Advertisement

Quick Links

Rainwater Harvesting
Installation
manual
Platin XL Tank

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Platin XL and is the answer not in the manual?

Questions and answers

Summary of Contents for Graf Platin XL

  • Page 1 Rainwater Harvesting Installation manual Platin XL Tank...
  • Page 2: General Notes

    GRAF must be used. GRAF offers an extensive range of accessories, all of which are designed to match each other and which can be extended to form complete systems. The use of accessories that have not been approved by GRAF results in the exclusion of the warranty/guarantee.
  • Page 3: Technical Data

    TECHNICAL DATA 2.1 Technical Data Platin XL / Connection option DN150 *Telescopic dome shaft at maximum height Maxi telescopic Mini telescopic dome shaft dome shaft *Telescopic dome shaft at minimum height 2.2 Overview tanks Platin XL Tank 10,000 litres 15,000 litres Art.
  • Page 4 TECHNICAL DATA 2.3 Technical Data Platin XL / Connection option DN100 *Telescopic dome shaft at maximum height Maxi telescopic Mini telescopic dome shaft dome shaft *Telescopic dome shaft at minimum height 2.4 Overview tanks Platin XL Tank 10,000 litres 15,000 litres Art.
  • Page 5: Tank Structure

    Telescopic dome shaft (can be inclined by 5º) Profile seal - Telescopic dome shaft Tank dome (can be rotated by 360º)  Tank seal - Tank dome Tank dome sealing plug Platin XL tank      ...
  • Page 6: Installation And Assembly

    Subsoil Telescopic dome shaft Compact foundation Surrounding (round-grained gravel, maximum grain size 10/20) Covering layer Platin XL Underground Tank Concrete layer for surfaces used by passenger cars ß ––> DIN 4124 from 1250mm depth of the trench DIN 4124 ...
  • Page 7 (See table for max. immersion depth). Dissipation of the drainage water (e.g. via an annular drainage system) is recommended in the case of cohesive, water-impermeable soils. Tank 10000 litres 15000 litres Max. immersion 1250 mm 1250 mm depth Graf UK Ltd...
  • Page 8 If you have any questions in this regard, please contact your Graf UK team. 4.10 Installation adjacent to surfaces used by vehicles If the underground tanks are installed adjacent to...
  • Page 9 INSTALLATION AND ASSEMBLY 4.11 Connection of several tanks Two or more tanks are connected via the assembly surfaces by means of GRAF special seals and basic pipes (to be provided at the construction site). The apertures must be drilled to the corresponding size using only the GRAF special crown bit.
  • Page 10 Drainage straight as possible, without solution bending, to the tank with a decline. Necessary bend must be formed using 30º moulded sections. Important: The empty pipe must be connected to an aperture above the max. water level. Graf UK Ltd...
  • Page 11: Assembling The Telescopic Dome Shaft

    The cover is then positioned and is sealed to prevent entry by children. Tighten the threaded connection on the cover so tightly that it cannot be opened by a child! Graf UK Ltd...
  • Page 12 Afterwards push the telescopic dome shaft onto the extension and adjust it to the planned area surface. max. earth-cover 1500mm Telescopic dome shaft (can be inclined by 5º) Extension Tank dome (can be rotated by 360º) Graf UK Ltd...
  • Page 13: Inspection And Servicing

    Separate installation instructions are enclosed in the transportation packaging for all additional articles purchased from GRAF. The components must be checked for any damage prior to installation under all circumstances. Missing instructions can be downloaded on www.graf.info or can be requested from GRAF. Graf UK Ltd...
  • Page 14 NOTES Graf UK Ltd...
  • Page 15 NOTES Graf UK Ltd...
  • Page 16 W A T E R B U T T S & C O M P O S T E R S M U L T I P U R P O S E C O N T A I N E R S Graf UK Ltd Graf UK Ltd (Scotland) Regen House 220 Blairtummock Road...

Table of Contents