Performing Flushing Cycle - Bosch Rexroth A10VSNO Instruction Manual

Axial piston variable pumps
Hide thumbs Also See for Rexroth A10VSNO:
Table of Contents

Advertisement

Changing connector
If necessary, you can change the position of the connector by turning the solenoid
position
body. This is independent of the connector version.
CAUTION! Hot surfaces on the solenoid!
Risk of burns!
To do this, proceed as follows:
2
1.
1
2.
3.
Tightening torque for
On axial piston units with a Hirschmann connector according to DIN EN 175 301-803-
Hirschmann connectors
A/ISO 4400, the following tightening torques apply when securing plug-in
connectors:
• Mounting bolt, M3 (1): 0.5 Nm
• Union nut M16 × 1.5 (2): 1.5–2.5 Nm
Fig. 15: HIRSCHMANN connector

7.5 Performing flushing cycle

In order to remove foreign particles from the system, Bosch Rexroth recommends a
flushing cycle for the entire system prior to initial commissioning. To avoid internal
contamination, do not include the axial piston unit in the flushing cycle.
Allow the solenoid to cool down sufficiently before touching it.
Wear heat-resistant protective clothing, e.g., gloves.
Loosen the mounting nut (1) of the solenoid. To do this, turn the mounting nut
(1) one turn counter-clockwise.
Turn the solenoid body (2) to the desired orientation.
Re-tighten the mounting nut. Tightening torque of the mounting nut: 5+1 Nm.
1
2
Use an additional flushing unit to perform the flushing cycle. Follow the
instructions of the flushing unit's manufacturer for the exact procedure during the
flushing cycle.
RE 92714-01-B/04.2018, A10VO, A10VSO, A10VSNO Series 32, Bosch Rexroth AG
Installation
41/60

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth a10voRexroth a10vvsoRexroth 32 series

Table of Contents