Advertisement

Available languages

Available languages

Quick Links

8
Installation Guide
1

Advertisement

Table of Contents
loading

Summary of Contents for OBSIDIAN CONTROL SYSTEMS NETRON EN6 IP

  • Page 1 Installation Guide...
  • Page 2 ©2024 OBSIDIAN CONTROL SYSTEMS all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. Obsidian Control Systems logo and identifying product names and numbers herein are trademarks of ADJ PRODUCTS LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted.
  • Page 3: Table Of Contents

    C O N T E N T S GENERAL INFORMATION LIMITED WARRANTY IP65 RATED SAFETY GUIDELINES CONNECTIONS INSTALLATION INSTRUCTIONS MAINTENANCE SPECIFICATIONS DIMENSIONS FCC STATEMENT...
  • Page 4: General Information

    These instructions contain important safety and use information. The Netron EN6 IP is a powerful Art-Net and sACN to DMX gateway with six RDM compatible ports in a rugged IP66 rated chassis. It is designed for live productions, movie sets, temporary outdoor installations, or interior use with long term protection from humidity, dust and debris.
  • Page 5: Limited Warranty

    (including negligence), misrepresentation, strict liability, breach of warranty of Elation or Obsidian Control Systems or any supplier, and even if Elation or Obsidian Control Systems or any supplier has been advised of the possibility of such damages.
  • Page 6 I P 6 6 R AT E D The International Protection (IP) rating system is commonly expressed as “IP” (Ingress Protection) followed by two numbers (i.e. IP65), where the numbers define the degree of protection. The first digit (Foreign Bodies Protection) indicates the extent of protection against particles entering the fixture, and the second digit (Water Protection) indicates the extent of protection against water entering the fixture.
  • Page 7: Safety Guidelines

    This device is a sophisticated piece of electronic equipment. To guarantee a smooth operation, it is important to follow all instructions and guidelines in this manual. OBSIDIAN CONTROL SYSTEMS is not responsible for injury and/or damages resulting from the misuse of this device due to the disregard of the information printed in this manual.
  • Page 8: Connections

    C O N N E C T I O N S AC CONNECTION The Obsidian Control Systems NETRON EN6 IP is rated 100-240V. Do not connect it to power outside this range. Damage resulting from incorrect connection is not covered under warranty.
  • Page 9 CONNEC TI O NS System Menu Control Panel Cover M12 Mounting Hole Mounting Bracket 5pin XLR DMX/RDM optically isolated Safety Cable ports (3-6) Bidirectional for DMX In/Out Full Color DMX Port Attachment Point OLED Display Indicator LEDs ACT/LINK Indicator LEDs Waterproof Touch Buttons: Menu return, Up, Down, Enter Valve...
  • Page 10: Installation Instructions

    I N S TA L L AT I O N I N S T R U C T I O N S DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE! ELECTRICAL CONNECTIONS A qualified electrician should be used for all electrical connections and/or installations. USE CAUTION WHEN POWER LINKING OTHER MODEL DEVICES AS THE POWER CONSUMPTION OF OTHER MODEL DEVICES MAY EXCEED THE MAXIMUM POWER OUTPUT OF THIS DEVICE.
  • Page 11 I N S TA L L AT I O N I N S T R U C T I O N S TRUSS MOUNTED WITH CLAMP This unit can be truss mounted using either an M10 or M12 bolt. For the M12 bolt, as shown on the left, simply insert the bolt through a properly rated mounting clamp, then thread the bolt into the matching mounting hole on the side of the device and tighten securely.
  • Page 12 I N S TA L L AT I O N I N S T R U C T I O N S WALL MOUNTED Flip the device over to expose the mounting holes on the bottom face. Align the circular holes on the wide flange section of each Wall Mounting Bracket (included) to the Mounting Holes on each side of the device, then insert the screws (included) to secure the wall Mounting Brackets in place.
  • Page 13: Maintenance

    M A I N T E N A N C E The Obsidian Control Systems Netron EN6 IP is designed as rugged, roadworthy device. The only required service is periodic cleaning of external surfaces. For other service-related concerns, please contact your Obsidian Control Systems dealer, or visit www.obsidiancontrol.com.
  • Page 14: Specifications

    S P E C I F I C AT I O N S Mounting: Standalone Truss-mount (M10 or M12) Wall-mount Connections: Front: Full color OLED display Status feedback LEDs 4 menu select buttons Bottom Locking IP65 Power In/Thru Fuse Holder Vent Left: (2) 5pin IP65 DMX/RDM optically isolated ports...
  • Page 15: Dimensions

    D I M E N S I O N S...
  • Page 16: Fcc Statement

    F C C S TAT E M E N T FCC Class A Warning: Please note that changes or modifications of this product that are not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
  • Page 18 Guide d'installation...
  • Page 19 Le logo Obsidian Control Systems et les noms et numéros d’identification des produits dans le présent document sont des marques commerciales d’ADJ PRODUCTS LLC. La protection du droit d’auteur revendiquée comprend toutes les formes et toutes les questions de matériel...
  • Page 20 C O N T E N U INFORMATIONS GÉNÉRALES GARANTIE LIMITÉE CLASSÉ IP65 LIGNES DIRECTRICES DE SÉCURITÉ CONNEXIONS INSTRUCTIONS D’INSTALLATION MAINTENANCE CARACTÉRISTIQUES DIMENSIONS DÉCLARATION DE LA FCC...
  • Page 21: Informations Générales

    Ces instructions contiennent des informations importantes sur la sécurité et l’utilisation. Le Netron EN6 IP est une puissante passerelle Art-Net et sACN vers DMX avec six ports compatibles RDM dans un châssis robuste classé IP66. Il est conçu pour les productions en direct, les plateaux de tournage, les installations temporaires en extérieur ou pour une utilisation intérieure avec une...
  • Page 22: Garantie Limitée

    Obsidian Control Systems conclut, après inspection, qu’elle affecte la fiabilité du produit ; si le produit a été réparé ou entretenu par quelqu’un d’autre que l’usine Obsidian Control Systems, à moins qu’une autorisation écrite préalable n’ait été délivrée à l’acheteur par Obsidian Control Systems ; si le produit est endommagé...
  • Page 23 C L A S S É I P 6 6 Le système d’évaluation de la protection internationale (IP) est communément exprimé par “IP” (Ingress Protection) suivi de deux chiffres (c’est-à-dire IP65), où les chiffres définissent le degré de protection. Le premier chiffre (Protection contre les corps étrangers) indique le degré...
  • Page 24: Lignes Directrices De Sécurité

    Cet appareil est un équipement électronique sophistiqué. Pour garantir un bon fonctionnement, il est important de suivre toutes les instructions et directives de ce manuel. OBSIDIAN CONTROL SYSTEMS n’est pas responsable des blessures et/ou des dommages résultant d’une mauvaise utilisation de cet appareil en raison du non-respect des informations imprimées dans ce manuel.
  • Page 25 C O N N E X I O N S COUPLAGE AC Le NETRON EN6 IP d’Obsidian Control Systems est classé 100-240V. Ne le connectez pas à une alimentation en dehors de cette plage. Les dommages résultant d’une connexion incorrecte ne sont pas couverts par la garantie.
  • Page 26: Connexions

    CONNEXI ON S Couvercle du panneau de commande du menu système M12 Trou de montage Support de fixation Ports DMX/RDM XLR 5 broches optiquement isolés (3-6) bidirectionnels pour entrée/sortie DMX Affichage OLED LED d'indication Point de fixation du polychrome du port DMX câble de sécurité...
  • Page 27: Instructions D'installation

    I N S T R U C T I O N S D ’ I N S TA L L AT I O N DÉBRANCHEZ L’ALIMENTATION AVANT D’EFFECTUER TOUTE MAINTENANCE ! CONNECTIONS ELECTRIQUES Un électricien qualifié doit être utilisé pour toutes les connexions et/ou installations électriques.
  • Page 28 I N S T R U C T I O N S D ’ I N S TA L L AT I O N MONTÉ SUR TREILLIS AVEC PINCE Cette unité peut être montée sur une ferme à l’aide d’un boulon M10 ou M12. Pour le boulon M12, comme illustré...
  • Page 29 I N S T R U C T I O N S D ’ I N S TA L L AT I O N MONTÉ AU MUR Retournez l’appareil pour exposer les trous de montage sur la face inférieure. Alignez les trous circulaires de la large section de bride de chaque support de montage mural (inclus) avec les trous de montage de chaque côté...
  • Page 30: Maintenance

    M A I N T E N A N C E Les systèmes de contrôle Obsidian NETRON EN6 IP sont conçus comme des appareils robustes et en état de rouler. Le seul service requis est le nettoyage occasionnel. Pour d’autres problèmes liés au service, veuillez contacter votre revendeur Obsidian Control Systems ou visiter www.obsidiancontrol.
  • Page 31 S P É C I F I C AT I O N S MONTAGE: Standalone Montage sur ferme (M10 ou M12) Montage mural CONNEXIONS: Devant: Écran OLED couleur LED de retour d’état 4 boutons de sélection de menu Verrouillage de l’alimentation IP65 Porte-fusible Évent Gauche:...
  • Page 32: Dimensions

    D I M E N S I O N S...
  • Page 33 D É C L A R AT I O N F C C Avertissement de classe A de la FCC : Veuillez noter que les changements ou modifications de ce produit qui ne sont pas expressément approuvés par la partie responsable de la conformité peuvent annuler l’autorité de l’utilisateur à utiliser cet équipement.

Table of Contents