Radio Shack PRO-2050 Service Manual page 9

Vhf/uhf/airl800mhz 300-channel trunktracker home scanner
Hide thumbs Also See for PRO-2050:
Table of Contents

Advertisement

ALlGNMENT OF NFM DISCRIMINATOR
Test Equipment Required and Connections
SG
Digital Voltmeter
I~I
Set
D
~ ~---Á
~ANT
~
To LND6
.n
",",' Jack
~
\L ___ V
~
J5D1
-0
,J;
De Power Supply
I'/"IJ'/"I
o
9
I
To Power Jack J2
12V
Alignment Procedure
Step
Presetto
Adjustment
Result
CH2
1
SG: 40.84 MHz
L12
Conneet the digital voltmeter to LND6. (See Page 15 tor
No modulation
the position.) Adjust L12 to obtain 1.3 V ±0.05 VOC.
100 !-tV
Alignment Point Locations (RF PCB)
- 9 -
o
L12