5.1

Application Status Command Class V1

Refer Z-Wave Management Command Class Specification
5.2

Application Busy Command

If a Z-Wave command to unlock or lock the deadbolt/lever while the keypad is active, the lock
responds with an Application Busy Command to indicate that it cannot currently process that
request. Note that other Z-Wave commands are processed normally even when the keypad
is active. The status sent is always 0x00 (try again later).
This command is sent when the lock was woken up by manual operation from its sleep state,
be it by keypad, Thumb turn, or inside logo button. The Busy status will be sent to Z-Wave
Controller till the local operation on the lock is in progress. However, Z-Wave Controller can
retry typically after 30 sec. after receiving the Application Busy Status.
5.3

Application Rejected Request Command

The lock would send the Application Reject Request Command in case of Z Wave Controller
trying to disable the Power Management (Battery Notifications) by Notification Command
Class as these notifications cannot be disabled.
5.4

Association Command Class V2

Refer Z-Wave Management Command Class Specification
Association Set Command:
This command is used to add destinations to a given association group.
This command MAY be ignored if the association group is already full.
Group Identifier: 0x01 (IDs other than 1 will be ignored by lock)
NodeID: List of Node IDs as assigned in the ZWave Network.
Association Remove:
This command is used to remove destinations from a given association group.
Group identifier: 0x01 (IDs other than 1 will be ignored by lock)
NodeID: Node IDs list as assigned in the ZWave Network.
Association Report:
This is sent as a response to Association Get command. Gives the list of nodes associated to the
corresponding association group.
Group identifier: 0x01 (It is reported as 0x01 irrespective of what is sent in Get command)
Max Nodes Supported: 0x02
Reports to follow: 0x00
Node ID: List of nodes as previously configured as a result of Set/Remove command.
Association Supported Groupings Report:
This command is used to advertise the maximum number of association groups implemented by this
node. This is sent as a response to Association Supported Groupings Get Command.
Supported Groupings: 0x01 (only lifeline group)
Association Specific Group Report:
This command is used to advertise the association group that represents the most recently detected
button. Group: 0x00 (Since this feature is not supported)