Electrical Connection - Miele KF 2802 Vi Operating And Installation Instructions

Table of Contents

Advertisement

Installation

Electrical connection

The refrigeration appliance must only be
connected to an earthed socket using
the mains connection cable supplied.
The socket must be easily accessible
after the refrigeration appliance has
been installed. If the socket is not easily
accessible, ensure that a suitable
means of disconnection is provided on
the installation side for each pole.
Risk of fire from overheating.
Connecting the refrigeration
appliance to a multi-socket plug
adapter or to an extension lead can
overload the cable.
For safety reasons, do not use an
extension lead or multi-socket
adapter.
The electrical installation must comply
with VDE 0100 requirements.
For safety reasons, we recommend
using a type  residual current device
(RCD) in the assigned electrical
installation for connecting the
refrigeration appliance.
If the mains connection cable is
damaged, it must only be replaced with
a specific mains connection cable of the
same type (available from the Miele
Customer Service Department). For
safety reasons, such replacement may
only be carried out by a qualified
specialist or the Miele Customer
Service Department.
These operating instructions and the
data plate indicate the nominal power
consumption and the appropriate fuse
rating. Compare this information with
the data of the on-site electrical
connection. If in any doubt, consult a
qualified electrician.
50
Temporary or permanent operation on
an autonomous power supply system or
a power supply system that is not
synchronised with the mains power
supply (e.g. island networks, back-up
systems) is possible. A prerequisite for
operation is that the power supply
system complies with the specifications
of EN 50160 or an equivalent standard.
The function and operation of the
protective measures provided in the
domestic electrical installation and in
this Miele product must also be
maintained in isolated operation or in
operation that is not synchronised with
the mains power supply, or these
measures must be replaced by
equivalent measures in the installation.
As described, for example, in the current
version of VDE-AR-E 2510-2.

Advertisement