Overview Of Pin Assignment For Fixed Functional Block; Overview Of Pin Assignment For Flexible Functional Block - Dimplex WPM Touch +2 Box Installation Manual

Extension box
Table of Contents

Advertisement

English

4.2.2 Overview of pin assignment for fixed functional block

1
function block 0
grey
Function
General / 1st
A1
unmixed circuit
K22
+A400

4.2.3 Overview of pin assignment for flexible functional block

Function block I
Function block II
Function block III
Function block IV (Accessories)
Function block V (Accessories)
Function
Domestic hot water +A420
1st mixed circuit +A411
2nd mixed circuit +A412
3rd mixed circuit +A413
Bivalent +A441
Renewable +A442
Swimming pool +A430
Cooling active +A451
Passive cooling +A452
Solar +443
Example: Pin assignment selection when the
domestic hot water function is selected for the
yellow function block
First of all, the function to be used (here domestic hot water)
and the function block to be assigned in terms of colour (here
yellow) are selected. In the table in the domestic hot water row,
the component to be connected is now selected, for example
the domestic hot water sensor R3. In the 1st row, the pin to be
assigned from the yellow function block is then selected. In this
Function block I
Function block II
Function block III
Function block IV (Accessories)
Function block V (Accessories)
Function
Domestic hot water +A420
1st mixed circuit +A411
HINWEIS
NOTE
You can find the detailed electrical documentation in the ac-
cessories pack
8
2
3
4
5
grey
grey
grey
grey
A2
R1
R2.2
M13
K23
1
2
yellow
yellow
green
green
red
red
orange
orange
blue
blue
K31
B3
-
-
-
-
-
-
-
-
-
-
-
B4
N5
K28
N5
K28
-
R22
1
2
yellow
yellow
grün
grün
rot
rot
orange
orange
blau
blau
K31
B3
-
-
452117.66.36-EN · FD 0301
Pin number
6
7
8
grey
grey
grey
grey
E10.2
H5
-
N27.1
K20
Pin number
3
4
5
yellow
yellow
yellow
green
green
green
red
red
red
orange
orange
orange
blue
blue
blue
R3
-
(Y)M18
R35
-
M13
R5
-
M15
R21
-
M20
-
-
E10.2/3
R13
-
-
R20
-
M19
R24.2
R39
N9/M17
R11
R4
M12
R23
-
M24
case the R3 domestic hot water sensor is to be connected to
the yellow pin with the number 3. This process is to be selected
for each component to be connected.
HINWEIS
NOTE
During commissioning of the system via the touch display, the
function to be used with the applicable colour assignment is
queried and set.
Pin number
3
4
yellow
yellow
yellow
grün
grün
green
rot
red
orange
orange
orange
blau
blau
blue
R3
-
(Y)M18
R35
-
HINWEIS
NOTE
Communication and control voltage cables are to be laid be-
tween a wall-mounted heat pump manager and the heat
pumps
WPM Touch +2 Box
9
10
11
12
grey
grey
grey
N27.2
-
-
6
7
yellow
yellow
green
green
red
red
orange
orange
blue
blue
M24
E9/K21
M21
M21
M22
M22
M29
M29
M26
M26
M27
M27
-
K36
Y12
Y12
Y5/Y6
M17
Y11
-
5
6
7
yellow
yellow
grün
grün
rot
rot
rot
orange
orange
blau
blau
M24
E9/K21
M13
M21
M21
www.dimplex.de
13
14
grey
grey
M16
M16
AO
8
yellow
green
red
orange
blue
M18 AO
-
-
-
-
-
M19 AO
-
-
-
8
yellow
grün
rot
orange
blau
M18 AO
-

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WPM Touch +2 Box and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents