Installation instructions for kit number 9021870
Kit installation must be performed by TennantTrue
SYNOPSIS:
This kit contains the parts needed to assemble a manifold assembly for:
M20 sweeper scrubbers (NA serial numbers 014001-
M30 sweeper scrubbers (NA/CE serial Numbers 010001-
T20 scrubbers (NA serial numbers 013001-
Please follow step-by-step instructions.
SPECIAL TOOLS/CONSIDERATIONS: NONE
(Estimated time to complete: 30 minutes)
PREPARATION:
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off
machine, set parking brake, and remove key.
NOTE: Refer to applicable kit/IB for locations of
additional fittings installed onto the solution
manifold (2).
INSTALLATION:
1. Thread a plug fitting (8) into the solution
manifold (2) ports not to be used for the
applicable kit installation. Refer to the
applicable kit/IB for port(s) to be left open.
(Fig. 1)
NOTE: Only install plug(s) (8) into solution
manifold (2) port(s) not used for installation of
applicable kit. Refer to kit/IB for ports to be left
open. (Fig. 1)
IB 9021896 (01- 2024)
PROTECT THE ENVIRONMENT
Please dispose of packaging materials, used machine components
such as batteries and fluids in an environmentally safe way according
to local waste disposal regulations.
Always remember to recycle.
service or an authorized service provider.
) (CE serial numbers UO1500-
)
) (CE serial numbers UO1400-
2. Thread the plastic elbow fitting (12) into the
solution manifold (2). (Fig. 1)
3. Thread the plastic straight fitting (7) into the
solution manifold (2) MAIN port. (Fig. 1)
4. Use a hose clamp (10) to connect the 1.8 in.
(46 mm) PVC hose (9) to the plastic straight
fitting (7) in the solution manifold (2) MAIN
port. (Fig. 1)
5. Use a hose clamp (10) to install the water
solenoid valve (1) onto the 1.8 in. (46 mm)
PVC hose (9) installed at the solution manifold
(2) MAIN port. (Fig. 1)
6. Thread a plastic straight fitting into the
applicable solution manifold (2) port for the kit
being installed. Refer to the kit/IB for the port
requiring a plastic straight fitting. (Fig. 1)
No. 9021896
Machine: M20/T20/M30
Published: 01- 2024
Rev. 00
)
).
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the 9021870 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tennant 9021870

  • Page 1 NOTE: Numbers in parenthesis ( ) are reference numbers for parts listed in Bill of Materials. Installation instructions for kit number 9021870  Kit installation must be performed by TennantTrue service or an authorized service provider.
  • Page 2 7. Use a hose clamp to connect the 1.8 in. 8. Use a hose clamp to install a water solenoid (46 mm) PVC hose to the plastic straight valve onto the 1.8 in. (46 mm) PVC hose fitting installed in the previous step. (Fig. 1) installed in the previous step.
  • Page 3 Bill Of Materials For Parts Phantom, Manifold, Aftmkt - 9021870 Tennant Part No. Ref. Description Qty. 1076870 Valve, Water, Solenoid [12vdc, BM08/BM08] 1254833 Manifold, Soln 1254856 Plate, Manifold, Mtg 32490 Washer, Flat, 0.25, Std 1257800 Screw, Hex, M6 X 1.00 X 60, SS, Fl 08712 Nut, Hex, Lock, M6 X 1.00, NL, SS...