The ULTRA CLEAN program terminate with an extra anti-bacteria rinse that ensures a
further reduction in the bacteria level. If the temperature falls during this stage of the
program (e.g. because the door is opened or due to a power blackout), the program lights
(2) flash to warn that the anti-bacteria effect is not guaranteed.
If an alarm occurs the appliance interrupts the program in progress and
signals a fault.
Alarms E1, E2, E3, E4, E8 and E9 interrupt the current program
immediately.
The E5, E6 alarms interrupts the running program once the cause is
resolved, it will bring bach the execution of the program.
The alarm E7 is visualized at the end of the cycle that comes, however,
brought to the end since the operation of the dishwasher is not harmed.
To "reset" an alarm is necessary:
Open and close the door, or turn off and on the machine. At this point is
possible to program the dishwasher again.
If the malfunction persists, contact your authorised Service Centre.
TECHNICAL DATA
Width
Depth measured flush with the
outer edge of the control panel
Height
Capacity
Water supply pressure
Electrical characteristics
30
User instructions
447 ÷ 449 mm
550 mm
from 820 mm to 890 mm
10 Standard place settings
min. 0,05 - max. 0,9 MPa (min. 0.5 – max. 9 bar)
See rating plate