DIAGNOSTIC GUIDES
OPERATION LAMP
TIMER LAMP
☆ 1 time
☆ 2 times
☆ 4 times
☆ 5 times
☆ 6 times
☆ 7 times
☆ 8 times
☆ 1 time
☆ 2 times
☆ 3 times
☆ 4 times
☆ 5 times
☆ 6 times
☆ 7 times
☆ 8 times
☆ 9 times
☆ 10 times
☆ 1 time
☆ 2 times
☆ 3 times
☆ 4 times
☆ 5 times
☆ 6 times
☆ 7 times
☆ 8 times
Table 14—Diagnostic Guides Indoor Units
DISPLAY
X
E0
Indoor unit EEPROM parameter error
X
E1
Communication malfunction between indoor and outdoor units
X
E3
Indoor fan speed malfunction
X
E4
Indoor room temperature sensor (T1 ) malfunction
X
E5
Evaporator coil temperature sensor (T2) malfunction
X
EC
Refrigerant leakage detection
X
EE
Water-level alarm malfunction
O
F0
Current overload protection
O
F1
Outdoor ambient temperature sensor (T4 ) malfunction
O
F2
Condenser coil temperature sensor (T3) malfunction
O
F3
Compressor discharge temperature sensor (T5) malfunction
O
F4
Outdoor unit EEPROM parameter error
O
F5
Outdoor fan speed malfunction
O
F6
Indoor coil outlet pipe sensor(Located on outdoor unit low pressure valve)
O
F7
Communication malfunction between the cassette optional lift panel and the unit
O
F8
Cassette optional lift panel malfunction
O
F9
Cassette optional lift panel not closed
P0
Inverter module (IPM) malfunction
P1
Over-voltage or under-voltage protection
P2
Compressor top high temperature protection (OLP)
P3
Low ambient temperature cut off in heating
P4
Compressor drive malfunction
P5
Indoor units mode conflict
P6
Low pressure protection
P7
Outdoor IPM temperature sensor error
O(light)
LED STATUS
☆(flash)
X(off)