Have all checks and work on electrical
parts performed by an qualified technician.
The motor (suction turbine) does not
start up
No electrical voltage present
 Check the socket and the power supply
fuse.
 Check the mains cable and the mains
plug of the device.
The suction power decreases
Nozzle, suction hose or suction pipe
clogged.
 Check the nozzle, the suction hose and
the suction pipe and clean if necessary.
The filter is dirty.
 Clean the filter.
Emptying the liquid container takes a
long time
The drain hose is kinked or blocked.
 Check and, if necessary, clean the drain
hose.
Electrical connection
Mains voltage
Phase
Power frequency
Degree of protection
Protection class
Nominal power
Power protection (slow-blowing)
Dimensions and weights
Typical operating weight
Length x width x height
Ambient conditions
Ambient temperature
Device performance data
Tank content
Air quantity
Vacuum
Nominal width of the suction hose
Customer Service department
If the malfunction cannot be corrected, the
device must be checked by the Customer
Service department.
The warranty conditions issued by our rele-
vant sales company apply in all countries.
We shall remedy possible malfunctions on
your appliance within the warranty period
free of cost, provided that a material or
manufacturing flaw is the cause. In a war-
ranty case, please contact your dealer (with
the purchase receipt) or the next author-
ised customer service site.
(See overleaf for the address)
Further warranty information (if available)
can be found in the service area of your lo-
cal Kärcher website under "Downloads".

Technical data

V
~
Hz
W
A
kg
mm
°C
l
l/s
kPa
(mbar)
English

Warranty

IVR-L 400/24-2 Tc
220-240
1
50-60
IPX4
I
2400
16
201
1730 x 805 x 1390
+40
400
2 x 74
23 (230)
DN50
17