13. INSTALLER MENU

The Installer menu shows the options to control external
devices like pumps, valves, and auxiliaries, directly from
the heat pump built-in scheduler or Online Raymote
automation.
"Installer Menu" can be accessed from the program
menu. Use the UP key to enter in the Installers menu or
press SERVICE to skip to the next option.
• Use the SERVICE key to move along the options of
the Installer menu.
• Use the UP and DOWN keys in each screen to adjust
and select operation modes and settings.
• Use MODE key to return to the "Program Menu".
Auxiliary Output 1 & 2 Operation
Modes
When entering the INSTALLER menus, the displays
will show "Auxiliary 1 mode" and "Auxiliary 2 mode." On
each screen, you can choose an operation mode using
the UP and DOWN keys. These modes include:
• Raymote: which allows Wi-Fi control using Raymote
online automation.
• Schedule: which allows the heat pump built-in clock
and schedule to control the auxiliary.
• Auxiliary Heat: which configures the auxiliary to
turn on an external heater. The control will turn on the
auxiliary automatically if the water temperature is 10°F
lower than the pool or spa heat setpoint. The unit will
turn off the auxiliary when heat demand is satisfied.
The default value for the 'Auxiliary 1' and 'Auxiliary 2'
operation modes is the Raymote mode.
For details regarding auxiliary wiring, refer to section 27,
"Optional Control Outputs", on page 72.
Auxiliary 1 mode
Auxiliary 2 mode
Figure 40. Auxiliary Output Operation Modes
Single-Speed Pump Operation Mode
To access the "Single-Speed Pump" operation mode,
press the SERVICE key again, and the digital display
will show "Single-Speed Pump." To select an operation
mode, use the UP and DOWN keys and choose from the
following options:
Raymote
Raymote
• Raymote: The single-speed pump output is set to be
controlled from Wi-Fi with Raymote online automation.
• Schedule: The single-speed pump output is set
to be controlled by the heat pump built-in clock and
schedule.
• Heater Demand: The single-speed pump output
is set to turn on when the heater starts the heating
or cooling operation. The unit turns the single-speed
pump output off when heat demand is satisfied.
The default value for single-speed pump output operation
mode is "Disabled". This function can be used with the
control board terminal P5 labeled as "PUMP." For details
about single-speed pump wiring, refer to section 27,
"Optional Control Outputs", on page 72.
Single Speed Pump
Single Speed Pump
Figure 41. Single-Speed Pump Operation Mode
Variable-Speed Pump Operation Mode
When you press the SERVICE key again, the digital
display will show "VS Pump Control." To select an
operation mode, use the UP and DOWN keys and choose
from the following options:
• Disabled: The Variable-Speed Pump functions are
disabled, and no commands are sent to the external
pump.
• Protégé VSP: The heater uses a 4-pin terminal P12
labeled as "COM" to command an external Raypak
Protégé Variable-Speed Pump.
• 4-Speed Control: The heater's 4-speed control is
achieved by using the 5-pin digital outputs located in
the terminal P8 labeled "VAR PUMP" to command an
external variable-speed pump that is compatible with
30V DC signals supplied by the heater.
By default, the variable-speed pump output operation
mode is set to "Disabled". For more information about the
wiring of the variable-speed pump, refer to section 27,
"Optional Control Outputs", on page 72.
VS Pump Control
4-Speed Control
VSP Control Mode
Heater Demand
Pump Heat Speed
Figure 42. Variable-Speed Pump Operation Mode
Raymote
Disabled
3
21