Advertisement

Quick Links

Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide
Copyright © 2024 Tellabs
®
All Rights Reserved

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OLT2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Tellabs OLT2

  • Page 1: Tellabs® Olt2 Optical Line Terminal Description, Installation, And Turn Up Guide

    Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide Copyright © 2024 Tellabs ® All Rights Reserved...
  • Page 2: Tellabs® Information

    Information in this publication is subject to change without notice. Trademarks The following trademarks and service marks are owned by Tellabs Operations, Inc. or its affiliates in the United ® ®...
  • Page 3: Table Of Contents

    Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide........1 Tellabs® Information..........................2 Copyright................................2 Trademarks................................2 Proprietary................................2 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide....... 4 Description................................6 Site Preparation..............................16 Safety Precautions............................22 Installation................................. 25 OLT Installation................................26 Splitter Installation................................30...
  • Page 4: Tellabs® Olt2 Optical Line Terminal Description, Installation, And Turn Up Guide

    Note: This product is currently in Limited Availability and specifications will not be finalized until product General Availability.  INTRODUCTION This document provides instructions to install the Tellabs® OLT2 Optical Line Terminal (OLT2). The OLT2 is a self- contained and sealed unit, for mounting on a wall or in standard 19-in (48.3cm) size rack. This guide describes the 100−220 VAC powering, suggested mounting instructions and turn up and the initialization procedures for the OLT2.
  • Page 5 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide Next Page 5 of 56 © 2024,Tellabs Enterprise, Inc. All rights reserved.
  • Page 6: Description

    Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide Description Overview · General Features · PON Features · Interfaces · Management · Passive Optical Network · ITU-T G.984 2.5G PON · IP/Ethernet Network · Security · Software Support ·...
  • Page 7 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide OVERVIEW The Tellabs FlexSym OLT2 supports both ITU-T 984 G-PON and ITU-T G.9807/G.987 XGS-PON 10G connectivity to Optical Network Terminals (ONT). It provides flexible choices for designing a modern enterprise network to exactly align with contemporary connectivity such as IoT, wireless, ...
  • Page 8 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide GENERAL FEATURES The OLT2 is supplied with the following features: 2x PON Ports: The OLT2 supports 2x PON ports. The ports can be either GPON or XGS-PON. The PON modes · cannot be mixed.
  • Page 9 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide 512 UNIs per PON port · Map GEM ports and T-CONT with priority scheduling · Activation with automatic serial number discovery with password · Forward Error Correction (FEC) ·...
  • Page 10 · SECURITY  Tellabs has implemented unique advanced security features to protect enterprise networks. The ONT2 supports security across the optical distribution network and end-to-end over the OLAN system; such as encryption of traffic on the PON using the Advanced Encryption Standard AES-128 and Access Control Lists (ACL) at Layer 2 through 4 levels.
  • Page 11 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide 2x PON Ports: The OLT2 supports 2x PON ports. The ports can be either GPON or XGS-PON. The PON modes · cannot be mixed. 4x 10/1 SFP+ Ports: The OLT2 supports 4x OLT PON ports, typically intended to be daisy chained to support ·...
  • Page 12 Power for the OLT is supplied by a 150W Power Supply using an AC Power cord on one end or from a Network Powered System and an 8 pin Molex connector “A” or “B” power connector to the back of the OLT2. Two power supplies may be installed for a “redundant”...
  • Page 13 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide LED INDICATORS LED Indicators ACTV – Shows operational status of the system · FAIL – Shows functional status of the system · SFP+ LINK – Indicates the optical status of attached ONTs ·...
  • Page 14 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide OLT2 LED BEHAVIOR  Indications Comments FAIL Red Solid When the FAIL LED indication is Red Solid when powering on, the LED will remain illuminated during Initializing and downloading.  The LED will go dark when unit is in the operational state.
  • Page 15 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide Dark When the PON Link LED indication is dark, it indicates that no ONT serial numbers are provisioned on the PON and no unexpected ONTs are detected on the PON. Green Solid When the SPF+ Link LED indication is green solid.
  • Page 16: Site Preparation

    Agriculture Rural Utilities Service (RUS) Bulletin 1751F-810, and/or local practices, as applicable.  POWER AVAILABILITY Ensure that there is an available 100/220 VAC outlet within ten feet of the Tellabs OLT2 unit if powering with AC power supply 81.11P-PWIL150W. THE BOX CONTAINS OLT2 –...
  • Page 17 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide If multiple OLT2s are ordered, or optional accessories are ordered along with the OLT2, they may be packed in the same shipping container, or be shipped separately. The following table gives the OLT2 part numbers and accessories associated with the OLT2.
  • Page 18 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide WALL MOUNTING The OLT2 can be attached to a wall, or to some other surface using wall mounting brackets and screws. Fiber cable management guides are recommended to protect the fiber cable bend radius.
  • Page 19 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide RACK MOUNTING  When selecting the installation rack and its location, the following items should be considered as part of that selection: Elevated Operating Ambient – If installed in a closed or multi-unit rack assembly, the operating ambient ·...
  • Page 20 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide Figure 2: Dual Rack Mount POWER SUPPLY MOUNTING The power supply can be wall mounted with a snap in power supply mounting bracket when using the AC power supplies.
  • Page 21 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide Page 21 of 56 © 2024,Tellabs Enterprise, Inc. All rights reserved.
  • Page 22: Safety Precautions

    Warning! Do not open the enclosure unless directed to do so by Tellabs technical support. Doing so is dangerous and voids the warranty. Check that the DC power supply polarity is correct. The system will not be damaged by reversed polarity but ·...
  • Page 23 Electrostatic Discharge (ESD) Observe and follow all ESD instructions while handling Tellabs plug-in equipment. Caution! The Tellabs plug-in equipment uses semiconductor devices that can be damaged by electrostatic discharge (ESD). Do not remove   a plug-in from a protective packing box or equipment rack until time of installation or replacement. To equalize the static charge on the plug-in, establish a body path to ground using an ESD wrist strap connected to a ESD ground.
  • Page 24 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide Product Disposal The Waste Electrical and Electronic Equipment (WEEE) symbol (shown below) will accompany products that must be collected and disposed of separately from household waste. The black bar under the symbol signifies the product was placed on the market after August 13, 2005.
  • Page 25: Installation

    Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide Installation CONTENTS OLT Installation · Splitter Installation · Power Supply Installation · Previous    |   Next  Page 25 of 56 © 2024,Tellabs Enterprise, Inc. All rights reserved.
  • Page 26: Olt Installation

    UNPACKING AND CHECKING THE OLT2 The Tellabs OLT2 and related accessories to be installed may arrive in a single shipping box, or in multiple boxes. When unpacking the boxes, check each item against the installation work order for proper quantities and for shipping damage.
  • Page 27 1. Remove the rack mounting brackets from the OLT front panel and attach the brackets to the sides of the OLT. 2. Place the OLT2 on the surface it will be attached to. Position the bracket so that it will hold the OLT in the desired orientation.
  • Page 28 Installation in Rack Use the following instructions to install the Tellabs OLT2:  1. Insert the OLT2 shelf into the desired position and push it straight back until the mounting brackets are flush against the mounting rails. Secure the OLT2 shelf with four #12-24 screws. Inserting the two upper mounting screws first. Do not tighten the mounting screws until Step...
  • Page 29 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide b. Connect the chassis ground cable to the single-hole lug on the side of the OLT2 (Phillps M3.5 6 long), See Figure below. The terminating end of the chassis ground cable connection should be secured to the rack frame by using a ring connector (12-10 AWG).
  • Page 30: Splitter Installation

    Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide Splitter Installation Laser Safety Warning! Personnel handling fiber optic cables must be trained for laser safety. Warning! Optical Fibers emit invisible laser radiation. Avoid direct exposure to the beam. Never look into the end of a Fiber or into a Fiber connector on a cable or a device.
  • Page 31 Use the following procedure to verify and connect fiber optic cables between the OLT and the 2:32 fiber Splitter. Note 1: PON Protection Groups can be sourced from; 1) two PON ports on the Tellabs PON1, or 2) PON ports on different PON cards in different OLTs.
  • Page 32 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide 13. Calculate the difference between the Primary_In and the Secondary_In input power levels, plus an offset of 5db. 14. If the Primary_In power level is not greater than, or equal to, the Secondary_Inpower level, plus the 5db offset, add a 5db attenuator to the Secondary PON input.
  • Page 33: Power Supply Installation

    Power for the OLT is supplied by a 150W Power Supply (81.11P-PWIL150W) using an AC Power cord (81.11W-C5TYPB- R6) on one end and an 8 pin Molex connector “A” or “B” power connector on the back of the OLT2. Two power supplies may be installed for a “redundant”...
  • Page 34 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide 6. Connect the P1 connector to the OLT when directed in the Power Up section. POWER SUPPLY MOUNTING The power supply can be wall mounted with a snap in power supply mounting bracket ( 81.11K BKONTPS 150)
  • Page 35: Turnup And Initialization

    Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide TurnUp and Initialization Perform the following procedures to initialize and turn up the Tellabs® OLT2: Power Up · TurnUp · Check Power Level · Previous  |  Next Page 35 of 56...
  • Page 36: Power Up

    1. Insert the 8 pin molex power cable into the power input socket at the back of the Tellabs OLT2. Note: The Tellabs OLT2 does not have a power on/off switch, as it is not intended to power down the shelf while it is in service.
  • Page 37: Turnup

    OLT2 CONFIGURATION As shipped, the OLT2 is configured to facilitate quick and easy out of box setup and testing. This setup is designed to minimize the effort required to establish initial connectivity. Once connectivity to the OLT2 is established, it can be configured to conform to the current network deployment.
  • Page 38 Connect via SSHv2 The OLT2 is shipped with the default IP address 192.168.0.10. When an SFP is installed into any uplink port, this IP address can be used to access the OLT CLI using an untagged SSHv2 connection. It is recommended that the default IP address be changed to avoid a conflict with the next unit turned up.
  • Page 39 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide 2. Log into the OLT CLI. The initial username and password for the system is: admin/tellabs login as: _ Connect from xxx.xxx.xxx.xxx password for (admin): _ 3. On initial login, the administrative password must be changed. The system will prompt for the current Enter password in order to allow the change.
  • Page 40 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide Note2: CLI commands, parameters and options can be entered using abbreviations. The abbreviations are specified using capitalization in the help listings and context menus. For example, the wizard command is displayed in the help listing as .
  • Page 41 CLI. The goal of turnup is to initialize the system such that Panorama PON can be used to complete configuration. For the OLT2 by default from the factory puts all uplinks in a single LAG allowing communication / connection to the network when any of the links are plugged AID of Uplink Interface Accept the system default (NET1).
  • Page 42 OLT is added to Panorama PON. Note: Remember that the OLT2 is initially configured so that, all uplinks are in the NET1 interface. Additionally, the first module installed will determine the uplink speed. Any ports with modules of the same speed will be enabled. If you installed more than one module, entering one (1) here (as shown in the example) will disable all ports except the first port matching the link speed of the first module installed.
  • Page 43 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide 9. When the Wizard finishes gathering data, a summary is displayed for confirmation. To accept the Enter configuration and perform the turnup, input  at the prompt and press . The turnup configuration will be applied and the OLT restarted if necessary.
  • Page 44 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide Note: If you made a mistake during Turnup, input  at this prompt and the wizard will terminate without applying the turnup data entered. You can then relaunch the wizard to correct any mistakes. The next attempt should be faster as the wizard will use the responses from the last execution as defaults in each prompt.
  • Page 45: Check Power Level

    Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide Check Power Level Laser Safety Warning! Personnel handling fiber optic cables must be trained for laser safety. Warning! Optical Fibers emit invisible laser radiation. Avoid direct exposure to the beam. Never look into the end of a Fiber or into a Fiber connector on a cable or a device.
  • Page 46 8. Verify the optic levels from the table above using another quad fiber jumper. If the optic levels are not verified, this may indicate a bad quad fiber jumper or the Tellabs OLT2. Replace the quad fiber jumper, if required.
  • Page 47: Add Ont/Olt To Ems

    Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide Add ONT/OLT to EMS Add OLT · Add ONT · Previous   |   Next Page 47 of 56 © 2024,Tellabs Enterprise, Inc. All rights reserved.
  • Page 48: Add Olt

    1. Launch the Add OLAN OLT Wizard from the Main Menu by selecting Tools > Wizard > Add OLAN OLT 2. Enter the IP address of the OLT2 in the IP Address text field, select the ERASE configuration data from the...
  • Page 49 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide 3. If Panorama is able to communicate with the OLT, it will display a summary of its turnup data. Confirm the Next data and click the  button. 4. Enter the Target Identifier (TID) in the Target Identifier text box and enter the appropriate time zone data.
  • Page 50 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide Confirm and Apply 5. Click the  Button. Page 50 of 56 © 2024,Tellabs Enterprise, Inc. All rights reserved.
  • Page 51 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide Finish 6. Panorama will add the OLT. This will take a few minutes. When the add is completed, click the  button. Previous   |   Next Page 51 of 56 © 2024,Tellabs Enterprise, Inc. All rights reserved.
  • Page 52: Add Ont

    Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide Add ONT An ONT must be added to the EMS from the EMS GUI. This can be done in one of several ways: Configuration via the Unexpected ONT menus ·...
  • Page 53 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide All ONTs that have not been accepted onto the PON will be shown in the dialog and each can be configured and accepted onto the PON. The following editable fields are present: Configure (Y/N): Whether or not to configure the ONT.
  • Page 54 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide Manual Pre-Configuration The ONT can be pre-configured via the AddONT option of the EMS. The intent is that you would configure the ONT prior to installation and upon installation the unit would be automatically accepted and go into service without any further manual intervention.
  • Page 55 Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide Once selected, the user will be prompted to select the ONT type, the ONT serial number, ONT ID and User Label for the ONT. Auto Configuration and ONT Templates...
  • Page 56: Contacting Tellabs

    Tellabs® OLT2 Optical Line Terminal Description, Installation, and Turn Up Guide Contacting Tellabs TELLABS WARRANTY & REPAIR CENTER The Tellabs Repair Center is staffed Monday-Friday 6:00 AM-4:00 PM CT, excluding Tellabs company holidays.  If you have a technical or hardware emergency after hours, please contact the Tellabs TAC. Contacting Repair ...

Table of Contents