32-channel, 24 v sourcing digital output module

Advertisement

Quick Links

sales@artisantg.com
artisantg.com
(217) 352-9330 |
|
Click HERE
Find the National Instruments sbRIO-9476 at our website:

Advertisement

Table of Contents
loading

Summary of Contents for National Instruments 9476E

  • Page 1 (217) 352-9330 | Click HERE Find the National Instruments sbRIO-9476 at our website:...
  • Page 2 OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E 32-Channel, 24 V Sourcing Digital Output Module Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 3 This document describes how to use the National Instruments 9476E and includes dimensions, connector assignments, and specifications for the NI 9476E. Visit and enter ni.com/info rdsoftwareversion to determine which software you need for the modules you are using. For information about installing, configuring, and programming the system, refer to the system documentation.
  • Page 4 The following figure shows the dimensions of the NI 9476E. Figure 1. NI 9476E Dimensions in Millimeters (Inches) 73.4 (2.89) 0.0 (0.00) NI 9476E Operating Instructions and Specifications | © National Instruments | 3 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 5: Connecting The Ni 9476E

    Connecting the NI 9476E The NI 9476E has a 37-pin DSUB connector that provides connections for 32 digital output channels. Figure 2. NI 9476E Pin Assignments DO16 DO17 DO18 DO19 DO20 DO21 DO22 DO23 Vsup Vsup Vsup Vsup DO24 DO25...
  • Page 6 The NI 9476 has current sourcing outputs, meaning the DO pin is driven to V when the channel is turned on. NI 9476E Operating Instructions and Specifications | © National Instruments | 5 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 7 To ensure a grounded connection, use shielded Caution I/O cables and tie the shield to the chassis ground. 6 | ni.com | NI 9476E Operating Instructions and Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 8: Increasing Current Drive

    Figure 4. Increasing the Current to a Device Connected to the NI 9476 250 mA External Power 250 mA Supply Device 250 mA 250 mA NI 9476 NI 9476E Operating Instructions and Specifications | © National Instruments | 7 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 9: Protecting The Module From Flyback Voltages

    Figure 5. Connecting a Flyback Diode to the NI 9476 External Power Supply Flyback Inductive Diode Device NI 9476 8 | ni.com | NI 9476E Operating Instructions and Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 10: Understanding Protected Devices

    Refer to the software help for information about reading output status. NI 9476E Operating Instructions and Specifications | © National Instruments | 9 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 11: Sleep Mode

    Refer to the Specifications section for more information about power consumption and thermal dissipation. 10 | ni.com | NI 9476E Operating Instructions and Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 12: Specifications

    With 30 to 36 VDC supply voltage ......200 mA max Output impedance (R ) ..... 0.3 Ω max NI 9476E Operating Instructions and Specifications | © National Instruments | 11 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 13 ....28 mA max Maximum update rate ....... 40 μs max Propagation delay ......500 μs max 12 | ni.com | NI 9476E Operating Instructions and Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 14: Power Requirements

    If you need to clean the module, wipe it with a dry towel. Weight..........46 g (1.6 oz) NI 9476E Operating Instructions and Specifications | © National Instruments | 13 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 15: Maximum Voltage

    The maximum voltage that can be applied or output between V and COM without creating a safety hazard. 14 | ni.com | NI 9476E Operating Instructions and Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 16 5,000 m altitude ..500 V , verified by a 5 s dielectric withstand test NI 9476E Operating Instructions and Specifications | © National Instruments | 15 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 17: Safety Standards

    , search by module number or product line, and certification click the appropriate link in the Certification column. 16 | ni.com | NI 9476E Operating Instructions and Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 18: Shock And Vibration

    PCB, 0.2 in. (5 mm) from the board surface. Avoid placing thermocouples next NI 9476E Operating Instructions and Specifications | © National Instruments | 17 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 19: Environmental Management

    NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. 18 | ni.com | NI 9476E Operating Instructions and Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 20: Waste Electrical And Electronic Equipment (Weee)

    (RoHS) National Instruments RoHS (For information ni.com/environment/rohs_china about China RoHS compliance, go to ni.com/ environment/rohs_china NI 9476E Operating Instructions and Specifications | © National Instruments | 19 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 21: Worldwide Support And Services

    . If your product supports calibration, ni.com/certification you can obtain the calibration certificate for your product ni.com/calibration 20 | ni.com | NI 9476E Operating Instructions and Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 22 For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents . You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product.

This manual is also suitable for:

Sbrio-9476

Table of Contents