Force Control; Contact Reverse Test; Contact Reverse Adjustment - Overhead door 1029 Operation & Maintenance Manual

Table of Contents

Advertisement

Wall Control Operation

Force Control

The force controls are automatically set when the wall control is used
for the first time with garage door opener. The door MUST complete
one full cycle, from full open to full close and then, full close to full
open, before the settings are automatically recorded.
10. Press and release the wall console Open/Close button
and allow the garage door to travel and stop at the
down (closed) limit.
or
or
11. Press and release the wall console Open/Close button
and allow the garage door to travel and stop at the Up
(open) limit.
or
NOTE: Force controls DO NOT require programming. Force limits are factory
set and rarely require adjustments. Making adjustments to these settings is
covered in the "Maintenance and Adjustments" Section of this Manual (pages
14-18). FORCE CONTROL IS NOW SET.
WARNING
!
TO AVOID INJURY OR DAMAGE
NEVER adjust the force settings to adjust for damage,
including an unbalanced door, binding door track or
broken spring.
Perform a CONTACT REVERSE TEST monthly. See page 8.
AVERTISSEMENT
!
Pour éviter les blessures ou des dommages
NE JAMAIS régler la force pour compenser des dommages,
y compris une porte mal équilibrée, un rail de porte coinçant
ou des ressorts cassés.
Tous les mois, EFFECTUEZ LE TEST D'INVERSION AU CONTACT.
Voir page 8.
8
or

Contact Reverse Test

NOTE: The limit and Force settings MUST BE COMPLETED before
performing the Contact Reverse Test.
12. With the garage door open, lay a 2" x 4" board flat on
the floor at the center of the door opening.
13. Close the garage door using the Open/Close button on
the wall control.
or
or
When the door contacts the board, it should stop and reverse
direction within 2 seconds to the fully open position. Red LED
lights on the powerhead will begin to flash with the reversal of
the door. Remove the 2" x 4" board after a successful contact
reversal test. The next cycle will clear the flashing red LEDs.

Contact Reverse Adjustment

If the door stops before contacting the board or if it does not
reverse direction to fully open after contact with the board, it
may be due to an improperly set DOWN limit. Verify settings by:
1. Repeat the "Down Travel Limit" section (page 6) to make
certain the door is closing tight against the floor.
2. Repeat the "Force Control" section on the left to set force
limits.
3. Repeat the "Contact Reverse Test" above.
Repeat this process as needed until the door passes the Contact
Reverse Test. For further help, refer to the "Maintenance and
Adjustment" section/Regular Maintenance. Pages 14-18.