National Instruments ECUTS-16000 Safety, Environmental, And Regulatory Information

National Instruments ECUTS-16000 Safety, Environmental, And Regulatory Information

Hide thumbs Also See for ECUTS-16000:

Advertisement

Quick Links

ECUTS-16000
Safety,
Environmental,
and Regulatory
Information
04-2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECUTS-16000 and is the answer not in the manual?

Questions and answers

Summary of Contents for National Instruments ECUTS-16000

  • Page 1 ECUTS-16000 Safety, Environmental, and Regulatory Information 04-2022...
  • Page 2: Table Of Contents

    ECUTS-16000 Safety, Environmental, and Regulatory Information ECUTS-16000 Safety, Environmental, and Regulatory Information 24U ECU Test System Contents ECUTS-16000 Safety, Environmental, and Regulatory Information......3 Icons........................3 Safety........................3 EMC Guidelines...................... 7 Environmental Guidelines..................8 Protective Earthing....................9 Power Requirements..................... 9 Physical Characteristics..................10 Export Compliance....................11 Product Certifications and Declarations............
  • Page 3: Ecuts-16000 Safety, Environmental, And Regulatory Information

    ECUTS-16000 Safety, Environmental, and Regulatory Information ECUTS-16000 Safety, Environmental, and Regulatory Information Read this document and the documents listed in the Additional Resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards.
  • Page 4 • Observe 100 V peak working voltage and 500 V peak overvoltage limits for some instruments when integrated into the ECUTS. Refer to the ECUTS-16000 Specifications for details. • Hazardous voltage may be applied to some electronic load channels on J2. Load channels are isolated from each other, so hazardous voltage on one load channel does not imply that other load channels must be treated as hazardous.
  • Page 5 Do not connect the ECUTS-16000 to signals or use for measurements within Measurement Categories II, III, or IV. ATTENTION Ne connectez pas le ECUTS-16000 à des signaux et ne l'utilisez pas pour effectuer des mesures dans les catégories de mesure II, III ou IV. CAUTION Ensure that hazardous voltage wiring is performed only by qualified personnel adhering to local electrical standards.
  • Page 6 ECUTS-16000 Safety, Environmental, and Regulatory Information Measurement Category Measurement Category I CAUTION Do not connect the product to signals or use for measurements within Measurement Categories II, III, or IV. ATTENTION Ne pas connecter le produit à des signaux dans les catégories de mesure II, III ou IV et ne pas l'utiliser pour effectuer des mesures dans ces catégories.
  • Page 7: Emc Guidelines

    ECUTS-16000 Safety, Environmental, and Regulatory Information Safety Compliance Standards This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 61010-1, CSA C22.2 No. 61010-1...
  • Page 8: Environmental Guidelines

    ECUTS-16000 Safety, Environmental, and Regulatory Information NOTICE Refer to the individual instrument documentation for additional notices pertaining to specific cable, accessory, or other requirements to ensure specified EMC performance. NOTICE The length of all I/O cables must be no longer than 3 m (10 ft), except the rear Ethernet port.
  • Page 9: Protective Earthing

    ECUTS-16000 Safety, Environmental, and Regulatory Information Protective Earthing High levels of leakage current may be present on the ECUTS-16000. Connect the ECUTS-16000 protective earth terminal before connecting to AC power. NOTE The facility installation shall provide a means for connection to protective earth,...
  • Page 10: Physical Characteristics

    This value reflects the maximum weight of an ECUTS-16000 as configured by NI. The maximum weight of an ECUTS-16000, including user additions, must not exceed 453 kg (1,000 lbs). Contact NI for more information about the weight of your system.
  • Page 11: Export Compliance

    ECUTS-16000 Safety, Environmental, and Regulatory Information Keyboard tray 0.9 kg (2 lb) Human-Machine Interface Weight Keyboard tray 0.9 kg (2 lb) Monitor 3.5 kg (8 lb) Rack Paint Color RAL-7035 gray ESD dissipative paint as defined in Paint type IEC 61340-5-1 The circuit breaker on the power entry panel PEP-116 is rated for a mechanical impact energy level of IK06 (1 J), when tested with a direct vertical impact per IEC 61010-1, 3rd Ed.,...
  • Page 12 ECUTS-16000 Safety, Environmental, and Regulatory Information Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI. NI corporate headquarters is located at 11500 N Mopac Expwy, Austin, TX, 78759-3504, USA.
  • Page 13 For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data.