Panasonic GT703 User Manual

Programmable display
Hide thumbs Also See for GT703:
Table of Contents

Advertisement

Quick Links

WUME-GT703H-01
2017.07
panasonic.net/id/pidsx/global
PROGRAMMABLE DISPLAY
GT703/GT704
User's Manual
Hardware

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic GT703

  • Page 1 PROGRAMMABLE DISPLAY GT703/GT704 User's Manual Hardware WUME-GT703H-01 2017.07 panasonic.net/id/pidsx/global...
  • Page 2: Safety Precautions

    Copyright / Trademarks - This manual and its contents are copyrighted. - You may not copy this manual in whole or part, without written consent of Panasonic Industrial Devices SUNX Co., Ltd. - Microsoft, Windows, Windows Vista, Windows7, Windows8 and Windows10 are trademarks or registered trademarks of Microsoft Corporation in the United States and other countries.
  • Page 3 Types of Manual • There are different types of users manual for the GT703/GT704 series. Please refer to a relevant manual for the functions and purpose of your use. • The manuals can be downloaded on our website: http://industrial.panasonic.com/ac/e/dl_center/manual/...
  • Page 4: Table Of Contents

    Tools Required for Screen Creation ............1-4 1.2.2 Software Usage Environment and Applicable Cables ......1-4 2. Names and Functions of Parts ......... 2-1 Names and Functions of Parts............... 2-2 2.1.1 GT703...................... 2-2 2.1.2 GT704...................... 2-3 2.1.3 Operation mode setting switches ............2-4 2.1.4 Terminal Layouts of COM Port ..............
  • Page 5 Table of Contents 3.1.6 Installing in Vertical Orientation ............... 3-5 Wiring the Power Supply ............... 3-6 3.2.1 Precautions on Wiring ................3-6 3.2.2 Wiring the Power Supply ................. 3-6 3.2.3 Wiring the COM Port ................3-7 3.2.4 Grounding ....................3-9 Precautions when Wiring COM Port ............
  • Page 6 5.2.1 About Error Codes ................... 5-7 5.2.2 GT703/GT704 Series Error Codes ............5-7 5.2.3 When Connected to Panasonic FP series PLC ........5-10 5.2.4 When Connected to PLC (FX series) Made by Mitsubishi Electric Corporation .................... 5-10 5.2.5 When Connected to PLC Made by Omron Corporation ......5-11 5.2.6...
  • Page 7 Performance Specifications ..............6-8 6.2.3 Function Specifications ................6-9 6.2.4 Interface Specifications ................. 6-10 Dimensions ..................6-12 6.3.1 GT703 Main Unit ................... 6-12 6.3.2 GT704 Main Unit ................... 6-13 Cable Specifications................6-14 6.4.1 AIGT8160 / AIGT8162 / AIGT8165 ............6-14 6.4.2 AIGT8175 ....................
  • Page 8: Before You Start

    Before You Start Before You Start  Usage conditions • Ambient temperature: 0 to +50 °C • Ambient humidity should be 20 to 85% RH (at 25 °C) and non-condensing. • Usable altitude: 2000 m above sea level or lower •...
  • Page 9 Before You Start  Touch switches • Always operate the touch switches with fingers. As the touch switches may be damaged due to the excessive load or shock (caused when being operated with any tools), the touch switches should be operated within the specified control force. Also, if the touch switches are pressed like kneading, the electrode may be worn out exceptionally, and cause the malfunction.
  • Page 10 Before You Start viii...
  • Page 11: System Configuration

    System Configuration...
  • Page 12: List Of Models

    RS422 slot 3-color LED backlight Silver AIG704WGNMS2 (RS485) (Green, red, orange) (Note): As for the 5 V DC type GT703, the power cannot be supplied from the tool port of a PLC (CPU unit). Prepare an external power supply separately.
  • Page 13: Options

    Appearance Product Item name Specifications Cable for connecting to tool AIGT8162 port of Mini-DIN 5-pin loose- AIGT8165 Panasonic FP series PLC wire cable (except FP7) AIGT8160 Cable for connecting to tool Mini-DIN 8-pin loose- port of AIGT8175 wire cable Mitsubishi FX series PLC...
  • Page 14: Screen Creation Tool

    Description Configurator WD IP address search tool Address setting for GT in Ethernet communication Note) The software can be downloaded on our website: (http://industrial.panasonic.com/ac/e/dl_center/software/). (User registration is required. Free of charge)  Screen transfer cable (Cable for connecting a PC)
  • Page 15: Names And Functions Of Parts

    Names and Functions of Parts...
  • Page 16: Names And Functions Of Parts

    Names and Functions of Parts 2.1 Names and Functions of Parts 2.1.1 GT703  GT703M / GT703G  Names and Functions of Parts Name Functions Various screens are displayed here. Switches can be operated and data entered ① Touch screen simply by touching the touch screen.
  • Page 17: Gt704

    2.1 Names and Functions of Parts 2.1.2 GT704  GT704M/GT704G  Names and Functions of Parts Name Functions Various screens are displayed here. Switches can be operated and data entered ① Touch screen simply by touching the touch screen. A sheet is affixed to the touch panel to protect it from scratches when shipping.
  • Page 18: Operation Mode Setting Switches

    Names and Functions of Parts 2.1.3 Operation mode setting switches Inhibit system Normal use Memory clear Inhibit system Inhibit menu shift & Mode (Factory default) menu display menu shift Ethernet shift Inhibit Ethernet use Switch setting SW1 SW2 SW3 SW4 SW1 SW2 SW3 SW4 SW1 SW2 SW3 SW4 SW1 SW2 SW3 SW4 SW1 SW2 SW3 SW4 OFF OFF OFF OFF OFF ON ON ON OFF ON OFF OFF OFF OFF ON OFF OFF ON ON OFF ...
  • Page 19: Terminal Layouts Of Com Port

    2.1 Names and Functions of Parts 2.1.4 Terminal Layouts of COM Port  GT703  5V / RS232C type Pin name Name Signal direction Product no. - - Functional ground - AIG703WMN1B5 Send Data AIG703WMN1S5 GT → External device AIG703WGN1B5 Receive data GT ←...
  • Page 20 Names and Functions of Parts  GT704  24V / RS232C type Pin name Name Signal direction Product no. +24V - - Functional ground - AIG704WMN1B2 Send Data AIG704WMN1S2 GT → External device AIG704WGN1B2 Receive data GT ← External device AIG704WGN1S2 Send request GT →...
  • Page 21: Connection With Screen Creation Tool Gtwin

    Communication with our software such as GTWIN becomes available by connecting to a PC with a USB cable.  Functions enabled by USB connection • Through function using Panasonic PLCs • Screen transfer If more than one programmable display unit are connected to a PC using the...
  • Page 22: Ethernet Port

    Names and Functions of Parts 2.2.2 Ethernet port Ethernet connections GT703/GT704 has an Ethernet port. Communication with our software such as GTWIN becomes available by connecting to a PC with a LAN cable. Remote communication is available by communicating with LAN cable.
  • Page 23 2.2 Connection with Screen Creation Tool GTWIN  Required items for connection • LAN cable Either straight cable or crossing cable can be used. (MDI/MDI-X Auto-crossover function)  Ethernet communication setting Follow the procedure below to communicate with the Ethernet connection. 1.
  • Page 24 The settings of the GT can be specified with the IP address search tool of Configurator WD (Ver.1.74 or later). The IP search tool (Config WD.exe) can be downloaded for free from our website. URL: http://industrial.panasonic.com/ac/e/dl_center/software/ (User registration is required.: Free of charge) 2-10...
  • Page 25: Installation And Wiring

    Installation and Wiring...
  • Page 26: Installation

    Installation and Wiring 3.1 Installation 3.1.1 Installation Environment When installing and using the GT series, always make sure the following conditions are observed.  Usage conditions • Ambient temperature: 0 to +50 °C • Ambient humidity should be 20 to 85% RH (at 25 °C) and non-condensing. •...
  • Page 27: Mounting Direction

    3.1 Installation 3.1.2 Mounting Direction The GT703/GT704 can be used in a vertical orientation and installed in a horizontal orientation. There is no difference in the operating ambient temperature due to the mounting orientation. Conditions Ambient temperature Horizontally installed GT703 / GT704 0 to 50 °C...
  • Page 28: Installation Method

    Installation and Wiring 3.1.5 Installation Method Secure the GT to the installation panel using the fittings and screws (4 sets/per unit) provided with the unit. PROCEDURE 1. Place the GT main unit in the installation panel. 2. Insert the fittings into the grooves provided in the GT main unit, and tighten the screws to secure the GT main unit to the installation panel.
  • Page 29: Installing In Vertical Orientation

    3.1.6 Installing in Vertical Orientation • The GT series can be installed upright. The power supply connector is placed on the top side as illustrated below. • Select the vertical type when selecting a GT model in GTWIN. GT703 back view GT704 back view...
  • Page 30: Wiring The Power Supply

    Installation and Wiring 3.2 Wiring the Power Supply 3.2.1 Precautions on Wiring • Perform wiring and placement of the cable so that there is no impression of external noise on the cable and no induction. • This product conforms to EN61131-2 for the European EMC Directive 2014/30/EU. The conformity conditions are as below.
  • Page 31: Wiring The Com Port

    3.2 Wiring the Power Supply 3.2.3 Wiring the COM Port  Accessory communication connector/applicable wiring The communication connector used for the COM port (provided as an accessory with the main unit) has a screw-tightening type of terminal block. Use the following items for wiring. ...
  • Page 32 Installation and Wiring  Wiring method (1) Remove a portion of the wire’s insulation. (2) Insert wire into terminal hole until it stops. Tighten screw clockwise to fix wire in place.  Precautions concerning wiring The following precautions should be observed, to avoid broken or disconnected wires. •...
  • Page 33: Grounding

    3.2 Wiring the Power Supply 3.2.4 Grounding Be sure to ground when the influence of noise is great The unit is tolerant against noise in normal environments, but if the environment is particularly susceptible to noise, please ground. Use dedicated grounding •...
  • Page 34: Precautions When Wiring Com Port

    Installation and Wiring 3.3 Precautions when Wiring COM Port 3.3.1 RS232C Communication • Perform wiring and placement of the cable so that there is no impression of external noise on the cable and no induction. • Use shielded wires for distribution cables. (Recommended cable: AIGT8162) •...
  • Page 35: Rs422 (Rs485) Communication

    3.3 Precautions when Wiring COM Port 3.3.2 RS422 (RS485) Communication • There is no RS and CS (control lines). • Perform wiring and placement of the cable so that there is no impression of external noise on the cable and no induction. •...
  • Page 36: Battery For Clock

    Installation and Wiring 3.4 Battery for Clock 3.4.1 Battery for Clock • For using the clock function built-in the GT, a battery for the clock should be mounted. Even when the power supply is off, the clock works.  Battery for clock Item name Appearance Specifications...
  • Page 37: Lifetime And Time For Replacement Of Battery For Clock

    Battery life, when operating at a normal temperature (25 °C), a normal humidity (65% RH), is as follows. GT Model Life GT703 / GT704 Approx. 5 years  Detection of battery error (1) Battery mark • Battery life is detected when the power of the GT turns OFF and ON. When clock data is not held, a battery mark can be displayed on the screen.
  • Page 38: Options

    Installation and Wiring 3.5 Options 3.5.1 Time for Replacement of Battery When replacing the battery for the clock, turn on electricity for the time for energization, and replace the battery with a new one within one minute after turning off the power supply. If the battery is not replaced within the replacing time, the clock will be initialized.
  • Page 39: Waterproof Packing

    3.5 Options 3.5.3 Waterproof Packing  About the Waterproof Packing If the panel is being detached from the GT and then reattached, the waterproof packing should be replaced, in order to assure that the panel remains waterproof IP67.  Replacing the waterproof packing Remove the currently attached waterproof packing.
  • Page 40 Installation and Wiring 3-16...
  • Page 41: Connection With Plc

    Connection with PLC...
  • Page 42: Connection With Plc

     Connection method with PLC Applicable Configuration Remarks PLCs by RS232C various 1:1 communication manufacturers PLCs by various 1:1 communication manufacturers Panasonic FP multiple series, 1: n connection RS422/485 communication Panasonic (Max. 31 FP7 series units) Panasonic FP series, GT Link...
  • Page 43: Plc Multiple Connection

    4.1 Connection with PLC 4.1.1 PLC Multiple Connection PLC multiple connection function is a function that enables more than one PLCs to connect with one GT using RS485 communication or Ethernet communication. For the RS485 communication, up to 31 PLCs can be connected. For the Ethernet communication, up to 64 PLCs can be connected.
  • Page 44: Connection With Other Companies' Plcs

    <GT series General-purpose Serial Communication Manual ARCT1F356E> 4.1.5 Precautions concerning the Power Supply of 5 V DC type As for the 5 V DC type GT703, the power cannot be supplied from the tool port of a PLC (CPU unit). Prepare an external power supply separately.
  • Page 45: Rs232C Connection

    4.2 RS232C Connection 4.2 RS232C Connection 4.2.1 RS232C Connection with PLC TOOL Port  Connecting to the TOOL port Usable models PLC communication cable Programmable display FP-X AIGT8162 FPΣ Mini-DIN 5-pin loose-wire 5V DC AIGT8165 RS232C type FP0 / FP0R cable 24V DC AIGT8160...
  • Page 46: Rs232C Connection With Fp-X Com Port

    Connection with PLC 4.2.2 RS232C Connection with FP-X COM Port  Connecting to the COM port of FP-X Communication cassette Usable models communication Programmable display cable AFPX-COM1 AFPX-COM2 5V DC FP-X AFPX-COM3 Loose-wire cable RS232C type 24V DC AFPX-COM4 AFPX-COM5 ...
  • Page 47 4.2 RS232C Connection  Connecting to 1-channel RS485 type and 1-channel RS232C type  Connecting to 1-channel Ethernet type and 1-channel RS232C type...
  • Page 48: Rs232C Connection With Fpσ Com Port

    Connection with PLC 4.2.3 RS232C Connection with FPΣ COM Port  Connecting to the COM port Usable models PLC communication cable Programmable display 5 V DC Loose-wire cable RS232C type FPΣ 24V DC  Connecting to 1-channel RS232C type  Connecting to 2-channel RS232C type As for the connection to S2 and R2, make the same connection as that of S1 and R1.
  • Page 49 4.2 RS232C Connection  Connecting to 1-channel RS485 type and 1-channel RS232C type The connections with either one unit or two units are available.
  • Page 50: Rs232C Connection With Fp0 / Fp0R Com Port

    Connection with PLC 4.2.4 RS232C Connection with FP0 / FP0R COM Port  Connecting to the COM port Usable models PLC communication cable Programmable display 5V DC RS232C type RS232C type FP0R 24V DC  Connecting to the COM port of FP0 / FP0R 4-10...
  • Page 51: Rs232C Connection With Fp2 / Fp2Sh Com Port

    4.2 RS232C Connection 4.2.5 RS232C Connection with FP2 / FP2SH COM Port  Connecting to the COM port FP2 / FP2SH CPU FP2 Multi Communication Unit Usable models PLC communication cable Programmable display CPU unit 5V DC D-SUB 9-pin loose- Communication AIP81842 RS232C type...
  • Page 52: Wirings Between Gt Series And Fp7

    Connection with PLC 4.2.6 Wirings Between GT series and FP7  Wiring between FP7 COM0 port and GT series (24V/RS232C type)  Wiring between FP7 COM0 port and GT series (5V/RS232C type)  Wiring between FP7 communication cassette AFP7CCS1 (RS232C 1-ch insulated type) and GT series (RS232C type) 4-12...
  • Page 53 4.2 RS232C Connection  Wiring between FP7 communication cassette AFP7CCS2 (RS232C 2-ch insulated type) and GT series (RS232C type) Set the on-board switch of AFP7CCS2 to “3Wire”. 4-13...
  • Page 54: Rs422 Connection

    Connection with PLC 4.3 RS422 Connection 4.3.1 RS422 Connection with FP-X COM Port Usable models communication Programmable display cable 5V DC type FP-X AFPX-COM3 Loose-wire cable RS422 / RS485 type 24V DC type  Connecting to FP-X communication cassette 1-channel RS485/RS422 type 4-14...
  • Page 55: Rs422 Connection With Fp2 / Fp2Sh Com Port

    4.3 RS422 Connection 4.3.2 RS422 Connection with FP2 / FP2SH COM Port  Connecting to the COM port Usable models Programmable PLC communication cable display Communication FP2 Multi D-SUB 9-pin loose- 5V DC RS422 block AIP81842 Communication Unit wire cable 24V DC /RS485 type FP2-CB422...
  • Page 56: Wirings Between Gt Series And Fp7

    Connection with PLC 4.3.3 Wirings Between GT series and FP7  Wiring between FP7 communication cassette AFP7CCM1 (RS-422/RS-485 1-ch insulated type) and GT series (RS-422/RS-485 type) (RS422 connection)  Wiring between FP7 communication cassette AFP7CCM2 (RS-422/RS-485 2-ch insulated type) and GT series (RS-422/RS-485 type) (RS-422 connection) 4-16...
  • Page 57 4.3 RS422 Connection Setting of FP7 Set the on-board switches of each cassette to "RS-422". For RS-422 connection, set the termination resistance switches of each cassette to “ON”. 4-17...
  • Page 58: Rs485 Connection

    Connection with PLC 4.4 RS485 Connection 4.4.1 RS485 Connection with FP0R COM Port  Connecting to the COM port Usable models communication Programmable display cable 5V DC FP0R RS485 type Loose-wire cable RS422 / RS485 type 24V DC  Connecting to the COM Port of FP0R 4-18...
  • Page 59: Rs485 Connection With Fp-X Com Port

    4.4 RS485 Connection 4.4.2 RS485 Connection with FP-X COM Port Usable models PLC communication Programmable display cable AFPX-COM3 5V DC type FP-X AFPX-COM4 Loose-wire cable RS422 / RS485 type 24V DC type AFPX-COM6  Connecting to FP-X communication cassette 1-channel RS485/RS422 type 4-19...
  • Page 60 Connection with PLC Confirm the usable GT models for the PLC multiple connection and GT link.  Connecting to 1-channel RS485 type and 1-channel RS232C type Confirm the usable GT models for the PLC multiple connection and GT link. 4-20...
  • Page 61 4.4 RS485 Connection  Connecting to 2-channel RS485 type Confirm the usable GT models for the PLC multiple connection and GT link. 4-21...
  • Page 62: Rs485 Connection With Fpσ Com Port

    Connection with PLC 4.4.3 RS485 Connection with FPΣ COM Port  Connecting to the COM port PLC communication Programmable display cable AFPG803 5V DC type Loose-wire cable RS422 / RS485 type FPΣ 24V DC type AFPG806  Connecting to 1-channel RS485 type Confirm the usable GT models for the PLC multiple connection and GT link.
  • Page 63 4.4 RS485 Connection  Connecting to 1-channel RS485 type and 1-channel RS232C type Confirm the usable GT models for the PLC multiple connection and GT link. 4-23...
  • Page 64: Rs485 Connection With Fp2 / Fp2Sh

    Connection with PLC 4.4.4 RS485 Connection with FP2 / FP2SH Usable models PLC communication Programmable display cable Communication FP2 Multi 5V DC type RS422 block Loose-wire cable Communication Unit 24V DC type /RS485 type FP2-CB485 Connecting to the FP2 Multi Communication Unit (MCU) + Communication block (RS485) Confirm the usable GT models for the PLC multiple connection and GT link.
  • Page 65: Wirings Between Gt Series And Fp7

    4.4 RS485 Connection 4.4.5 Wirings between GT series and FP7  Wiring between FP7 communication cassette AFP7CCM1 (RS-422/RS-485 1-ch insulated type) and GT series (RS-422/RS-485 type) (RS-485 connection) 1:1 connection PLC multiple connection GT link function 4-25...
  • Page 66 Connection with PLC  Wiring between FP7 communication cassette AFP7CCM2 (RS-422/RS-485 2-ch insulated type) and GT series (RS-422/RS-485 type) (RS-485 connection) 1:1 connection Note) As for the PLC multiple and GT link function connections, refer to the connection diagrams in the previous page. 4-26...
  • Page 67 4.4 RS485 Connection Setting of FP7 Set the on-board switches of each cassette to "RS-485". For RS-485 connection, set the termination resistance switches of each cassette to “ON”. 4-27...
  • Page 68: Precautions When Communicating With Rs485

    Connection with PLC 4.4.6 Precautions When Communicating With RS485 When communication with the RS485, the transmission line for sending and receiving data is the same. (1) Time taken until the connected device sends a response after sending a command from the GT: If a response is sent too quickly, the GT may not be able to receive it.
  • Page 69: Communication With Plc

    4.5 Communication with PLC 4.5 Communication with PLC 4.5.1 Automatic Communication Settings Function After turning on the power supply, if there is no response from the PLC connected to the COM. port, the GT switches to the automatic setting mode for the communication conditions. In the automatic setting mode, commands are sent to the PLC while changing the communication conditions in the sequence shown below.
  • Page 70: Through Function

    Always set the setting on the PLC side to match “Computer Link”. 4.5.2 Through Function In GT series, the through function enables to perform communication between a Panasonic PLC connected to the COM port or Ethernet port of the GT and a PC connected to the TOOL (USB) port of the GT.
  • Page 71 4.5 Communication with PLC  Procedure of making communication settings when using the through function 1. Match the communication settings of GT series to those of our PLC. The setting method of the GT series is as follows. For details of the setting method of our PLCs, refer to “4.5.3 PAGE”...
  • Page 72 (2) Select “Browse for driver software on your computer” and specify a folder for storing the driver in the “Update Driver Software” dialog box. [Driver storage folder] • For Windows (64-bit edition) \Program Files(x86)\Panasonic-ID SUNX Terminal\GTWIN_V3\GTWIN_USB\x64 • For Windows (32-bit edition) \Program Files\Panasonic-ID SUNX Terminal\GTWIN_V3\GTWIN_USB\x86 For details of "Update Driver Software", rear to "Procedure of installing USB...
  • Page 73 4.5 Communication with PLC 3. Set the network type of FPWIN. When using FPWIN GR (1) Select “Option (O)” > “Communication Settings (C)” from the menu bar. (2) Set the network type to “USB(GT)”. When using FPWIN GR7 (1) Select “Online (L)” > “Communication Settings (C)” from the menu bar. (2) Set the computer communication port to “USB(GT)”.
  • Page 74: Communication Settings Of Plc Using Fpwin Gr7

    Connection with PLC 4.5.3 Communication Settings of PLC using FPWIN GR7 Please read below to make PLC communication settings using the FPWIN GR. (1) Select “PLC system register setting” from the Option menu (O). (2) Make the communication settings. Select “Tool Port” setting when connecting to the tool port or “COM Port” setting when connecting to the COM port.
  • Page 75: Communication Settings Of Plc Using Fpwin Gr7

    4.5 Communication with PLC 4.5.4 Communication Settings of PLC using FPWIN GR7 Please read below to make PLC communication settings using the FPWIN GR7. (1) Select “Options (O)” > “FP7 Configuration (C)” > “Built-in SCU”. (2) Make the communication settings. Set the communication settings of the communication port connected to the GT to be the same as those of the GT.
  • Page 76 Connection with PLC 4-36...
  • Page 77: Troubleshooting

    Troubleshooting...
  • Page 78: What To Do If An Error Occurs

    Troubleshooting 5.1 What to Do If an Error Occurs Error Cause Solution Check the power within the specifications is Power is not on. supplied. Check the capacity of the power supply unit if it is The power voltage may be low. enough for the GT’s power consumption.
  • Page 79 5.1 What to Do If an Error Occurs Error Cause Solution No screen number has been written to the screen setting Specify a correct screen number. area (the first word in the basic communication area word device) from the PLC. Screen doesn’t The screen number to which switch.
  • Page 80 Troubleshooting Error Cause Solution Bit F of the first word in the Buzzer sounds basic communication area bit continuously. device is set to ON. Refer to the basic communication area map and The backlight flashing flag or check the operation of the bit allocated to PLC. Backlight color the backlight enable flag of the changes/flashes.
  • Page 81 5.1 What to Do If an Error Occurs  Operation security function Message Cause Solution “Incorrect password.” Is displayed An unregistered Enter the registered password. on the login screen. password was entered. An incorrect password “Incorrect password.” Is displayed was entered in the Enter the registered password correctly.
  • Page 82 Troubleshooting  When using an SD memory card Data may be erased or the SD memory card may be damaged during the operation. Take measures for the situations as below. Error Solution Transmitting GT configuration setting file using the logging function clears the information on the RAM.
  • Page 83: Error Codes And How To Handle Them

    5.2.1 About Error Codes When an error occurs in the GT series, an error code displays at the top right of the screen. There are two types of error codes, GT703/GT704 series error codes and PLC error codes. 5.2.2 GT703/GT704 Series Error Codes The following error codes are displayed when there is an error in the GT.
  • Page 84 Troubleshooting Code no. Error Cause and solution SD memory card recognition The SD memory card cannot be recognized. Check the SD **1006 error memory card used. Check if the PLC program for transfer matches the destination **1020 PLC model unmatch error PLC.
  • Page 85 5.2 Error Codes and How to Handle Them Code no. Error Cause and solution The unit number that the The bit in the connected GT designation area corresponding to the connected GT designation **2000 station number of the connected GT is not on. Check the area error setting has been connected GT designation area.
  • Page 86: When Connected To Panasonic Fp Series Plc

    Troubleshooting 5.2.3 When Connected to Panasonic FP series PLC Error codes which are sent from the PLC are listed in the table below. For details, refer to the table of MEWTOCOL-COM communication errors in PLC user’s manuals. Code no. Error Cause and solution Settings of the communication condition may be wrong.
  • Page 87: When Connected To Plc Made By Omron Corporation

    5.2 Error Codes and How to Handle Them 5.2.5 When Connected to PLC Made by Omron Corporation Code no. Error Cause and solution Cannot be executed due to operation mode. ER0001 Change the PLC mode from operation to monitor mode. (The PLC received a command that cannot be executed n the operation mode.)
  • Page 88: When Performing General-Purpose Serial Communication

    Troubleshooting 5.2.8 When Performing General-purpose Serial Communication Error code Error name Countermeasures The value of BCC may be incorrect. Check if there is no **0000 BCC error calculation mistake. **0001 Format error A command format may be incorrect. Check if it is correct. A command used is not supported with the version of the GT.
  • Page 89: Specifications

    Specifications...
  • Page 90: Gt703 Specifications

    Specifications 6.1 GT703 Specifications 6.1.1 General Specifications Specifications Item 24 V DC type 5V DC type Rated voltage 24 V DC 5 V DC Operating voltage 4.5 to 5.5 V DC 21.6 to 26.4 V DC range Power consumption 2.4 W or less (100 mA or less).
  • Page 91: Performance Specifications

    6.1 GT703 Specifications 6.1.2 Performance Specifications Item Specifications Display device TFT monochrome LCD Number of Dots 480 (W) x 192 (H) dots Displayable area 88.5 (W) x 35.4 (H) mm Display GT703M: 3-color LED backlight (White, red, pink) (Note 1)
  • Page 92: Function Specifications

    Programs of Panasonic FP series PLCs can be uploaded/downloaded via SD memory cards. PLC backup/ Programs and registers of a Panasonic FP series PLC connected to the COM port can restore function be backed up in the GT internal memory.
  • Page 93: Interface Specifications

    (Baud rate: 19,200 bit/s) (Baud rate: 115,200 bit/s) Terminal resistance value 120Ω - Protocol for Panasonic FP series PLC (MEWTOCOL) Protocol for Panasonic FP7 series PLC (MEWTOCOL7) General-purpose serial (Panasonic dedicated protocol) Protocol Modbus RTU mode protocol (Master/Slave) Other companies' PLC protocols For the details, refer to the latest GTWIN HELP.
  • Page 94  SD memory card Item Specifications SD memory card, SDHC memory card Support media (Note 1) (The manufacturer that the operation check has done: Panasonic Corporation) Conforms to SD standard Supported format standard (Please format with a format software for SD memory cards.) (Note 1): Check the usable temperature range of a SD memory card to be used before use.
  • Page 95: Gt704 Specifications

    6.2 GT704 Specifications 6.2 GT704 Specifications 6.2.1 General Specifications Specifications Item 24V DC type Rated voltage 24V DC Operating voltage 21.6 to 26.4V DC range Power consumption 2.4 W or less (100 mA or less). Operating ambient 0 to +50 °C temperature Operating ambient 20 to 85% RH (at 25 °C), non-condensing...
  • Page 96: Performance Specifications

    Specifications 6.2.2 Performance Specifications Item Specifications Display device TFT monochrome LCD Number of Dots 640 (W) x 240 (H) dots Displayable area 108.8 (W) x 40.8 (H) mm GT704M: 3-color LED backlight (White, Display (Note red, pink) Backlight GT704G: 3-color LED backlight (Green, red, orange) Can be adjusted on the menu screen and GTWIN configuration Backlight...
  • Page 97: Function Specifications

    Programs of Panasonic FP series PLCs can be uploaded/downloaded via SD memory cards. PLC backup/ Programs and registers of a Panasonic FP series PLC connected to the COM port can restore function be backed up in the GT internal memory.
  • Page 98: Interface Specifications

    (Baud rate: 19,200 bit/s) (Baud rate: 115,200 bit/s) Terminal resistance value 120Ω - Protocol for Panasonic FP series PLC (MEWTOCOL) Protocol for Panasonic FP7 series PLC (MEWTOCOL7) General-purpose serial (Panasonic dedicated protocol) Protocol Modbus RTU mode protocol (Master/Slave) Other companies' PLC protocols For the details, refer to the latest GTWIN HELP.
  • Page 99  SD memory card Item Specifications SD memory card, SDHC memory card Support media (Note 1) (The manufacturer that the operation check has done: Panasonic Corporation) Conforms to SD standard Supported format standard (Please format with format software for SD memory cards.) (Note 1): Check the usable temperature range of a SD memory card to be used before use.
  • Page 100: Dimensions

    Specifications 6.3 Dimensions 6.3.1 GT703 Main Unit  Dimensions (Unit: mm)  Panel cutout dimensions (Unit: mm) Applicable panel thickness 1.0 mm to 5.0 mm 6-12...
  • Page 101: Gt704 Main Unit

    6.3 Dimensions 6.3.2 GT704 Main Unit  Dimensions (Unit: mm)  Panel cutout dimensions (Unit: mm) Applicable panel thickness 1.0 mm to 5.0 mm 6-13...
  • Page 102: Cable Specifications

    Specifications 6.4 Cable Specifications 6.4.1 AIGT8160 / AIGT8162 / AIGT8165 6.4.2 AIGT8175 6.4.3 AIP81842 6-14...
  • Page 103 Record of changes Manual No. Date Record of Changes WUME-GT703H-01 Jul.2017 1st Edition...
  • Page 105 ■ Overseas Sales Division (Head Office): 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan ■ Telephone: +81-568-33-7861 ■ Facsimile: +81-568-33-8591 panasonic.net/id/pidsx/global For our sale network, please visit our website. © Panasonic Industrial Devices SUNX Co., Ltd. 2017 Jul. 2017 PRINTED IN JAPAN WUME-GT703H-01...

This manual is also suitable for:

Gt704Gt seriesGt704mGt703m

Table of Contents