exportées pour traitement ultérieur. Consulter le ma- nuel du CCS30 pour plus de détails. Mode opératoire de l’installation du logiciel Installer le logiciel par téléchargement sur le site www.keller-druck.com 1.) Pilote K-104 / K-114 2.) ControlCenterSerie30 (CCS30) 3.) le cas échéant ManoConfig ManoConfig...
  • Page 27 L‘appareil livré répond aux exigences légales. Les directives appliquées et les normes harmonisées sont mentionnées dans la déclaration UE / UK de conformité valable pour le produit. Vous trouverez la Déclaration UE / UK de conformité sur keller-druck.com pour le produit concerné. Rechanges et accessoires pour calibrateurs de pression KELLER convenant pour Description Référence de l’article...
  • Page 28 KELLER Druckmesstechnik AG KELLER Gesellschaft für Druckmesstechnik mbH Version | Edition CH-8404 Winterthur DE-79798 Jestetten 05/2024 +41 52 235 25 25 +49 7745 9214 0 info@keller-druck.com sales.eu@keller-druck.com www.keller-druck.com...

This manual is also suitable for:

MpxHpx

Table of Contents