Installation

Electrical Connection

WARNING
Assembly and electrical connections must be carried out by qualified technician.
WARNING
Electrical Shock Hazard
Turn off power circuit at the service panel before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.
Failure to do so can result in death or electrical shock.
Connect ground wire to Green/Yellow ground wire in terminal box.
To protect you against electric shock, The Green/Yellow Wire must
be connected to the grounding wire in home electrical system.
Failure to do so can result in death or electrical shock.
It must under no circumstances be cut or removed.
Terminal
box cover
Terminal
box
18 English
9-1.
Disconnect power circuit
breaker.
9-2.
Remove terminal box cover.
E
F
A
B
C
D
A.
UL listed wire nuts
B.
Green (or bare) wire connected to
green/yellow wires
C.
White wires
D.
Black wires
E.
Home power supply cable
F.
UL/CSA approved strain relief
9-3.
Remove the strain relief hole
cover in the terminal box and
install a UL/CSA approved strain
relief.
9-4.
Run home power supply wiring
through strain relief into
terminal box.
9-5.
Use UL listed wire nuts and
connect white wires (C) together.
9-6.
Use UL listed wire nuts and
connect black wires (D) together.
9-7.
Connect green (or bare) ground
wire from home power supply
to the green/yellow ground wire
(B) in terminal box using UL
listed wire nuts.
9-8.
Tighten strain relief screw.