Maintenance; Compliance To Fcc Rules - Genelec 1237A Operating Manual

Smart active monitors
Hide thumbs Also See for 1237A:
Table of Contents

Advertisement

HEAVY WOODEN WALL
ABSORBING
MATERIAL
AMPLIFIER
REMOVED
FROM ENCLOSURE
VIBRATION
ISOLATORS
f ~ 2-8 Hz
Figure 11. Flush mounting the moni-
torin a wall constructed of wood
Button press
Short press
Long press
Special mode: one short press
Short press advances
Short press advances
Short press advances
Special selection: long press
Special mode: no press for 60
seconds
Table 2. Power button actions to activate testing modes
necessary to maintain sufficient cool-
ing. Do not obstruct airflow around the
monitors.
WARNING!
The Genelec 1237A and 1238A monitors are
capable of producing sound pressure levels
in excess of 85 dB, which may cause perma-
nent hearing damage.
CONCRETE WALL
SAND
BAGS
AMPLIFIER
REMOVED
FROM ENCLOSURE
VIBRATION
ISOLATORS
f ~ 2-8 Hz
Figure 12. Flush mounting the monitor
in a wall constructed of concrete
Function
Power on, power off
Enter special mode, exit special
mode
Mode 1: AES/EBU channel A
selected, room-related calibra-
tion in use
Mode 2: AES/EBU channel B
selected, room-related calibra-
tion in use
Mode 3: AES/EBU channel A
selected, factory calibration
in use
Mode 4: AES/EBU channel B
selected, factory calibration
in use
Once a special mode 1-4 has
been selected, a long press
selects the special mode
RAM-L exits the special mode
and turns off

Maintenance

No user serviceable parts are to be found
within the monitor enclosure or the RAM-L
amplifier unit. Any maintenance or repair of
the monitor should only be undertaken by
qualified service personnel.
Notes
Press longer than 5 seconds
Power button light blinks once
every few seconds
Power button light blinks twice
every few seconds
Power button light blinks three
times every few seconds
Power button blinks four times
every few seconds
Press longer than 5 seconds;
the RAM-L selects the special
mode and starts playing. To exit
the special mode turn off the
amplifier.
Automatically happens if user
does not press the power
button
MULTI-LAYERED WALL
(WOOD, CONCRETE,
BRICKS)
AMPLIFIER
REMOVED
FROM
ENCLOSURE
CONCRETE
STRUCTURE
VIBRATION
ISOLATORS
f ~ 2-8 Hz
Figure 13. Flush mounting the monitor
in a wall constructed of a combination
of materials.
SPEAKER
RUBBER GASKET
(5-10 mm / ¼-½")
FACING PANEL
FIXED TO THE WALL
(50-100 mm / 2-4")
WALL
Figure 14. Covering the gap between
the wall and the monitor cabinet.
Guarantee
Genelec 1237A and 1238A are supplied with
a two year guarantee against manufacturing
faults or defects that might alter the perfor-
mance of the monitors. Refer to supplier for
full sales and guarantee terms.
Accessories
A wide selection of accessories is available
for Genelec monitors. Consult the Acces-
sories Catalogue on www.genelec.com or
your local distributor/dealer for up-to-date
information.

Compliance to FCC Rules

This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions:
1.
This device may not cause harmful interfer-
ence
2.
This device must accept any interference
received, including interference that may
cause undesired operation.

Advertisement

Table of Contents
loading

This manual is also suitable for:

1238a

Table of Contents