Time Command Class V1; User Code Command Class V1 - Schlage Z-Wave J Series Manual

Connected deadbolt and connected lever
Table of Contents

Advertisement

This is also used by lock for the reliable communication of the Unsolicited Reports and
Notifications communicated to the Z-Wave Controllers with S2 security for the communication
Controlling Command Class from the Lock are:
o
Battery
o
Configuration
o
Notification
o
User Code
o
Door Lock
o
Time
There will be 3 retries with 2 seconds intervals between each retry for the Unsolicited Report to be
sent with the Supervision Command Class
5.19

Time Command Class V1

Refer Z-Wave Application Command Class Specification
This Command Class has Support and Control provision on the lock.
The Time Command Class is required to provide the Network Time for the lock to support
the User Code Access Scheduling.
Note: At Power Up the Lock is assigned with Default Time and Date (00:00:00 , 1st Jan 1970)
and once the Lock is included in the secured Z Wave Network, it will use the Time Command
services to get the Network Controller Time. Lock will keep synchronizing every 24 Hrs. with
the Z-Wave Controller.
Refer Transport Service Command Class V2
Refer Z-Wave Transport- Service Command Class Specification
5.20

User Code Command Class V1

Refer Z-Wave Application Command Class Specification
The lock supports user codes between 4 and 8 digits in length. All the user codes in the
lock must be the same length and it may contain other length of user codes(4 to 8)
when added via Z-Wave plus controller application. This length is configurable with the
configuration command class.
If a user code is received that contains an improper number of digits (E.g.: if 3 digits user
code entered when the lock supports 4 to 8 digits) the lock returns a user ID status of
0xFE and does not modify the contents of that user code.
Note : The default User codes, and Programming codes are present in the lock
This Command Class is used to manage user codes in access control systems(Locks)
User code Set Command:
This command is used to set user code to the lock.
User Identifier: 1 to 30 (since our lock can store 30 user codes)
User ID Status: It follows the below table.