CAME PXC2 User Manual

CAME PXC2 User Manual

Security alarm control unit
Table of Contents

Advertisement

Quick Links

SECURITY ALARM CONTROL UNIT
FA01238-EN
PXC2-32 - PXC2-64 - PXC2-212
EN English
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PXC2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CAME PXC2

  • Page 1 SECURITY ALARM CONTROL UNIT FA01238-EN PXC2-32 - PXC2-64 - PXC2-212 EN English USER MANUAL...
  • Page 2: Table Of Contents

    USER MENU STRUCTURE ......CAME CONNECT FOR SECURITY SYSTEMS ..PAG.
  • Page 3: General Features

    In case of anomalies or false alarms, immediately contact your Installer. The maintenance of the system must be carried out by qua- The security alarm control unit PXC2 (PXC2-32, PXC2-64, PXC2- lified and trusted personnel (Installer); do not try to tamper with parts...
  • Page 4: Scenarios

    Scenarios The advantage of managing the systems through scenarios is to sim- plify the turning on of the areas to the User, in this way the manage- CELL PHONE ment is safe and fast. The scenarios are programmed by the installer and allow to: •...
  • Page 5: Code Properties Displaying

    CODE PROPERTIES DISPLAYING If this menu item is not displayed, it means that the User Code used to enter the menu is not enabled for this To display the code properties it is necessary to: management. Contact your Installer if you want to be Enter the User Menu.
  • Page 6: Codes Description Change

    CODES DESCRIPTION CHANGE With select and press (*). PROPERTIES ▲ ▼ With scroll through the code properties. ▲ ▼ To change the description of a code it is necessary to: indicates which areas of the system can be ASSOC. AREAS Enter the User Menu.
  • Page 7: Key Management

    With scroll through the code properties. ▲ ▼ Key management indicates which areas of the system can ASSOC. AREAS The keys can be managed by the User through a display keypad. be managed by the key. With # the area is managed However, the properties are set directly by the installer (to avoid pos- (associated), with - the area is not managed.
  • Page 8: System Management Through Display Keypad

    System management through display keypad SYSTEM STATUS INDICATIONS The LCD keypad The display can always be kept visible (LED and display visible) or The LCD keypad is the main control and display device for the secu- masked for greater safety (no information to outsiders on the system rity system.
  • Page 9: Display Icons

    DISPLAY ICONS Menu items Values [▲] [▼] Icon Meaning [*]-> Italiano - English ❶ KEYPAD LANGUAGE <-[#] CAME logo Français - Deutsch [▲] [▼] System activated ADDRESS [*]-> ADDRESS ❷ KEYPAD <- [#] N.--XX System not armed [▲] [▼] System partial armed [*]->...
  • Page 10: System Management Structure

    System Management Structure 11:23 01/02/10 Enter User Code ***-- Direct technical code, without user code ALARMS SILENCE #= exit D = turn off areas Technical code TECHNICAL MENU WAITING FOR COMMAND *=USER MENU A,B,C To start the User Menu scenario TURNING To interrupt Enter the user code...
  • Page 11: User Menu Structure

    User Menu Structure To access the user menu it is necessary to: type password (default ) and press (#). 123456 SYSTEM STATE ENTER THE CODE -------- ****** 123456 HH:MM DD/MM/YY EVENTS MENU EVENT DESCRIPTION DELETE ALARM MEMORY «EVENT DESCRIPTION» EVENTS MENU EVENTS FILTER «EVENT DESCRIPTION»...
  • Page 12: Turning On Through Scenarios

    Turning on through scenarios If in the of the technical menu the SPECIAL FUNCTIONS PRE-ARMING TEST has been enabled, in the case of existing anomalies in the system (no The areas are turned on by starting up scenarios. Scenarios are as- telephone line, no communication with at least one device in the sy- sociated with the buttons (A), (B), (C).
  • Page 13: Turning Off

    PARTIAL ARMING OF SCENARIO AREAS All temporarily excluded entrances will be included again To partially arm the areas turned on by a scenario, it is necessary to: when the associated areas are turned off. Enter the User Code on the keypad (necessary if the buttons 08:23 16/05/2010 (A), (B),...
  • Page 14: Security System Alarm

    A short message shows the clear description of the area. SIRENS ACTIVATION In the example, the button is pressed and the bedroom area in armed. A short message shows the clear description of the area. INTRUSION Press to start the new system configuration. ALARM 08:24 19/03/13...
  • Page 15: Fault

    ACTIVE ALARMS DISPLAYING Fault A fault can be caused by defective batteries (of the control unit, of Active alarms are the recent alarms which have not yet been restored the auxiliary power supplies or of the wireless devices) or by the lack to the alarm memory.
  • Page 16: Events History Displaying

    For each event, the following is displayed: Confirm the setting * and to change to cancel • TIME and DATE EXTENSION • EVENT DESCRIPTION (part 1) SET TIME? • EVENT INDEX (accessible with the button(*)) A=Edit 0=Cancel • EVENT DESCRIPTION (part 2) Only the turning-on operations programmed as "EXTENDA- To end the displaying press (#).
  • Page 17: 3G Signal Strength

    3G SIGNAL STRENGTH Once the entrance configuration to be tested has been se- lected, press to start the test. If there are no open entran- To check the 3G signal strength it is necessary to: ces, will be displayed, otherwise the list of open CLOSED ENTRANCES Enter the User Menu (User Code + (*)).
  • Page 18: Wireless Devices

    Control unit info Wireless devices The menu allows to view the wireless signal strength and the battery View information about the control unit: charge of the various wireless devices. Enter the User Menu (User Code + (*)). Enter the User Menu (User Code + (*)). With select and press (*).
  • Page 19: System Management By Key Reader

    System management by KEY READER The transponder key reader is the simplest control and display device System status displaying for the security system. With the transponder key reader it is possible to view the system It allows to: status through the indications given by its LEDs, as shown in the •...
  • Page 20: Turning On With Open Entrances

    TURNING ON WITH OPEN ENTRANCES Security alarm control unit In normal operation, it can happen to start a scenario with open en- An intrusion alarm is generated when a presence (radar) or opening trances (entrance door, dormer window, overhead door, ...). Some detector (contacts at windows and doors) detects an alarm status.
  • Page 21: Pxwrc Remote Control

    remote control. PXWRC remote control By default the button/scenario associations are the following: button 1 = scenario 1 button 2 = scenario 2 button 3 = scenario 3. If the scenario selected involves the arming of one or more areas with exit times other than zero, it is possible to reset the timing pressing the button for at least 5 seconds, after the launch of the scenario.
  • Page 22: Voice Guide Structure

    The voice guide plays the status of the system (off, partial, total) and of the currently active scenario (going out, staying at home, ...). Here Voice Guide Structure are the possible cases: CONTROL UNIT STATUS CODE AUTHENTICATION Button 1 Start scenario MAIN VOICE MENU Button 0 Turn off...
  • Page 23: System Status Check

    Press the button to return to the previous menu. System status check The area status play updating is carried out only at the end of To check the system status it is necessary to: the exit time; during this time the area status play does not change. Access the voice guide by telephone call and code recognition.
  • Page 24: Advanced Menu

    To consult the status, activate or deactivate the output it is necessary CALL INTERRUPTION Depending on the programming, the security control unit tries to call Access the voice guide by telephone call and code recognition. the phones more than once. Press the button to access the OUTPUTS...
  • Page 25: System Management Through Sms

    System management through SMS SMS management can be performed using your mobile phone. Receiving a phone call in the event of an alarm Through a special programming of the security control unit it is pos- In the event of an alarm or special events (faults, technological sible to: alarms, ...) the security control unit, if programmed, sends an SMS •...
  • Page 26: Sms Command Table

    SMS command table IN THE COMMAND REPLY Example of an SMS reply: Control unit 1#2X3#4U5#6#7#8#9#10#11#12#13#14#15#16#, Going out, Battery Fault, Network Present, Fuses OK CONTROL UNIT STATUS Control unit 1-2-3-4-5-6-7-8-9-10-11-12-13-14-15-16-,, Battery Ok, Network Absent, Control unit status query,  desc.CRSMS.654321.9000.  Faulty Fuses active scenario, battery, Where: 230Vac network, fuses;...
  • Page 27: Control Unit Management Through Came Domotic 3.0 App

    Control unit management through CAME Domotic 3.0 APP With the Came Domotic 3.0 App, it is possible to connect up securely to the control unit, check the status of each room, view video-cam ima- ges, activate scenarios, manage utilities, interact with your home from a remote location, on your smartphone, tablet or PC.
  • Page 28: Profile Management

    (gateway) that allows the system to be connected to the network. ❹ For CAME security systems the necessary gateway is 001SIGPRS - PXGPRS. Before continuing, you will need the identification code (keyco- de) that is printed on the tag affixed to the gateway.
  • Page 29: Confi Guration Options For Security Gateways

    ❿ This section allows to delegate the User for a set time or unlimi- tedly to provide remote assistance (via Came D Sw) and consequen- tly change the security system configuration options. ❶ Once registered, the gateway populates the list of registered de- ⓫ This section allows to delegate the User for a set time or unlimi-...
  • Page 30: App Description

    App DESCRIPTION PXC CONTROL UNIT 48 PXC CONTROL UNIT 48 Going out Going out Staying at home Staying at home Going to bed Going to bed Full disarm Full disarm INFORMATION INFORMATION The control unit is ready and not ar- The control unit is ready and not ar- med.
  • Page 31: Input

    The second ❷  and third pages contain the buttons needed to access PXC CONTROL UNIT 48 PXC CONTROL UNIT 48 the individual functions and settings relating to the system and the control unit displayed. Security scenarios Security scenarios Inputs Inputs Outputs Outputs Security scenarios...
  • Page 32 Activation of a scenario with open entrances excluded PXC48 CONTROL UNIT > Areas PXC48 CONTROL UNIT > Areas Touch the scenario you want to run ❹. Perimeter Perimeter CAUTION CAUTION Enter the correct activation code; if the code is valid you are taken Interrupt Interrupt There are open entrances,...
  • Page 33 Contents Areas PXC48 CONTROL UNIT > Areas PXC48 CONTROL UNIT > Areas Displaying the status of the areas Perimeter Perimeter This screen lets you view all the areas the security system has been Disarming Disarming divided into. Kitchen Kitchen total total If an authentication code is not entered only the status of the areas Bathrooms...
  • Page 34 Once the arming has started, only two buttons remain active. CONTROL UNIT PXC48 > Arming areas CONTROL UNIT PXC48 > Arming areas Perimeter Perimeter Cancel the current arming. Interrupt Interrupt Kitchen Kitchen arming arming Immediately arms the areas without respecting the exit time.
  • Page 35: Pxc48 Control Unit> Smith's House> Arming

    The icon is replicated at the top right of all the pages of the termi- PXC48 CONTROL UNIT > Areas PXC48 CONTROL UNIT > Areas nal and, once selected, it allows immediate access to the security Perimeter Perimeter section. Disarming Disarming Kitchen Kitchen...
  • Page 36 Contents Displaying the status of an area's entrances and exits PXC48 CONTROL UNIT> Living 2 PXC48 CONTROL UNIT> Living 2 Select one of the areas available to display the status of the entranc- es and exits that compose it. Input 7 Input 7 Disarming Disarming...
  • Page 37 Delete the changes made to the configuration and log out, to per- PXC48 CONTROL UNIT> Smith’s House> Arming PXC48 CONTROL UNIT> Smith’s House> Arming form new activations it is necessary to repeat the authentication. Arming one or more areas with one or more entrances open Garage 6 Garage 6 If you arm areas with open entrances, a pop-up appears warning you...
  • Page 38: Input 01

    A sensor with a camera able to acquire images in the event CONTROL UNIT PXC48 > All entrances arming CONTROL UNIT PXC48 > All entrances arming of activation is connected to the entrance; touching the Included Included Excluded Excluded Input 01 Input 01 icon triggers a photo shooting request.
  • Page 39 Declaration of conformity Came S.p.A. declares that this device conforms with the essential requirements and other pertinent provisions established by directives 1999/05/EC, 2006/95/EC and 2004/108/EC. An original copy of the declaration of conformity is available on request. The product also complies with the following product regulations EN 50131-3, EN 50131-4, EN 50131-5-3, EN 50131-6 Grade 2 EN 50130-5 Environmental class II.
  • Page 40 CAME S.p.A. Via Martiri Della Libertà, 15 31030 Dosson di Casier - Treviso - Italy tel. (+39) 0422 4940 - fax. (+39) 0422 4941...

This manual is also suitable for:

Pxc2-32Pxc2-64Pxc2- 212

Table of Contents