13. Power Input Socket: Connect the supply plug to the
existing input cable, that is rated for the machine as
indicated in this manual, and conforms to all
applicable standards.
performed only by a qualified person.
14. Hole covered: For 48Vac socket.
15. Hole covered: For circuit breaker which protects the
48Vac socket .
16. Fuse: This fuse protects the Fan Circuit.
Stick Welding (MMA)
For starting welding process with MMA method you
should:
Insert welding cable plugs into output sockets and
twist to lock them in place.
Connect the work cable to the welding piece with the
work clamp.
Fasten a correct coated electrode into the electrode
holder.
Connect the main plug to the outlet mains socket.
Set the Local/Remote Switch in required position:
local or remote.
Turn the Power on/off Switch on.
Set required welding current by knob of the Output
Current Control.
Obeying appropriate rules you can begin to weld.
English
This connection shall be
Maintenance
For any maintenance or repair operations it is
recommended to contact the nearest technical service
center or Lincoln Electric.
performed by unauthorized service centers or personnel
will null and void the manufacturers warranty.
The frequency of the minatenance operations may vary
in accordance with the working environment where the
machine is placed.
Any noticeable damage should be reported immediately.
Routine maintenance (everyday)
Check cables and connections integrity. Replace, if
necessary.
Check condition and operation of the cooling fan.
Keep clean its airflow slots.
Periodic maintenance (every 200 working hours but
not more rarely than once a year)
Perform the routine maintenance and, in addition:
Keep clean the machine.
pressure) airflow, remove the dust from the external
case and from inside of the cabinet.
Check and tighten all screws.
Mains supply network must be disconnected from the
machine before each maintenance and service. After
each repair, perform proper tests to ensure safety.