PROJECTION CONFIGURATION CHANGE

Scan Reversal

You will have to reverse the horizontal polarity when changing the projector's configuration.
NOTE: For vertical polarity , scan reversal can be changed using the PROJECTION feature in the SETTING MODE menu.
To reverse the scan, proceed as follows:
CAUTION: Always disconnect the projector from the AC source before reversing the plug. Failure to observe this precaution may
result in electric shock or damage to the projector.
1 Remove the top cover.
• See Removing and reinstalling Top Cover section.
2 Reverse the horizontal scan.
• To reverse the scan there are three plugs on the sweep board. EB, EG and ER are the horizontal connectors.
First remove the dummy plug.
Secondly remove the plug and turn it 180 degrees, then reinstall. Do this for all three of horizontal connectors depending upon
your application (See Table below). Third, install the dummy plug on the opposite side.
Horizontal polarity
Desk top, front / Ceiling, rear
EB
EG
ER
Desk top, rear / Ceiling, front
Red
Blue
Dummy
plug
EB
EG
Red
14
Dummy
plug
Blue
Red
ER
Blue