Radio Shack PRO-2050 Service Manual page 10

Vhf/uhf/airl800mhz 300-channel trunktracker home scanner
Hide thumbs Also See for PRO-2050:
Table of Contents

Advertisement

ALlGNMENT OF SQUELCH
Test Equipment Required and Connections
SG
Oscilloscope
o
o
D
Digital Voltmeter
EXT.EAR
Jack J1
+ -
Set
ANT
(
rn--+--++--+l----+-+l~)
Jack
J501
De Power Supply
Alignment Procedure
To Power Jack J2
12V
l'
0.1 llF
Step
Preset
to
Adjustment
Result
CH2
Set the SG level so that the voltage at LND7 is 0.96 ±0.05
1
SG: 40.840 MHz
No modulation
V DC. (See Page 15 for the position.)
CH2
SG: 40.840 MHz
2
1KHz±3KHz
RT1
Adjust RT1 slowly until the squelch opens
Dev
Squelch: CW
Alignment Point Location (RF PCB)
ANT Jack
D
J501
Power Jack
J2
D
EXT.EAR
Jack J1
0
el
RT1
-10-