R3G280-AF42-62
4.4 Connection diagram
Drawing preliminary!
No.
Conn.
Designation
1
1, 2
PE
1
3
N
1
4
L
1
5
COM
1
6
NC
2
8
0 -10 V
2
10
P
2
11
10 VDC
2
12
GND
Item no. 51834-5-9970 · ENU · Change 273261 · Approved 2022-11-21 · Page 9 / 12
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Arrow.com.
Arrow.com.
Arrow.com.
Arrow.com.
Arrow.com.
Arrow.com.
Arrow.com.
Arrow.com.
Arrow.com.
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Operating instructions
Color
Function/assignment
green/
Protective earth
yellow
blue
Power supply, neutral conductor, see nameplate for voltage range, 50/60 Hz
black
Power supply, phase, see nameplate for voltage range, 50/60 Hz
white 1
Floating status contact, break for failure (2 A, max. 250 VAC, min. 10 mA)
white 2
Floating status contact, break for failure
yellow
Control input, set value 0-10 VDC, impedance 100 kOhm, SELV
orange
not used
red
Voltage output 10 VDC (±3%), max. 10 mA, power supply for external devices (e.g.
potentiometers), SELV
blue
Reference ground for control interface, SELV