Specifications - Hayward ProChem Single Quick Start Manual

Hide thumbs Also See for ProChem Single:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
EN

Specifications

Power supply
Consumption
Pump flow rate
Max. back-pressure
Pump state
Measure scale
Device precision
Accuracy
Probe calibration
Weight
Dimensions
Default parameters
n
Item
1
Language
2
Set Point value
3
Dosing method
4
OFA Time
5
Calibration
6
Circulation pump
7
Flow Input
8
Power ON Delay
9
Flow Delay
SPECIFICATIONS
Value
EN
7.4 pH
700 mV
Acid (pH)
Low (Redox)
OFF
Full
ON
NO (normally open)
OFF
OFF
0000139394 ProChem Single | pH · ORP
PRO-CHEM-SPH / PRO-CHEM-SRXG
230 VAC 50-60 Hz
20 Watt
1.5 l/h
1.5 bar
Pause – Supply
0.0 ÷ 14.0 pH; 0 ÷ 1000 mV
± 0.1 pH; ±10mV
±0.02pH, ±2mV
Automatic
1 Kg
W: 120, H:258, D:135 mm
Measure alarm ranges default parameters
n
Item
1
Temp. Measure min
2
Temp. Measure Max
3
pH Measure
4
pH Measure
Max
5
ORP Measure min
6
ORP Measure Max
Page 4 on 20
Limits
+ 10°C
+ 38°C
min
6 pH
8.0 pH
+450 mV
+850 mV