Download Print this page

Assa Abloy Corbin Russwin SN200 Series Installation Instructions Manual page 9

Wiegand/ osdp cylindrical lock
Hide thumbs Also See for Corbin Russwin SN200 Series:

Advertisement

SN200/210 CLX33600
Cylindrical Lock
SN210 OSDP Application Diagram #3 (12/24VDC System)
OSDP Operation Mode*:
*LED/Sounder control and Tamper status communicated over OSDP serial protocol
12V
Average
Reader*
75mA
Actuator
500mA
**Maximum AVG - RMS current draw during continuous card reads
Not evaluated by UL.
Peak - highest instantaneous current draw during RF communication
Reader Electronics Requires 12VDC Filtered and Regulated
Tamper will trigger when reader is removed from door and tamper
monitoring is enabled at the panel**
12/24VDC System
**NOTE: Tamper, LED and sounder, are controlled by OEM software
†IMPORTANT: Pin 7 must be tied to earth ground in the access
control panel.
Wiring in accordance with the NEC, ANSI/NFPA 70
Fail secure installations are subject to approval of local AHJ
Fail secure installations shall permit use of Listed panic
hardware to allow emergancy exit from the protected area.
Failure to follow proper ESD safe grounding procedures could
lead to equipment failure.
Copyright © 2023 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved.
Reproduction in whole or in part without the express written permission of ASSA ABLOY
Access and Egress Hardware Group, Inc. is prohibited.
5) Wiring Diagrams (Continued)
24V
Peak
Average
250mA
n/a
500mA
250mA
QC12 Electric
12 Conductor
Hinge From
ElectroLynx Harness
McKinney
From McKinney
For OSDP cable lengths greater than 200 ft
(61 m) or EMF interference, install 120Ω +/-
2Ω resistor across RS-485 termination ends.
PIN 8 (Yellow – n/a)
PIN 6 (Blue – RX COM)
PIN 4 (Green – RS-485A)
Peak
PIN 2 (Red – Reader POS)
n/a
250mA
PIN 1 (Black – Reader NEG)
PIN 3 (White – RS-485B)
PIN 5 (Orange – RX NO)
PIN 7 (Brown - EGND)
120 VAC
Input
READER NEG - Black, 1
READER POS - Red, 2
RS-485B - White, 3
RS-485A - Green, 4
RX (NO) - Orange, 5
RX (COM) - Blue, 6
†EARTH GROUND - Brown, 7
n/a - Yellow, 8
LOCK NEG - Violet, 9
LOCK POS - Gray, 10
DPS (NC) - Pink, 11
DPS (COM) - Tan, 12
9
PIN 4 (Tan –DPS COM )
PIN 2 (Gray – Lock POS)
PIN 1 (Violet – Lock NEG)
PIN 3 (Pink – DPS NC)
H N G
Power Supply
12-24VDC
12VDC
(By Others)
-
+
-
+
(-)
12VDC
(+)
RS-485B
RS-485A
RX (NO)
Use (NC) for
RX (COM)
Fail Safe
Operation
DPS
DPS
(NO) Fail
Secure
Operation
Panel Circuitry
(NC)
Panel Relay
(NO)
Electrical
Access
Control
Panel
(By Others)
Lock Relay

Advertisement

loading
Need help?

Need help?

Do you have a question about the Corbin Russwin SN200 Series and is the answer not in the manual?

Questions and answers