Download Print this page
Rinnai RX Series Conversion Manual
Rinnai RX Series Conversion Manual

Rinnai RX Series Conversion Manual

Gas conversion
Hide thumbs Also See for RX Series:

Advertisement

Available languages

Available languages

Quick Links

Advertisement

loading
Need help?

Need help?

Do you have a question about the RX Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Rinnai RX Series

  • Page 2 This conversion kit shall be installed by a qualified service WARNING agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. The information in these instructions must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death.
  • Page 3 For installations in Canada, the conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in accordance with the requirements of the CSA-B149.1, Natural Gas and Propane Installation Code. Para instalaciones en Canadá, la conversión se efectuará de acuerdo con los requisitos de las autoridades provinciales competentes y de acuerdo con los requisitos del Código de Instalación de Gas Natural y Propano, CSA B149.1.
  • Page 4 IMPORTANT The Spanish manual continues on page 11. (El manual en español continúa en la página 11.) Model RX199i RX180i RX160i RX130i RXP199i RXP160i CX199i CX160i CXP199i CXP160i Minimum 15,000 Gas Consumption (Btu/h) Maximum 199,000 180,000 160,000 130,000 Minimum: 3.5 in. (0.87 kPa) W.C. Natural Gas Maximum: 10.5 in.
  • Page 5 “Bluetooth” integrated controller. button 5. Tap “Connect to a Rinnai Tankless Water Heater” on the Rinnai Central app (Figure 2). You will hear a beeping sound when pairing between the app and water heater is Note: To utilize BLE, your connecting device established.
  • Page 6 9. Proceed to the next section to continue the gas conversion steps. Notice: You may see error code 21 at this point. If so, contact Rinnai at 1-800-621-9419. Gas Conversion Manual for Condensing Tankless Water Heaters...
  • Page 7: For Your Safety Read Before Operating

    The following operating information is required by ANSI Z21.10.3. FOR YOUR SAFETY READ BEFORE OPERATING If you do not follow these instructions exactly, a fire or WARNING explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. •...
  • Page 8 Follow the section “For Your Safety Read Before Operating” in section “4.2 WARNING Gas Operating Instructions” before starting the steps below. IMPORTANT • Confirm that the inlet gas pressure is between the minimum and maximum pressures allowed for this water heater. •...
  • Page 9 3. Press the “On/Off” button on the controller to start Figure 6 the unit (Figure 6). Set the water temperature to 120°F (49°C) or higher, and turn on two or three faucets or showers. Refer to the “Tankless Water Heater Installation and Operation Manual”...
  • Page 10 1. Remove the water heater front panel (if not done so already) by removing the two screws and releasing the two latches. Refer to the “Tankless Water Heater Installation and Operation Manual” for complete instructions on removing the front panel. 2.
  • Page 11 IMPORTANT The Spanish manual continues below. (El manual en español continúa a continuación.) Modelo RX199i RX180i RX160i RX130i RXP199i RXP160i CX199i CX160i CXP199i CXP160i Mínimo 15 000 Consumo de gas (BTU/h) Máximo 199 000 180 000 160 000 130 000 Mínima: 3.5 pulg.
  • Page 12 Botón 'Bluetooth' Toque 'Conectar a un calentador de agua sin tanque Nota: Para utilizar Bluetooth de baja energía Rinnai' en la aplicación Rinnai Central (Figura 2). (Bluetooth Low Energy, BLE), su dispositivo de conexión (teléfono inteligente, tableta, computadora, Cuando se establezca el emparejamiento entre la etc.) debe tener Bluetooth 4.0 o una versión más...
  • Page 13 Pase a la sección siguiente para continuar los pasos de la conversión de gas. Aviso: Es posible que vea el código de error 21 en este momento. Si es así, comuníquese con Rinnai al 1 -800-621-9419. Manual de conversión de gas para calentadores de agua sin tanque con condensación...
  • Page 14: Instrucciones De Operación

    ANSI Z21.10.3 requiere la siguiente información operativa. PARA SU SEGURIDAD, LEA ANTES DE MANEJAR EL ARTEFACTO Si no sigue estas instrucciones al pie de la letra, puede ADVERTENCIA producirse un incendio o una explosión, con la posibilidad de causar daños materiales, lesiones personales o la pérdida de la vida.
  • Page 15 Para ver las instrucciones completas de extracción del panel frontal, consulte el 'Manual de instalación y operación del calentador de agua sin tanque Rinnai'. 2. Retire la tapa de caucho, como se muestra en la Figura 5, e inserte en la abertura una sonda analizadora de gas (a suministrar en el sitio).
  • Page 16 Para conocer los pasos del ajuste de la temperatura del agua, consulte el 'Manual de instalación y operación del calentador de Botón agua sin tanque Rinnai' 'Encendido/ Apagado' El ventilador de combustión comenzará a funcionar si ('ON/OFF') hay circulación de agua, y la chispa encenderá...
  • Page 17 Si no lo ha hecho ya, extraiga el panel frontal del calentador de agua quitando los dos tornillos y liberando los dos cierres. Para ver las instrucciones completas de extracción del panel frontal, consulte el 'Manual de instalación y operación del calentador de agua sin tanque Rinnai'. Pulse el botón 'Encendido/Apagado' ('ON/OFF') del Figura 10 controlador para poner en marcha la unidad (Figura 10).
  • Page 18 Gas Conversion Manual for Condensing Tankless Water Heaters...
  • Page 19 Gas Conversion Manual for Condensing Tankless Water Heaters...