2.1.2 Operation Mode Setting Switches

Normal use
Mode
(Factory default)
Switch setting
SW1
OFF
Operation when selecting the memory clear menu display
[Clear Memory] menu is displayed by selecting the memory clear menu display and turning
the power supply on.
Press [GT Data] to clear data in the user memory.
Press [Holding Data] to clear data in the hold memory.
Press [PLC Backup Data] to clear data backed up using the PLC backup/restore function.
When memory clear is complete, "Cleared" is displayed.
For resetting the condition to the normal use, turn off the power supply, change the operation
mode setting switches to the normal use mode, and turn on the power supply again.
REFERENCE
For information on the data stored in the user memory or hold memory, refer to 5.1.2
Performance Specifications.
Ramco Innovations
Inhibit system
menu shift
SW2
SW1
SW2
OFF
OFF
ON
www.panasonicsensors.com
Reserved for
Memory clear
system
menu display
(Usage prohibited)
SW1
SW2
SW1
ON
OFF
ON
(800) 280-6933
SW2
ON