Installation and connection
e
Product can only be installed and connected
in accordance with the statutory installation
rules.
Electrical connection
Connect the product to a grounded outlet/line
protected by a fuse of suitable capacity as stated
in the "Technical specifications" table. Have the
grounding installation made by a qualified
electrician while using the product with or
without a transformer. Our company shall not be
liable for any damages that will arise due to
using the product without a grounding installation
in accordance with the local regulations.
DANGER:
The product must be connected to the
mains supply only by an authorised and
qualified person. The product's
warranty period starts only after correct
installation.
Manufacturer shall not be held responsible
for damages arising from procedures
carried out by unauthorised persons.
The power cable must not be clamped,
bent or trapped or come into contact
with hot parts of the product.
A damaged power cable must be replaced
by a qualified electrician. Otherwise, there is
risk of electric shock, short circuit or fire!
e
Connection must comply with national
regulations.
e
The mains supply data must correspond to
the data specified on the type label of the
product. Open the front door to see the type
label.
e
Power cable of your product must comply
with the values in "Technical specifications"
table.
DANGER:
Before starting any work on the
electrical installation, disconnect the
product from the mains supply.
There is the risk of electric shock!
Connecting the power cable
1. If a power cable is not supplied together
with your product, a power cable that you
would select from the table in accordance
with the electrical installation at your home
must be connected to your product by
following the instructions in cable diagram.
This product must only be connected by a
qualified electrician such as a technician from
the local electricity company or NICEIC registered
contractor to a suitable double-pole control unit
with a minimum contact clearance of 3 mm in all
poles. This control unit must be installed
accordance with the IEE regulation. Failure to
obey this instruction may cause operational
problems and invalidate the product warranty.
»
"Additional protection by a residual
current circuit breaker is
recommended.
2. Open the terminal block cover with a
screwdriver,
3. Insert the power cable through the cable
clamp below the terminal and secure it to the
main body with the integrated screw on cable
clamping component.
4, Connect the cables according to the supplied
diagram.
SUPPLY CORD
i
5. After completing the wire connections, close
the terminal block cover.
6. Route the power cable so that it will not
contact the product and get squeezed
between the product and the wall.
[Power cable must not be longer than 2
m because of safety reasons.
13/EN