TC-IG 1100 Originalbetriebsanleitung Manual de instrucciones original Stromerzeuger Grupo Electrogeno Original operating instructions Alkuperäiskäyttöohje Power Generator Generaattori Instructions d’origine Оригинальное руководство по Générateur de courant эксплуатации электрический генератор Istruzioni per l’uso originali Generatore di corrente Originalna navodila za uporabo Električni generator...
Danger! be channeled directly outdoors through an When using the equipment, a few safety pre- exhaust hose. Important: Toxic exhaust gases cautions must be observed to avoid injuries and can escape despite the exhaust hose. Due to damage. Please read the complete operating the fire hazard, never direct the exhaust hose instructions and safety regulations with due care.
bustion engine are hot and can cause burns. which may be needed. Factors in uencing The warnings on the generating set must be the actual user immission level include the observed. properties of the work area, other sound sour- • If it is installed in ventilated rooms, the ad- ces etc., the number of machines and other ditional requirements relating to protection...
2.2 Items supplied applications. Our warranty will be voided if the Please check that the article is complete as machine is used in commercial, trade or industrial speci ed in the scope of delivery. If parts are businesses or for equivalent purposes. missing, please contact our service center or the sales outlet where you made your purchase at the latest within 5 working days after purchasing...
5. Before starting the equipment Important! When starting with the reserve starter, the motor may recoil suddenly as it starts up, resulting in 5.1 Electrical safety: • hand injuries. Wear protective gloves when star- Electric supply cables and connected equip- ting the equipment.
50 hours of operation. For our latest prices and information please go to • Pull off the spark plug boot with a twist. www.Einhell-Service.com • Remove the spark plug (Fig. 7/D) with the supplied spark plug wrench.
The reprinting or reproduction by any other me- ans, in whole or in part, of documentation and papers accompanying products is permitted only with the express consent of the Einhell Germany Subject to technical changes - 21 - Anl_TC_IG_1100_SPK9.indb 21...
10. Troubleshooting Fault Mögliche Ursache Behebung Engine does not Automatic oil cut-out has not respon- Check oil level, top up engine oil start Spark plug fouled Clean or replace spark plug (electro- de spacing 0.6 mm) No fuel Refuel / have the petrol cock checked Generator has too Controller or capacitor defective Contact your dealer...
* Not necessarily included in the scope of delivery! In the eff ect of defects or faults, please register the problem on the internet at www.Einhell-Service.com. Please ensure that you provide a precise description of the problem and answer the following questions in all cases: •...
Page 12
5. To make a claim under the guarantee, please register the defective device at: www.Einhell-Service.com. Please keep your bill of purchase or other proof of purchase for the new device. Devices that are returned without proof of purchase or without a rating plate shall not be covered by the guarantee, because appropriate identi...