 Model: AOEH14KHCBN
Fan speed is defined by outdoor temperature and rotation number of compressor.
• Outside air temperature zone selection
Cooling
Fan step
Y zone
S-HIGH2
S-HIGH1
1,290
HIGH
1,290
10
9
1,290
8
1,150
7
1,000
6
5
4
3
2
1
NOTE: After defrost control on the heating mode, the fan speed is kept higher regardless of the
compressor frequency.
Fan speed after defrost control: 1,200 rpm
3-2. Outdoor fan control
Outside air
temperature rises
21°C
12°C
2°C
-8°C
Heating
Y zone
1,200
1,200
1,200
1,200
1,170
990
830
880
800
760
740
640
640
550
460
460
420
460
380
Outside air
temperature drops
Y zone
Z zone
F zone
G zone
H zone
Dry
Cooling or dry at low outdoor temp.
Z zone
1,290
440
1,150
440
1,000
440
880
350
760
260
640
260
550
260
460
260
460
260
- (04-16) -
19°C
10°C
0°C
-10°C
F zone
G zone
270
220
270
220
270
220
230
200
200
200
200
200
200
200
200
200
200
200
Unit: rpm
H zone
220
220
220
200
200
200
200
200
200