Transporting with eye bolt
Transporting with
lifting strap
6.1.2

Transporting with a lifting device

For transporting, the axial piston unit can be connected to a lifting device via an eye
bolt or a lifting strap.
The axial piston unit can be transported suspended from an eye bolt screwed into
the drive shaft as long as only outward (pulling) axial forces are applied.
For all female threads, use a stud end from the same system of units and of the
correct size.
To do this, screw an eye bolt completely into the female thread on the drive shaft.
The thread size is indicated in the installation drawing.
Make sure that the eye bolt can bear the total weight of the axial piston unit plus 20%.
You can lift the axial piston unit as shown in Fig. 4 with the eye bolt screwed into the
drive shaft.
Fig. 4: Installing the eye bolt
wARNING! Danger from suspended loads!
During transport with a lifting strap, the axial piston unit can topple out of the lifting
strap and cause injury.
Use the widest possible lifting strap.
Make sure that the axial piston unit is securely fixed with the lifting strap.
Only guide the axial piston unit by hand for fine positioning and to avoid swinging.
Never stand or reach under suspended loads.
Place the lifting strap around the axial piston unit in such a way that it does not
pass over assembled parts (e.g., valves, piping) and that the axial piston unit is
not suspended from assembled parts (see Fig. 5).
Fig. 5: Transporting with lifting strap