1-5. Limitation of compressor rotation number by outdoor temperature
F zone
19°C
E zone
5°C
D zone
0°C
C zone
-15°C
B zone
-25°C
A zone
Outdoor temperature zone
A zone
B zone
C zone
D zone
E zone
F zone
A zone
B zone
C zone
D zone
E zone
F zone
- (04-7) -
Unit: rps
Limitation of compressor
rotation number
60
39
20
14
1
1
60
31
20
14
1
1