Storage upon power failure
• In case of power failure, the instant working state will be locked and maintained till
Error code
• The following warnings appearing on the display indicate corresponding faults of
the refrigerator. Though the refrigerator may still have cold storage function with
the following faults, the user shall contact a maintenance specialist for maintenance,
so as to ensure optimized operation of the appliance.
Error code
E1
Temperature sensor failure of refrigerating chamber
E2
Temperature sensor failure of freezing chamber
E5
Freezing defrost sensor detection circuit error
E6
Communication error
E7
Circulation of temperature detection circuit error
Out of operation
• Power failure: In case of power failure, even if it is in summer, foods inside the
appliance can be kept for several hours; during the power failure, the times of door
opening shall be reduced, and no more fresh food shall be put into the appliance.
• Long-time nonuse: The appliance shall be unplugged and then cleaned; then the
doors are left open to prevent odor.
partitions, vegetable holder, freezing chamber drawers and etc. with tape, and
the appliance shall not be laid upside down or horizontally, or be vibrated; the
inclination during movement shall be no more than 45°.
ATTENTION
The appliance shall run continuously once it is started. Generally, the operation of the
appliance shall not be interrupted; otherwise the service life may be impaired.