Daikin Rotex GW-20 C28 Installation Instructions Manual page 27

Hide thumbs Also See for Rotex GW-20 C28:
Table of Contents

Advertisement

Assembly of combi extension pipe for balcony/gallery outlet
If free output is hindered by a roof overhang, balcony, gallery etc., the combi
feedthrough pipe must be extended until at least the front of the overhanging part.
1.
Fit the combi extension pipe onto the combi feedthrough.
2.
Shorten the combi feedthrough or the combi extension pipe to the correct
length in accordance with the measurements provided.
3.
Fit the exhaust roster and attach it to the inner pipe.
4.
Fit the combi feedthrough and combi extension pipe on a slope towards the
unit.
Assembly of horizontal roof terminal
5.
The outlet can be made on any place on the roof surface.
6.
Fit a horizontal feed-through roof panel (D) (suitable for a ø120 mm pipe) at
the location of the outlet.
7.
Fit the exhaust roster onto the combi feedthrough and attach it to the inner
pipe.
8.
Slide the combi feedthrough (C) from inside to outside through the horizontal
roof feed-through panel, in accordance with the given measurements.
9.
Fit the combi feedthrough (C) on a slope towards the unit.
ROTEX Heating Systems GmbH
27

Advertisement

Table of Contents
loading

Table of Contents