Item
Unit
Nominal
Limit
Sensitivity (S+N)/N=20 dB
VHF low band
40.840 MHz
f.lV
0.5
2.0
VHF high band
162.400 MHz
f.lV
0.5
3.0
UHF band
453.250 MHz
f.lV
0.4
3.0
Aircraft band
127.175 MHz
f.lV
1.5
8.0
Public service band
857.200 MHz
f.lV
0.7
4.0
Maximum sensitivity
127.175 MHz
f.lV
0.2
2.0
Threshold squelch (MANUAL)
VHF low band
at 40.840 MHz
f.lV
0.4
0.8
VHF high band
at 162.400 MHz
f.lV
0.5
1.2
UHF band
at 453.250 MHz
f.lV
0.4
1.8
Aircraft band
at 127.175 MHz
f.lV
0.6
2.0
Public service band
at 857.200 MHz
f.lV
0.3
3.0
Tight squelch (MANUAL) (S+N)/N
VHF low band
at 40.840 MHz
dB
25
15
VHF high band
at 162.400 MHz
dB
25
15
UHF band
at 453.250 MHz
dB
25
15
Aircraft band
at 127.175 MHz
dB
15
1"0
Public service band
at 857.200 MHz
dB
25
15
Hum and noise
VHF low band
at 40.840 MHz
dB
39
30
VHF high band
at 162.400 MHz
dB
39
30
UHF band
at 453.250 MHz
dB
39
30
Aircraft band
at 127.175 MHz
dB
50
30
Public service band
at 857.200 MHz
dB
39
30
Data deviation sensitivity
Control ch data
at 851.0125 MHz
kHz
±0.3
±1.5
Voice ch data
at 851.0125 MHz
kHz
±0.1
±10
Audio frequency response -6 dB
(at 162.400 MHz)
Low
Hz
300
200 - 450
High
Hz
2300
1300 - 3000
(at 127.175 MHz)
Low
Hz
280
200 - 450
High
Hz
2200
1300 - 3000
Audio output power of internal speaker
(at 162.400 MHz)
Maximum
mW
1100
700
1Q%THD
mW
1000
600
(at 127.175 MHz)
Maximum
mW
1100
700
10% THD
mW
1000
600
(at 162.4 MHz 32
Q
EAR.)
Maximum
V
0.8
0.5